Cyclodextrin‐based nonaqueous electrokinetic chromatography with UV and mass spectrometric detection: Application to the impurity profiling of amiodarone
- 1 August 2008
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3575-3581
Abstract
The potential of nonaqueous electrokinetic chromatography (NAEKC) using cyclodextrins (CD) for the analysis of basic drugs and related compounds was evaluated. Both UV absorbance and mass spectrometric (MS) detection were employed. Addition of neutral CD to the NA background electrolyte did not significantly enhance the separation of a test mixture of basic drugs, and no change in selectivity was observed. In contrast, anionic single-isomer-sulfated CD strongly added to the selectivity of the NAEKC system inducing an improved resolution among the test compounds and increasing the migration time window. The applicability of the NAEKC system using anionic CD is demonstrated by the profiling of a sample of the drug amiodarone that had been stored for 1 year at room temperature. Amiodarone is poorly soluble in water. NAEKC-UV analysis indicated the presence of at least seven impurities in the amiodarone sample. In order to identify these compounds, the NAEKC system was coupled directly to electrospray ionization (ESI) ion-trap MS. The total of detected impurities increased to 12 due to the added sensitivity and selectivity of MS detection. Based on the acquired MS/MS data, three sample constituents could be identified as ‘known’ impurities (British Pharmacopoeia), whereas for three unknown impurities molecular structures could be proposed. Estimated limits of detection for amiodarone using the NAEKC method were 1 μg/mL with UV detection and 15 ng/mL with ESI-MS detection (full-scan). Based on relative responses, the impurity content of the stored drug substance was estimated to be 0.33 and 0.47% using NAEKC-UV and NAEKC-ESI-MS, respectively.Keywords
This publication has 21 references indexed in Scilit:
- Coupling of non‐aqueous electrokinetic chromatography using cationic cyclodextrins with electrospray ionization mass spectrometryRapid Communications in Mass Spectrometry, 2008
- A liquid chromatography–mass spectrometry assay method for simultaneous determination of amiodarone and desethylamiodarone in rat specimensBiomedical Chromatography, 2007
- Enantiomeric separation of acidic compounds using single‐isomer amino cyclodextrin derivatives in nonaqueous capillary electrophoresisElectrophoresis, 2006
- Determination of amiodarone and desethylamiodarone in horse plasma and urine by high-performance liquid chromatography combined with UV detection and electrospray ionization mass spectrometryJournal of Chromatography B, 2006
- On-line coupling of cyclodextrin mediated nonaqueous capillary electrophoresis to mass spectrometry for the determination of salbutamol enantiomers in urineJournal of Pharmaceutical and Biomedical Analysis, 2005
- Validation of a Stability Indicating LC Method for Amiodarone HCL and Related SubstancesChromatographia, 2005
- Enantiomeric separation of basic compounds using heptakis(2,3‐di‐O‐methyl‐6‐O‐sulfo)‐β‐cyclodextrin in combination with potassium camphorsulfonate in nonaqueous capillary electrophoresis: Optimization by means of an experimental designElectrophoresis, 2004
- Effects of background electrolyte composition and addition of selectors on separation selectivity in nonaqueous capillary electrophoresisElectrophoresis, 2003
- Nonaqueous capillary electrophoresis: A versatile completion of electrophoretic separation techniquesElectrophoresis, 2000
- About some aspects of the use of charged cyclodextrins for capillary electrophoresis enantioseparationElectrophoresis, 1994