Seismic Performance of Story-Added Type Buildings Remodeled with Story Seismic Isolation Systems
Open Access
Abstract
Story-added type apartments have recently been introduced as an option to resolve the housing supply shortage in areas that are undergoing rapid industrialization and urbanization. However, the infrastructure of old apartment buildings (>20 years old) makes it difficult to introduce convenient facilities and recent technologies such as those involving the Internet of Things and augmented realities. Applying housing technologies to existing older apartments can increase housing supply and potentially address the aforementioned issues. However, story-added building remodeling increases the weight of existing buildings, necessitating seismic reinforcement, which is the major obstacle when performing vertical building extensions. This study presents methods for lowering seismic loads associated with vertical augmentation of buildings while improving the seismic performance. A model of a vertically extended building with three additional stories constructed on top of an existing 15-story apartment building was used. The applied seismic isolation system decreased the maximum response acceleration on top of the remodeled building by approximately 70% and 65% in the X-direction and Y-direction, respectively, while decreasing the base shear plane by approximately 30% in both the X- and Y-directions in comparison with forces on a non-seismically isolated building. These results demonstrate that the use of a seismic isolation system can significantly reduce seismic loads.Keywords
Funding Information
- Dankook University (The present research was conducted by the research fund of Dankook University in 2019)
This publication has 5 references indexed in Scilit:
- Multi-Directional Base Isolation System for Coupled Horizontal and Vertical Seismic ExcitationsJournal of Earthquake Engineering, 2020
- Experimental realisation of the real‐time controlled smart magnetorheological elastomer seismic isolation system with shake tableStructural Control and Health Monitoring, 2019
- Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation DeviceJournal of the Korean Association for Spatial Structures, 2018
- Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation SystemJournal of the Korean Association for Spatial Structures, 2017
- Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete BuildingsInternational Journal of Concrete Structures and Materials, 2015