Spread‐out Bragg peak and monitor units calculation with the Monte Carlo Code MCNPX
Authors:
- J. HéraultJHJ. Hérault
- N. IborraNIN. Iborra
- B. SerranoBSB. Serrano
- P. ChauvelPCP. Chauvel
- 26 January 2007
- journal article
- Published by Wiley in Medical Physics
- Vol. 34 (2) , 680-688
Abstract
The aim of this work was to study the dosimetric potential of the Monte Carlo code MCNPX applied to the protontherapy field. For series of clinical configurations a comparison between simulated and experimental data was carried out, using the proton beam line of the MEDICYC isochronous cyclotron installed in the Centre Antoine Lacassagne in Nice. The dosimetric quantities tested were depth-dose distributions, output factors, and monitor units. For each parameter, the simulation reproduced accurately the experiment, which attests the quality of the choices made both in the geometrical description and in the physics parameters for beam definition. These encouraging results enable us today to consider a simplification of quality control measurements in the future. Monitor Units calculation is planned to be carried out with preestablished Monte Carlo simulation data. The measurement, which was until now our main patient dose calibration system, will be progressively replaced by computation based on the MCNPX code. This determination of Monitor Units will be controlled by an independent semi-empirical calculation.Keywords
This publication has 17 references indexed in Scilit:
- Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fieldsPhysics in Medicine & Biology, 2006
- Virtual commissioning of a treatment planning system for proton therapy of ocular cancersRadiation Protection Dosimetry, 2005
- The prediction of output factors for spread-out proton Bragg peak fields in clinical practicePhysics in Medicine & Biology, 2005
- Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beamsPhysics in Medicine & Biology, 2005
- 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometryPhysics in Medicine & Biology, 2005
- Dosimetry for ocular proton beam therapy at the Harvard Cyclotron Laboratory based on the ICRU Report 59Medical Physics, 2002
- An analytical approximation of depth - dose distributions for therapeutic proton beamsPhysics in Medicine & Biology, 1996
- The depth-dependent radiation response of human melanoma cells exposed to 65 MeV protonsBritish Journal of Radiology, 1994