Govert W. Somsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Govert W. Somsen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Gerhardus J. de Jong
Biomolecular Analysis Utrecht University the Netherlands
4 shared publicationsBregje J. de Kort
Biomolecular Analysis, Utrecht University, the Netherlands
2 shared publicationsRoelof Mol
Department of Biomedical Analysis, Utrecht University, Sorbonnelaan 16, 3584 CA, Utrecht, The Netherlands
2 shared publicationsDragana Č. Radenović
Department of Biomedical Analysis, Utrecht University, TB Utrecht, The Netherlands
1 shared publication- Javier Sastre Toraño
Department of Chemical Biology and Drug Discovery, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, the Netherlands
1 shared publication Peter M.J.M. Jongen
1 shared publication
Latest Publications
- 28 August 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (19-20) , 2996-3001
Profiling of erythropoietin products by capillary electrophoresis with native fluorescence detection
The potential of CE with native fluorescence detection (Flu) for the profiling of the therapeutic protein erythropoietin (EPO) was studied. EPO is a highly heterogeneous glycoprotein comprising a large number of isoforms. CE was applied to induce separation among the various glycoforms. Native Flu of EPO provided high detection selectivity yielding good signal‐to‐noise ratios and stable baselines, particularly when compared to conventional UV absorbance detection. In order to enhance EPO isoform resolution, CE was performed using a capillary with a neutral coating in combination with a simple BGE of 2.0 M acetic acid (pH 2.1). CE‐Flu analysis of the EPO biological reference preparation of the European Pharmacopeia resulted in a highly detailed glycoform profile. Migration time RSDs for selected EPO isoforms were less than 0.22% and 0.80% for intraday and interday repeatability, respectively. RSDs for relative peak intensity of the major EPO isoforms were less than 3%. The achieved resolution, migration time stability, and sensitivity allowed discrimination of different EPO products (EPO‐α and EPO‐β) based on the recorded glycoform pattern. The developed CE‐Flu method is relatively straightforward, and shows potential for quality control in biopharmaceutical production.
- 28 August 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (19-20) , 2996-3001
Profiling of erythropoietin products by capillary electrophoresis with native fluorescence detection
The potential of CE with native fluorescence detection (Flu) for the profiling of the therapeutic protein erythropoietin (EPO) was studied. EPO is a highly heterogeneous glycoprotein comprising a large number of isoforms. CE was applied to induce separation among the various glycoforms. Native Flu of EPO provided high detection selectivity yielding good signal‐to‐noise ratios and stable baselines, particularly when compared to conventional UV absorbance detection. In order to enhance EPO isoform resolution, CE was performed using a capillary with a neutral coating in combination with a simple BGE of 2.0 M acetic acid (pH 2.1). CE‐Flu analysis of the EPO biological reference preparation of the European Pharmacopeia resulted in a highly detailed glycoform profile. Migration time RSDs for selected EPO isoforms were less than 0.22% and 0.80% for intraday and interday repeatability, respectively. RSDs for relative peak intensity of the major EPO isoforms were less than 3%. The achieved resolution, migration time stability, and sensitivity allowed discrimination of different EPO products (EPO‐α and EPO‐β) based on the recorded glycoform pattern. The developed CE‐Flu method is relatively straightforward, and shows potential for quality control in biopharmaceutical production.
- 1 June 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (25) , 3978-3991
On-line coupling of electrokinetic chromatography and mass spectrometry
- 1 June 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (25) , 3978-3991
On-line coupling of electrokinetic chromatography and mass spectrometry
- 22 May 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (21) , 4629-4632
Lamp-based native fluorescence detection of proteins in capillary electrophoresis
- 22 May 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (21) , 4629-4632
Lamp-based native fluorescence detection of proteins in capillary electrophoresis
- 1 May 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (18) , 4107-4112
Determination of oversulfated chondroitin sulfate and dermatan sulfate impurities in heparin by capillary electrophoresis
- 1 May 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (18) , 4107-4112
Determination of oversulfated chondroitin sulfate and dermatan sulfate impurities in heparin by capillary electrophoresis
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3575-3581
Cyclodextrin‐based nonaqueous electrokinetic chromatography with UV and mass spectrometric detection: Application to the impurity profiling of amiodarone
The potential of nonaqueous electrokinetic chromatography (NAEKC) using cyclodextrins (CD) for the analysis of basic drugs and related compounds was evaluated. Both UV absorbance and mass spectrometric (MS) detection were employed. Addition of neutral CD to the NA background electrolyte did not significantly enhance the separation of a test mixture of basic drugs, and no change in selectivity was observed. In contrast, anionic single-isomer-sulfated CD strongly added to the selectivity of the NAEKC system inducing an improved resolution among the test compounds and increasing the migration time window. The applicability of the NAEKC system using anionic CD is demonstrated by the profiling of a sample of the drug amiodarone that had been stored for 1 year at room temperature. Amiodarone is poorly soluble in water. NAEKC-UV analysis indicated the presence of at least seven impurities in the amiodarone sample. In order to identify these compounds, the NAEKC system was coupled directly to electrospray ionization (ESI) ion-trap MS. The total of detected impurities increased to 12 due to the added sensitivity and selectivity of MS detection. Based on the acquired MS/MS data, three sample constituents could be identified as ‘known’ impurities (British Pharmacopoeia), whereas for three unknown impurities molecular structures could be proposed. Estimated limits of detection for amiodarone using the NAEKC method were 1 μg/mL with UV detection and 15 ng/mL with ESI-MS detection (full-scan). Based on relative responses, the impurity content of the stored drug substance was estimated to be 0.33 and 0.47% using NAEKC-UV and NAEKC-ESI-MS, respectively.
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3575-3581
Cyclodextrin‐based nonaqueous electrokinetic chromatography with UV and mass spectrometric detection: Application to the impurity profiling of amiodarone
The potential of nonaqueous electrokinetic chromatography (NAEKC) using cyclodextrins (CD) for the analysis of basic drugs and related compounds was evaluated. Both UV absorbance and mass spectrometric (MS) detection were employed. Addition of neutral CD to the NA background electrolyte did not significantly enhance the separation of a test mixture of basic drugs, and no change in selectivity was observed. In contrast, anionic single-isomer-sulfated CD strongly added to the selectivity of the NAEKC system inducing an improved resolution among the test compounds and increasing the migration time window. The applicability of the NAEKC system using anionic CD is demonstrated by the profiling of a sample of the drug amiodarone that had been stored for 1 year at room temperature. Amiodarone is poorly soluble in water. NAEKC-UV analysis indicated the presence of at least seven impurities in the amiodarone sample. In order to identify these compounds, the NAEKC system was coupled directly to electrospray ionization (ESI) ion-trap MS. The total of detected impurities increased to 12 due to the added sensitivity and selectivity of MS detection. Based on the acquired MS/MS data, three sample constituents could be identified as ‘known’ impurities (British Pharmacopoeia), whereas for three unknown impurities molecular structures could be proposed. Estimated limits of detection for amiodarone using the NAEKC method were 1 μg/mL with UV detection and 15 ng/mL with ESI-MS detection (full-scan). Based on relative responses, the impurity content of the stored drug substance was estimated to be 0.33 and 0.47% using NAEKC-UV and NAEKC-ESI-MS, respectively.