Richard M. H. Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard M. H. Lee has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Peng Tee Khaw
NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
5 shared publicationsSteve Brocchini
NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
5 shared publicationsYann Bouremel
NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
5 shared publicationsIan Eames
UCL Department of Mechanical Engineering, London, UK
4 shared publications- Amir Samsudin
Ophthalmology, University of Malaya Medical Centre, Kuala Lumpur, MYS
1 shared publication
Latest Publications
- Open Access
- 7 February 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 9 (3) , 15
Author Response: Ab Interno versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device
- 7 February 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 9 (3) , 15
Open AccessAuthor Response: Ab Interno versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device
- Open Access
- 30 September 2019
- Published by Wiley in Clinical and Translational Science
- Vol. 13 (1) , 14-25
Translating Minimally Invasive Glaucoma Surgery Devices
Glaucoma is the leading cause of irreversible blindness with over 70 million people affected worldwide. The surgical management of glaucoma aims to lower intraocular pressure by increasing aqueous outflow facility. The latest manufacturing techniques have allowed for the development of a number of novel implantable devices to improve safety and outcomes of glaucoma surgery. These are collectively referred to as minimally invasive glaucoma surgery (MIGS) devices and are among the smallest devices implanted in the human body. This review discusses the design criterion and constraints as well as the user requirements for MIGS devices. We review how recent devices have attempted to meet these challenges and give our opinion as to the necessary characteristics for the development of future devices.
- 30 September 2019
- Published by Wiley in Clinical and Translational Science
- Vol. 13 (1) , 14-25
Open AccessTranslating Minimally Invasive Glaucoma Surgery Devices
Glaucoma is the leading cause of irreversible blindness with over 70 million people affected worldwide. The surgical management of glaucoma aims to lower intraocular pressure by increasing aqueous outflow facility. The latest manufacturing techniques have allowed for the development of a number of novel implantable devices to improve safety and outcomes of glaucoma surgery. These are collectively referred to as minimally invasive glaucoma surgery (MIGS) devices and are among the smallest devices implanted in the human body. This review discusses the design criterion and constraints as well as the user requirements for MIGS devices. We review how recent devices have attempted to meet these challenges and give our opinion as to the necessary characteristics for the development of future devices.
- Open Access
- 1 May 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 8 (3) , 58
The Implications of an Ab Interno Versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device for Intraocular Pressure Control
Purpose: Minimally invasive glaucoma surgery (MIGS) devices that drain into the subconjunctival space can be inserted via an ab externo or ab interno approach. Limited experimental data exists as to the impact of either technique on intraocular pressure (IOP) control. We performed microfluidic studies by using ex vivo rabbit eyes to assess the effect of each approach on outflow resistance of a subconjunctival drainage device for IOP control. Methods: A microfluidic experiment system was designed, consisting of a controlled reservoir of water connected to a pressure pump/flow sensor. The flow rate of water was fixed at 2 μl/min to simulate aqueous humor production. The pressure readings for each approach were recorded at a frequency of 1 Hz. A baseline reading was made before tube insertion into the eye (PEEK tube length set to aim for an initial outflow resistance of 5 to 10 mm Hg/μL/min) followed by measurements for a cumulative 2-ml volume entering the subconjunctival space. Results were adjusted for water viscosity at 37°C and reported as outflow resistance (mm Hg/μL/min ± standard error of mean). Results: Outflow resistance via the ab interno approach was 90.4% higher than with the ab externo approach being measured at 0.80 ± 0.11 mm Hg/μL/min and 0.42 ± 0.05 mm Hg/μL/min, respectively. Bleb formation was observed to be less predictable with the ab interno approach. Conclusions: The ab interno approach demonstrated greater outflow resistance and less predictable bleb formation than the ab externo approach. These results have implications for long-term IOP control and success depending on the approach to device insertion and could be an important consideration for future MIGS devices. Translational Relevance: The effect of the ab interno versus ab externo approach of a MIGS device inserted into the subconjunctival space was assessed. The ab interno approach demonstrated greater outflow resistance and less predictable bleb formation that may have implications for the development of future MIGS devices.
- 1 May 2019
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 8 (3) , 58
Open AccessThe Implications of an Ab Interno Versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device for Intraocular Pressure Control
Purpose: Minimally invasive glaucoma surgery (MIGS) devices that drain into the subconjunctival space can be inserted via an ab externo or ab interno approach. Limited experimental data exists as to the impact of either technique on intraocular pressure (IOP) control. We performed microfluidic studies by using ex vivo rabbit eyes to assess the effect of each approach on outflow resistance of a subconjunctival drainage device for IOP control. Methods: A microfluidic experiment system was designed, consisting of a controlled reservoir of water connected to a pressure pump/flow sensor. The flow rate of water was fixed at 2 μl/min to simulate aqueous humor production. The pressure readings for each approach were recorded at a frequency of 1 Hz. A baseline reading was made before tube insertion into the eye (PEEK tube length set to aim for an initial outflow resistance of 5 to 10 mm Hg/μL/min) followed by measurements for a cumulative 2-ml volume entering the subconjunctival space. Results were adjusted for water viscosity at 37°C and reported as outflow resistance (mm Hg/μL/min ± standard error of mean). Results: Outflow resistance via the ab interno approach was 90.4% higher than with the ab externo approach being measured at 0.80 ± 0.11 mm Hg/μL/min and 0.42 ± 0.05 mm Hg/μL/min, respectively. Bleb formation was observed to be less predictable with the ab interno approach. Conclusions: The ab interno approach demonstrated greater outflow resistance and less predictable bleb formation than the ab externo approach. These results have implications for long-term IOP control and success depending on the approach to device insertion and could be an important consideration for future MIGS devices. Translational Relevance: The effect of the ab interno versus ab externo approach of a MIGS device inserted into the subconjunctival space was assessed. The ab interno approach demonstrated greater outflow resistance and less predictable bleb formation that may have implications for the development of future MIGS devices.
- 1 May 2019
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 28 (5) , e75-e76
A Case Report of Complete Blockage of a Baerveldt Glaucoma Implant Following Insertion of a 3-0 Supramid Suture
Purpose: The aim of this study was to present a case of a Baerveldt glaucoma implant lumen being completely occluded with a 3-0 Supramid stent suture. Patient and Methods: The patient underwent Baerveldt glaucoma implant surgery with placement of an intraluminal 3-0 Supramid stent suture that acts to restrict flow across the device and reduce the risk of postoperative hypotony. Following suturing of the implant to the sclera, the device was flow tested. No flow was observed through the device tube and a significant ballooning of the tube diameter occurred with increased pressure on the device. The device was explanted from the eye and replaced with a different implant without further postoperative complication. The explanted device was assessed using custom microfluidic equipment in an in vitro environment. Results: This phenomenon occurred despite using several different batches of the 3-0 Supramid stent suture and the device had to be removed and replaced with another device without complication. In vitro microfluidic assessment of the device demonstrated no flow across the device tube despite over 150 mm Hg of pressure being exerted on the device. Conclusions: We hypothesize that the blockage occurred at the junction between the device tube and plate and that the ballooning phenomenon observed was due to a defect in the tube wall. This case highlights the importance of flow testing all glaucoma drainage devices before insertion given the variation in manufacturing conditions to avoid the risk of intraoperative complications.
- 1 May 2019
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 28 (5) , e75-e76
A Case Report of Complete Blockage of a Baerveldt Glaucoma Implant Following Insertion of a 3-0 Supramid Suture
Purpose: The aim of this study was to present a case of a Baerveldt glaucoma implant lumen being completely occluded with a 3-0 Supramid stent suture. Patient and Methods: The patient underwent Baerveldt glaucoma implant surgery with placement of an intraluminal 3-0 Supramid stent suture that acts to restrict flow across the device and reduce the risk of postoperative hypotony. Following suturing of the implant to the sclera, the device was flow tested. No flow was observed through the device tube and a significant ballooning of the tube diameter occurred with increased pressure on the device. The device was explanted from the eye and replaced with a different implant without further postoperative complication. The explanted device was assessed using custom microfluidic equipment in an in vitro environment. Results: This phenomenon occurred despite using several different batches of the 3-0 Supramid stent suture and the device had to be removed and replaced with another device without complication. In vitro microfluidic assessment of the device demonstrated no flow across the device tube despite over 150 mm Hg of pressure being exerted on the device. Conclusions: We hypothesize that the blockage occurred at the junction between the device tube and plate and that the ballooning phenomenon observed was due to a defect in the tube wall. This case highlights the importance of flow testing all glaucoma drainage devices before insertion given the variation in manufacturing conditions to avoid the risk of intraoperative complications.
- 1 December 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (13) , 8026
Dimensional and Flow Properties of the EX-PRESS Glaucoma Drainage Device
- 1 December 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (13) , 8026
Dimensional and Flow Properties of the EX-PRESS Glaucoma Drainage Device