Stavros Amanatidis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stavros Amanatidis has a total of 233 co-authors. Here are the top co-authors by number of shared publications:
- Richard C. Flagan
California Institute of Technology, Pasadena, CA 91125, USA
19 shared publications - Susanne Hering
Aerosol Dynamics Inc., Berkeley, CA 94710, USA
15 shared publications - Yuanlong Huang
Ningbo Institute of Digital Twin, Eastern Institute of Technology, Ningbo 315201, China
15 shared publications Benjamin C. Schulze
Department of Environmental Science and Engineering, California Institute of Technology, Pasadena, CA 91125, USA
14 shared publications- John H. Seinfeld
California Institute of Technology
14 shared publications - Leonidas Ntziachristos
Aristotle University of Thessaloniki
11 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Design and development of a high-throughput multipattern aerosol deposition device for respiratory toxicity and health-risk assessment (MARTHA)
In vitro toxicity assessments of aerosols are often limited by their physiological relevance. Conventional aerosol exposure systems provide uniform particle deposition, whereas in vivo deposition is inherently heterogeneous across lung regions. To address this, we have developed a high-throughput Multipattern Aerosol deposition device for Respiratory Toxicity and Health-risk Assessment (MARTHA). MARTHA employs laminar-flow, water-based condensation technology to efficiently grow nanoparticles from as small as 5 nm to > 3 µm while maintaining physiological conditions in the lungs (37 °C, ≥95% humidity). A key innovation is its ability to generate both uniform and non-uniform deposition patterns using three distinct nozzle configurations (3-jets, Slit, and 7-jets). Deposition validation using aerosolized sodium fluorescein demonstrated consistent particle dose distribution across nozzle types, with a low coefficient of variation (CoV 95%) for particle number concentrations ranging from 2,000–200,000 #/cm3 and enabled simultaneous exposure of cells at the air-liquid interface (ALI) in 12 Transwell inserts. Exposure of aerosolized e-liquid to A549 cells at the ALI resulted in significant differences in trans-epithelial electrical resistance (TEER), underscoring the impact of deposition patterns. Overall, MARTHA is an advanced in vitro platform that more realistically mimics the pulmonary deposition of aerosols compared to existing systems while enabling a high-throughput evaluation of aerosol toxicity.
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign and development of a high-throughput multipattern aerosol deposition device for respiratory toxicity and health-risk assessment (MARTHA)
In vitro toxicity assessments of aerosols are often limited by their physiological relevance. Conventional aerosol exposure systems provide uniform particle deposition, whereas in vivo deposition is inherently heterogeneous across lung regions. To address this, we have developed a high-throughput Multipattern Aerosol deposition device for Respiratory Toxicity and Health-risk Assessment (MARTHA). MARTHA employs laminar-flow, water-based condensation technology to efficiently grow nanoparticles from as small as 5 nm to > 3 µm while maintaining physiological conditions in the lungs (37 °C, ≥95% humidity). A key innovation is its ability to generate both uniform and non-uniform deposition patterns using three distinct nozzle configurations (3-jets, Slit, and 7-jets). Deposition validation using aerosolized sodium fluorescein demonstrated consistent particle dose distribution across nozzle types, with a low coefficient of variation (CoV 95%) for particle number concentrations ranging from 2,000–200,000 #/cm3 and enabled simultaneous exposure of cells at the air-liquid interface (ALI) in 12 Transwell inserts. Exposure of aerosolized e-liquid to A549 cells at the ALI resulted in significant differences in trans-epithelial electrical resistance (TEER), underscoring the impact of deposition patterns. Overall, MARTHA is an advanced in vitro platform that more realistically mimics the pulmonary deposition of aerosols compared to existing systems while enabling a high-throughput evaluation of aerosol toxicity.
- Open Access
- 15 January 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (1) , 197-210
Fast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)
New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.
- 15 January 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (1) , 197-210
Open AccessFast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)
New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.
- Open Access
- 18 September 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Fast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)
New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth’s radiative balance as it produces roughly half of global cloud condensation nuclei. However, time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub‑3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods were tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPS) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.
- 18 September 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-22
Open AccessFast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)
New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth’s radiative balance as it produces roughly half of global cloud condensation nuclei. However, time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub‑3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods were tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPS) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.
- 15 December 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 382 (6676) , 1308-1314
Iodine oxoacids enhance nucleation of sulfuric acid particles in the atmosphere
The main nucleating vapor in the atmosphere is thought to be sulfuric acid (H 2 SO 4 ), stabilized by ammonia (NH 3 ). However, in marine and polar regions, NH 3 is generally low, and H 2 SO 4 is frequently found together with iodine oxoacids [HIO x , i.e., iodic acid (HIO 3 ) and iodous acid (HIO 2 )]. In experiments performed with the CERN CLOUD (Cosmics Leaving OUtdoor Droplets) chamber, we investigated the interplay of H 2 SO 4 and HIO x during atmospheric particle nucleation. We found that HIO x greatly enhances H 2 SO 4 (-NH 3 ) nucleation through two different interactions. First, HIO 3 strongly binds with H 2 SO 4 in charged clusters so they drive particle nucleation synergistically. Second, HIO 2 substitutes for NH 3 , forming strongly bound H 2 SO 4 -HIO 2 acid-base pairs in molecular clusters. Global observations imply that HIO x is enhancing H 2 SO 4 (-NH 3 ) nucleation rates 10- to 10,000-fold in marine and polar regions.
- 15 December 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 382 (6676) , 1308-1314
Iodine oxoacids enhance nucleation of sulfuric acid particles in the atmosphere
The main nucleating vapor in the atmosphere is thought to be sulfuric acid (H 2 SO 4 ), stabilized by ammonia (NH 3 ). However, in marine and polar regions, NH 3 is generally low, and H 2 SO 4 is frequently found together with iodine oxoacids [HIO x , i.e., iodic acid (HIO 3 ) and iodous acid (HIO 2 )]. In experiments performed with the CERN CLOUD (Cosmics Leaving OUtdoor Droplets) chamber, we investigated the interplay of H 2 SO 4 and HIO x during atmospheric particle nucleation. We found that HIO x greatly enhances H 2 SO 4 (-NH 3 ) nucleation through two different interactions. First, HIO 3 strongly binds with H 2 SO 4 in charged clusters so they drive particle nucleation synergistically. Second, HIO 2 substitutes for NH 3 , forming strongly bound H 2 SO 4 -HIO 2 acid-base pairs in molecular clusters. Global observations imply that HIO x is enhancing H 2 SO 4 (-NH 3 ) nucleation rates 10- to 10,000-fold in marine and polar regions.
- 16 December 2021
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 56 (2) , 186-203
Variability of the penetration of particles through facemasks
COVID-19 is transmitted, at least in part, by airborne particles emitted by infected individuals. Wearing masks is one of the key actions that are required to prevent spreading COVID-19. To understand the variability in the performance, we evaluated the material performance of the whole mask, as manufactured, in terms of the penetration of particles, comfort and the quality factor of multiple copies of 29 different types. All masks were mounted to prevent leakage around the edges so the mask material and manufacture was tested, but the effects of the fit were not considered. The results of this study thus represent the upper bound of the performance of facemasks since leakage around the edges due to poor fit often overwhelms filtration through the mask material. The tests were performed at a steady flow rate of 30 L/min; mean values of the performance parameters were calculated for two different sizes; 0.12 µm and 0.3 µm. Of the masks tested, for 0.12 µm particles, N95 face filtering respirators consistently had the lowest peak penetration 1.7 ± 0.5%, while KN95 masks allowed 3.7 ± 2.6% penetration. In contrast, penetration through pleated procedure masks was 14.7 ± 16.9% due to one outlier - with that outlier removed, penetration decreased to 7.1 ± 4.3%; cloth masks allowed 26.4 ± 9.3% penetration. Tests on multiple copies of different masks demonstrated consistent performance of N95s, but considerably greater variability within the other classes of masks tested, leading to uncertainty in the degree of protection that they would provide.
- 16 December 2021
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 56 (2) , 186-203
Variability of the penetration of particles through facemasks
COVID-19 is transmitted, at least in part, by airborne particles emitted by infected individuals. Wearing masks is one of the key actions that are required to prevent spreading COVID-19. To understand the variability in the performance, we evaluated the material performance of the whole mask, as manufactured, in terms of the penetration of particles, comfort and the quality factor of multiple copies of 29 different types. All masks were mounted to prevent leakage around the edges so the mask material and manufacture was tested, but the effects of the fit were not considered. The results of this study thus represent the upper bound of the performance of facemasks since leakage around the edges due to poor fit often overwhelms filtration through the mask material. The tests were performed at a steady flow rate of 30 L/min; mean values of the performance parameters were calculated for two different sizes; 0.12 µm and 0.3 µm. Of the masks tested, for 0.12 µm particles, N95 face filtering respirators consistently had the lowest peak penetration 1.7 ± 0.5%, while KN95 masks allowed 3.7 ± 2.6% penetration. In contrast, penetration through pleated procedure masks was 14.7 ± 16.9% due to one outlier - with that outlier removed, penetration decreased to 7.1 ± 4.3%; cloth masks allowed 26.4 ± 9.3% penetration. Tests on multiple copies of different masks demonstrated consistent performance of N95s, but considerably greater variability within the other classes of masks tested, leading to uncertainty in the degree of protection that they would provide.
- Open Access
- 9 August 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (8) , 5429-5445
The nano-scanning electrical mobility spectrometer (nSEMS) and its application to size distribution measurements of 1.5–25 nm particles
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol–cloud interactions. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a novel differential mobility analyzer and a two-stage condensation particle counter (CPC). The mobility analyzer, a radial opposed-migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution and diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGIC™ water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high-time- and size-resolution measurement of nanoparticles and can capture the critical aerosol dynamics of newly formed atmospheric particles. Using a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency as a charge conditioner, the nSEMS has enabled measurement of the contributions of both neutral and ion-mediated nucleation to new particle formation.
- 9 August 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (8) , 5429-5445
Open AccessThe nano-scanning electrical mobility spectrometer (nSEMS) and its application to size distribution measurements of 1.5–25 nm particles
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol–cloud interactions. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a novel differential mobility analyzer and a two-stage condensation particle counter (CPC). The mobility analyzer, a radial opposed-migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution and diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGIC™ water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high-time- and size-resolution measurement of nanoparticles and can capture the critical aerosol dynamics of newly formed atmospheric particles. Using a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency as a charge conditioner, the nSEMS has enabled measurement of the contributions of both neutral and ion-mediated nucleation to new particle formation.
- Open Access
- 18 June 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (6) , 4507-4516
Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements
Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.
- 18 June 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (6) , 4507-4516
Open AccessEfficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements
Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.
- Open Access
- 3 June 2021
- Published by Copernicus GmbH
- p. 1-26
Reply on RC2
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol-cloud interaction. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a charge conditioner, a novel differential mobility analyzer, and a two-stage condensation particle counter (CPC). The charge conditioner employs a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency. The mobility analyzer, a radial opposed migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution or diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the charge conditioner and mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGICTM water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high time and size resolution measurement of nanoparticles, and can capture the critical aerosol dynamics of newly formed atmospheric particles.
- 3 June 2021
- Published by Copernicus GmbH
- p. 1-26
Open AccessReply on RC2
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol-cloud interaction. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a charge conditioner, a novel differential mobility analyzer, and a two-stage condensation particle counter (CPC). The charge conditioner employs a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency. The mobility analyzer, a radial opposed migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution or diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the charge conditioner and mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGICTM water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high time and size resolution measurement of nanoparticles, and can capture the critical aerosol dynamics of newly formed atmospheric particles.
- Open Access
- 3 June 2021
- Published by Copernicus GmbH
- p. 1-26
Reply on RC1
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol-cloud interaction. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a charge conditioner, a novel differential mobility analyzer, and a two-stage condensation particle counter (CPC). The charge conditioner employs a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency. The mobility analyzer, a radial opposed migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution or diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the charge conditioner and mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGICTM water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high time and size resolution measurement of nanoparticles, and can capture the critical aerosol dynamics of newly formed atmospheric particles.
- 3 June 2021
- Published by Copernicus GmbH
- p. 1-26
Open AccessReply on RC1
Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol-cloud interaction. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a charge conditioner, a novel differential mobility analyzer, and a two-stage condensation particle counter (CPC). The charge conditioner employs a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency. The mobility analyzer, a radial opposed migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution or diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the charge conditioner and mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGICTM water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high time and size resolution measurement of nanoparticles, and can capture the critical aerosol dynamics of newly formed atmospheric particles.