RESPIRATION-RELATED VARIATIONS IN CENTRAL VENOUS PRESSURE AS PREDICTORS OF FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING PATIENTS
Authors:
- 26 July 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Shock
- Vol. 60 (2) , 190-198
Abstract
Objective: The hemodynamic parameters used to accurately predict fluid responsiveness (FR) in spontaneously breathing patients (SB) require specific material and expertise. Measurements of the central venous pressure (CVP) are relatively simple and, importantly, are feasible in many critically ill patients. We analyzed the accuracy of respiration-related variations in CVP (vCVP) to predict FR in SB patients and examined the optimization of its measurement using a standardized, deep inspiratory maneuver. Patients and Methods: We performed a monocentric, prospective, diagnostic evaluation. Spontaneously breathing patients in intensive care units with a central venous catheter were prospectively included. The vCVP was measured while the patient was spontaneously breathing, both with (vCVP-st) and without (vCVP-ns) a standardized inspiratory maneuver, and calculated as: Minimum inspiratory v-wave peak pressure − Maximum expiratory v-wave peak pressure. A passive leg raising-induced increase in the left ventricular outflow tract velocity-time integral ≥10% defined FR. Results: Among 63 patients, 38 (60.3%) presented FR. The vCVP-ns was not significantly different between responders and nonresponders (−4.9 mm Hg [−7.5 to −3.1] vs. −4.1 mm Hg [−5.4 to 2.8], respectively; P = 0.15). The vCVP-st was lower in responders than nonresponders (−9.7 mm Hg [−13.9 to −6.2] vs. −3.6 mm Hg [−10.6 to −1.6], respectively; P = 0.004). A vCVP-st < −4.7 mm Hg predicted FR with 89.5% sensitivity, a specificity of 56.0%, and an area under the receiver operating characteristic curve of 0.72 (95% CI, 0.58 to 0.86) (P = 0.004). Conclusion: When a central venous catheter is present, elevated values for vCVP-st may be useful to identify spontaneously breathing patients unresponsive to volume expansion. Nevertheless, the necessity of performing a standardized, deep-inspiration maneuver may limit its clinical application.Keywords
This publication has 34 references indexed in Scilit:
- Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysisIntensive Care Medicine, 2016
- Fluid challenges in intensive care: the FENICE studyIntensive Care Medicine, 2015
- Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedsideCritical Care, 2012
- The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension*Critical Care Medicine, 2010
- Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis*Critical Care Medicine, 2010
- Passive leg raising for predicting fluid responsiveness: importance of the postural changeIntensive Care Medicine, 2008
- Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activityIntensive Care Medicine, 2007
- Ultrasonographic examination of the venae cavaeIntensive Care Medicine, 2006
- Heart rate control and mechanical cardiopulmonary coupling to assess central volume: a systems analysisAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2002
- The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEPJournal of Critical Care, 2001