Translating Minimally Invasive Glaucoma Surgery Devices
Open Access
- 30 September 2019
- journal article
- review article
- Published by Wiley in Clinical and Translational Science
- Vol. 13 (1) , 14-25
Abstract
Glaucoma is the leading cause of irreversible blindness with over 70 million people affected worldwide. The surgical management of glaucoma aims to lower intraocular pressure by increasing aqueous outflow facility. The latest manufacturing techniques have allowed for the development of a number of novel implantable devices to improve safety and outcomes of glaucoma surgery. These are collectively referred to as minimally invasive glaucoma surgery (MIGS) devices and are among the smallest devices implanted in the human body. This review discusses the design criterion and constraints as well as the user requirements for MIGS devices. We review how recent devices have attempted to meet these challenges and give our opinion as to the necessary characteristics for the development of future devices.Keywords
Funding Information
- Medical Research Council
This publication has 69 references indexed in Scilit:
- Clinical and morphological evaluation of gold micro shunt after unsuccessful surgical treatment of patients with primary open-angle glaucomaEye, 2013
- A Novel 8-mm Schlemm's Canal Scaffold Reduces Outflow Resistance in a Human Anterior Segment Perfusion ModelInvestigative Ophthalmology & Visual Science, 2013
- Postoperative Complications in the Tube Versus Trabeculectomy (TVT) Study During Five Years of Follow-upAmerican Journal of Ophthalmology, 2012
- Cutaneous and inflammatory response to long‐term percutaneous implants of sphere‐templated porous/solid poly(HEMA) and silicone in miceJournal of Biomedical Materials Research Part A, 2012
- Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised studyEye, 2012
- The first report on intermediate-term outcome of Ex-PRESS® glaucoma filtration device implanted under scleral flap in Japanese patientsClinical Ophthalmology, 2011
- Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucomaClinical Ophthalmology, 2011
- Aqueous Humor Dynamics: A ReviewThe Open Ophthalmology Journal, 2010
- Trabecular bypass stents decrease intraocular pressure in cultured human anterior segmentsAmerican Journal of Ophthalmology, 2004
- Cell and protein adhesion studies in glaucoma drainage device developmentBritish Journal of Ophthalmology, 1999