Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancer
Authors:
- Phillip TaddeiPTPhillip Taddei
- Yuanshui ZhengYZYuanshui Zheng
- Dragan MirkovicDMDragan Mirkovic
- Thomas JordanTJThomas Jordan
- Wayne NewhauserWNWayne Newhauser
- 29 February 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (6) , 1677-1688
Abstract
Proton therapy reduces the integral therapeutic dose required for local control in prostate patients compared to intensity-modulated radiotherapy. One proposed benefit of this reduction is an associated decrease in the incidence of radiogenic secondary cancers. However, patients are also exposed to stray radiation during the course of treatment. The purpose of this study was to quantify the stray radiation dose received by patients during proton therapy for prostate cancer. Using a Monte Carlo model of a proton therapy nozzle and a computerized anthropomorphic phantom, we determined that the effective dose from stray radiation per therapeutic dose (E/D) for a typical prostate patient was approximately 5.5 mSv Gy(-1). Sensitivity analysis revealed that E/D varied by +/-30% over the interval of treatment parameter values used for proton therapy of the prostate. Equivalent doses per therapeutic dose (HT/D) in specific organs at risk were found to decrease with distance from the isocenter, with a maximum of 12 mSv Gy(-1) in the organ closest to the treatment volume (bladder) and 1.9 mSv Gy(-1) in the furthest (esophagus). Neutrons created in the nozzle predominated effective dose, though neutrons created in the patient contributed substantially to the equivalent dose in organs near the proton field. Photons contributed less than 15% to equivalent doses.Keywords
This publication has 39 references indexed in Scilit:
- The Impact of Protons on the Incidence of Second Malignancies in RadiotherapyTechnology in Cancer Research & Treatment, 2007
- Spread‐out Bragg peak and monitor units calculation with the Monte Carlo Code MCNPXMedical Physics, 2007
- Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for , , and beam energiesMedical Physics, 2006
- Design tools for proton therapy nozzles based on the double-scattering foil techniqueRadiation Protection Dosimetry, 2005
- Experience With Conformal Proton Therapy for Early Prostate CancerAmerican Journal of Clinical Oncology, 2004
- Henry S. Kaplan Distinguished Scientist Award 2003The crooked shall be made straight; dose–response relationships for carcinogenesisInternational Journal of Radiation Biology, 2004
- Second malignancies in prostate carcinoma patients after radiotherapy compared with surgeryCancer, 2000
- Cross-Section Evaluations to 150 MeV for Accelerator-Driven Systems and Implementation in MCNPXNuclear Science and Engineering, 1999
- Secondary neutron and photon dose in proton therapyRadiotherapy and Oncology, 1998
- SPAR, a FORTRAN program for computing stopping powers and ranges for muons, charged pions, protons, and heavy ions1973