Variability of the penetration of particles through facemasks
- 16 December 2021
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 56 (2) , 186-203
Abstract
COVID-19 is transmitted, at least in part, by airborne particles emitted by infected individuals. Wearing masks is one of the key actions that are required to prevent spreading COVID-19. To understand the variability in the performance, we evaluated the material performance of the whole mask, as manufactured, in terms of the penetration of particles, comfort and the quality factor of multiple copies of 29 different types. All masks were mounted to prevent leakage around the edges so the mask material and manufacture was tested, but the effects of the fit were not considered. The results of this study thus represent the upper bound of the performance of facemasks since leakage around the edges due to poor fit often overwhelms filtration through the mask material. The tests were performed at a steady flow rate of 30 L/min; mean values of the performance parameters were calculated for two different sizes; 0.12 µm and 0.3 µm. Of the masks tested, for 0.12 µm particles, N95 face filtering respirators consistently had the lowest peak penetration 1.7 ± 0.5%, while KN95 masks allowed 3.7 ± 2.6% penetration. In contrast, penetration through pleated procedure masks was 14.7 ± 16.9% due to one outlier - with that outlier removed, penetration decreased to 7.1 ± 4.3%; cloth masks allowed 26.4 ± 9.3% penetration. Tests on multiple copies of different masks demonstrated consistent performance of N95s, but considerably greater variability within the other classes of masks tested, leading to uncertainty in the degree of protection that they would provide.Keywords
This publication has 45 references indexed in Scilit:
- Factors Affecting Filter Penetration and Quality Factor of Particulate RespiratorsAerosol and Air Quality Research, 2013
- Native Morphology of Influenza VirionsFrontiers in Microbiology, 2012
- Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected SubjectsJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2011
- Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle PenetrationJournal of Occupational and Environmental Hygiene, 2009
- N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic FlowJournal of Occupational and Environmental Hygiene, 2008
- Influenza Virus in Human Exhaled Breath: An Observational StudyPLOS ONE, 2008
- Manikin-Based Performance Evaluation of N95 Filtering-Facepiece Respirators Challenged with NanoparticlesAnnals of Occupational Hygiene, 2005
- Coefficient of Variation2005
- Aerosol penetration through surgical masksAmerican Journal of Infection Control, 1992
- On the stationary charge distribution on aerosol particles in a bipolar ionic atmosphereGeofisica pura e applicata, 1963