Using computed tomography to recover hidden medieval fragments beneath early modern leather bindings, first results
Open Access
- 24 April 2023
- journal article
- research article
- Published by Springer Nature in Heritage Science
- Vol. 11 (1) , 1-11
Abstract
Medieval bindings fragments have become increasingly interesting to Humanities researchers as sources for the textual and material history of medieval Europeans. Later book binders used these discarded and repurposed pieces of earlier medieval manuscripts to reinforce the structures of other manuscripts and printed books. That many of these fragments are contained within and obscured by decorative bindings that cannot be dismantled ethically has limited their discovery and description. Although previous attempts to recover these texts using IRT and MA-XRF scanning have been successful, the extensive time required to scan a single book, and the need to modify or create specialized IRT or MA-XRF equipment for this method are drawbacks. Our research proposes and tests the capabilities of medical CT scanning technologies (commonly available at research university medical schools) for making visible and legible these fragments hidden under leather bindings. Our research team identified three sixteenth-century printed codices in our university libraries that were evidently bound in tawed leather by one workshop. The damaged cover of one of these three had revealed medieval manuscript fragments on the book spine; this codex served as a control for testing the other two volumes to see if they, too, contain fragments. The use of a medical CT scanner proved successful in visualizing interior book-spine structures and some letterforms, but not all of the text was made visible. The partial success of CT-scanning points to the value of further experimentation, given the relatively wide availability of medical imaging technologies, with their potential for short, non-destructive, 3D imaging times.Keywords
Funding Information
- Office of the Vice President for Research and Economic Development, University of Iowa
- National Institutes of Health (R01-EB004640, S10-OD018526, S10-OD018526, R01-EB004640)
This publication has 30 references indexed in Scilit:
- The Importance of Spectral SeparationInvestigative Radiology, 2015
- Very Low-Dose (0.15 mGy) Chest CT Protocols Using the COPDGene 2 Test Object and a Third-Generation Dual-Source CT Scanner With Corresponding Third-Generation Iterative Reconstruction SoftwareInvestigative Radiology, 2015
- Infrared Thermography Applied to the Study of Cultural HeritageInternational Journal of Thermophysics, 2014
- Hidden Text Detection by Infrared Thermography / Anwendung der aktiven Infrarotthermographie (IRT) zur Erfassung von verdeckten Texten / Utilisation de la thermographie infrarouge (IRT) pour détecter des textes cachésRestaurator. International Journal for the Preservation of Library and Archival Material, 2013
- A Carolingian Manuscript Fragment from the Ninth Century in Amsterdam University Library, used as the Binding for ‘Band 1 E 22’Quærendo, 2013
- Active infrared thermography applied to the investigation of art and historic artefactsJournal of Thermal Analysis and Calorimetry, 2011
- Material differentiation by dual energy CT: initial experienceEuropean Radiology, 2006
- Segmentation of the Surfaces of the Retinal Layer from OCT Images2006
- Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic ApproachIEEE Transactions on Pattern Analysis and Machine Intelligence, 2005
- Membra DisiectaThe British Museum Quarterly, 1938