MHMoo-Won Hur

Moo-Won Hur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Moo-Won Hur has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance Evaluation of Torque-Controlled Expansion Anchors with Improved Sleeve and Header Details

    by Moo-Won Hur, Kyoung-Hun Chae, Hyun-Ho Lee, Tae-Won Park

    This study assesses improvements in the head and extension sleeve parts for a post-installed anchor. The sleeve and head details were proposed to enhance the structural performance of the post-installed anchor, and the optimal structural shape was determined through finite element analysis. The analysis results revealed that the anchor's performance was most efficiently improved when the sleeve length was 9.0 mm and the head length was 3.0 mm. In the model with these dimensions applied, the performance improved approximately 1.71 times compared to the existing model, validating the effectiveness of the proposed structural details. The improved pull-out strength test of anchor diameter M12 showed an increase of 1.25 times in normal-strength concrete and 1.28 times in high-strength concrete, with an embedded depth of 50 mm. The improved pull-out strength test of anchor diameter M16 showed that the pull-out strength increased by 1.42 times for normal-strength concrete and about 1.33 times for high-strength concrete. This research proposes a modified equation that reflects changes in the effective embedded depth and diameter. A comparison of the proposed equation with that of European Technical Approval Guideline (ETAG) showed that the correlation coefficient changed from 0.908 to 0.962, and the coefficient of variation changed from 18.9 to 10.4%, meaning that the proposed equation reflected the actual experimental values more accurately.


  • Open Access

    Seismic Performance of Story-Added Type Buildings Remodeled with Story Seismic Isolation Systems

    by Moo-Won Hur, Tae-Won Park

    Story-added type apartments have recently been introduced as an option to resolve the housing supply shortage in areas that are undergoing rapid industrialization and urbanization. However, the infrastructure of old apartment buildings (>20 years old) makes it difficult to introduce convenient facilities and recent technologies such as those involving the Internet of Things and augmented realities. Applying housing technologies to existing older apartments can increase housing supply and potentially address the aforementioned issues. However, story-added building remodeling increases the weight of existing buildings, necessitating seismic reinforcement, which is the major obstacle when performing vertical building extensions. This study presents methods for lowering seismic loads associated with vertical augmentation of buildings while improving the seismic performance. A model of a vertically extended building with three additional stories constructed on top of an existing 15-story apartment building was used. The applied seismic isolation system decreased the maximum response acceleration on top of the remodeled building by approximately 70% and 65% in the X-direction and Y-direction, respectively, while decreasing the base shear plane by approximately 30% in both the X- and Y-directions in comparison with forces on a non-seismically isolated building. These results demonstrate that the use of a seismic isolation system can significantly reduce seismic loads.