Continuous Blood Pressure Estimation Based on Multi-Scale Feature Extraction by the Neural Network With Multi-Task Learning
Open Access
- 6 May 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 883693
Abstract
In this article, a novel method for continuous blood pressure (BP) estimation based on multi-scale feature extraction by the neural network with multi-task learning (MST-net) has been proposed and evaluated. First, we preprocess the target (Electrocardiograph; Photoplethysmography) and label signals (arterial blood pressure), especially using peak-to-peak time limits of signals to eliminate the interference of the false peak. Then, we design a MST-net to extract multi-scale features related to BP, fully excavate and learn the relationship between multi-scale features and BP, and then estimate three BP values simultaneously. Finally, the performance of the developed neural network is verified by using a public multi-parameter intelligent monitoring waveform database. The results show that the mean absolute error ± standard deviation for systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) with the proposed method against reference are 4.04 ± 5.81, 2.29 ± 3.55, and 2.46 ± 3.58 mmHg, respectively; the correlation coefficients of SBP, DBP, and MAP are 0.96, 0.92, and 0.94, respectively, which meet the Association for the Advancement of Medical Instrumentation standard and reach A level of the British Hypertension Society standard. This study provides insights into the improvement of accuracy and efficiency of a continuous BP estimation method with a simple structure and without calibration. The proposed algorithm for BP estimation could potentially enable continuous BP monitoring by mobile health devices.Keywords
This publication has 44 references indexed in Scilit:
- Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care MonitoringIEEE Transactions on Biomedical Engineering, 2016
- Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity RatioIEEE Transactions on Biomedical Engineering, 2015
- Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and PracticeIEEE Transactions on Biomedical Engineering, 2015
- Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time2015
- Non-invasive continuous blood pressure monitoring: a review of current applicationsFrontiers of Medicine, 2013
- Optimal selection of wavelet basis function applied to ECG signal denoisingDigital Signal Processing, 2006
- European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurementJournal Of Hypertension, 2003
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- The influence of the sigmoid function parameters on the speed of backpropagation learning1995
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990