Platelet aggregation monitoring with a newly developed quartz crystal microbalance system as an alternative to optical platelet aggregometry
Authors:
- 29 September 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (11) , 2930-2938
Abstract
The objective of this study was to establish a new test system for the monitoring of platelet aggregation during extracorporeal circulation (ECC) procedures. Even though extensive progress has been made in improving the haemocompatibility of extracorporeal circulation devices, activation of blood coagulation, blood platelets and inflammatory responses are still undesired outcomes of cardiopulmonary bypass. This study deals with an approach towards a platelet aggregation measuring system using a newly developed quartz crystal microbalance (QCM) system. Since QCM is a rarely used technique in the field of blood analytics, the challenge was to transfer the well established methods of aggregometry to the new test system. In a QCM system, either bare gold or fibrinogen-coated sensors were incubated with ADP or arachidonic acid (AA) stimulated platelet rich plasma. For negative controls the GPIIb/IIIa inhibitory antibody abciximab (Reopro®) was used as an inhibitor of platelet aggregation. During incubation, the frequency shifts of the sensors were recorded. The results gained from the QCM system were compared to results gained by optical platelet aggregometry (born aggregometry). For additional visualization of platelet adhesion to the sensor surfaces, fluorescent microscopy and scanning electron microscopy were used. The QCM sensor was able to detect platelet aggregation in both uncoated and fibrinogen coated sensors. The measuring curves of aggregation measurements and controls were clearly distinguishable from each other in terms of frequency shifts and kinetics. For aggregation measurements and inhibited controls the therapeutic diagnosis of platelet function is identical between aggregometer and QCM data. In future, QCM based measuring devices may become an alternative to established point of care methods for rapid bedside testing of platelet aggregation.Keywords
This publication has 28 references indexed in Scilit:
- Multidisciplinary Approach to the Challenge of HemostasisAnesthesia & Analgesia, 2010
- The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogenBiomaterials, 2010
- Investigation of Prothrombin Time in Human Whole-Blood Samples with a Quartz Crystal BiosensorAnalytical Chemistry, 2009
- Synthetic receptors for selectively detecting erythrocyte ABO subgroupsAnalytica Chimica Acta, 2009
- Aspirin in the primary and secondary prevention of vascular disease: collaborative meta-analysis of individual participant data from randomised trialsThe Lancet, 2009
- Tetraglyme coatings reduce fibrinogen and von Willebrand factor adsorption and platelet adhesion under both static and flow conditionsJournal of Biomedical Materials Research Part A, 2008
- Transfusion and hemostasis in cardiac surgeryTransfusion, 2008
- RETRACTED: Evaluation of a New Platelet Function Analyzer in Cardiac Surgery: A Comparison of Modified Thromboelastography and Whole-Blood AggregometryJournal of Cardiothoracic and Vascular Anesthesia, 2008
- Changes in coagulation and fibrinolytic parameters caused by extracorporeal circulationHeart and Vessels, 1996
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959