Honghai Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Honghai Zhang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Milan Sonka
Iowa Initiative for Artificial Intelligence, University of Iowa, Iowa City, IA 52242, USA
4 shared publications - Andreas Wahle
Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa
3 shared publications - Ademola K. Abiose
Department of Internal Medicine, The University of Iowa, Iowa City, IA 52242, USA
1 shared publication - Caitlin Ward
Division of Biostatistics and Health Data Science University of Minnesota Minneapolis Minnesota USA
1 shared publication - Dipti Gupta
Department of Internal Medicine, The University of Iowa, Iowa City, IA 52242, USA
1 shared publication - Dwayne N. Campbell
Department of Internal Medicine, The University of Iowa, Iowa City, IA 52242, USA
1 shared publication
Latest Publications
- Open Access
- 24 April 2023
- Published by Springer Nature in Heritage Science
- Vol. 11 (1) , 1-11
Using computed tomography to recover hidden medieval fragments beneath early modern leather bindings, first results
Medieval bindings fragments have become increasingly interesting to Humanities researchers as sources for the textual and material history of medieval Europeans. Later book binders used these discarded and repurposed pieces of earlier medieval manuscripts to reinforce the structures of other manuscripts and printed books. That many of these fragments are contained within and obscured by decorative bindings that cannot be dismantled ethically has limited their discovery and description. Although previous attempts to recover these texts using IRT and MA-XRF scanning have been successful, the extensive time required to scan a single book, and the need to modify or create specialized IRT or MA-XRF equipment for this method are drawbacks. Our research proposes and tests the capabilities of medical CT scanning technologies (commonly available at research university medical schools) for making visible and legible these fragments hidden under leather bindings. Our research team identified three sixteenth-century printed codices in our university libraries that were evidently bound in tawed leather by one workshop. The damaged cover of one of these three had revealed medieval manuscript fragments on the book spine; this codex served as a control for testing the other two volumes to see if they, too, contain fragments. The use of a medical CT scanner proved successful in visualizing interior book-spine structures and some letterforms, but not all of the text was made visible. The partial success of CT-scanning points to the value of further experimentation, given the relatively wide availability of medical imaging technologies, with their potential for short, non-destructive, 3D imaging times.
- 24 April 2023
- Published by Springer Nature in Heritage Science
- Vol. 11 (1) , 1-11
Open AccessUsing computed tomography to recover hidden medieval fragments beneath early modern leather bindings, first results
Medieval bindings fragments have become increasingly interesting to Humanities researchers as sources for the textual and material history of medieval Europeans. Later book binders used these discarded and repurposed pieces of earlier medieval manuscripts to reinforce the structures of other manuscripts and printed books. That many of these fragments are contained within and obscured by decorative bindings that cannot be dismantled ethically has limited their discovery and description. Although previous attempts to recover these texts using IRT and MA-XRF scanning have been successful, the extensive time required to scan a single book, and the need to modify or create specialized IRT or MA-XRF equipment for this method are drawbacks. Our research proposes and tests the capabilities of medical CT scanning technologies (commonly available at research university medical schools) for making visible and legible these fragments hidden under leather bindings. Our research team identified three sixteenth-century printed codices in our university libraries that were evidently bound in tawed leather by one workshop. The damaged cover of one of these three had revealed medieval manuscript fragments on the book spine; this codex served as a control for testing the other two volumes to see if they, too, contain fragments. The use of a medical CT scanner proved successful in visualizing interior book-spine structures and some letterforms, but not all of the text was made visible. The partial success of CT-scanning points to the value of further experimentation, given the relatively wide availability of medical imaging technologies, with their potential for short, non-destructive, 3D imaging times.
- Open Access
Radiomic Based Machine Learning Performance for a Three Class Problem in Neuro-Oncology: Time to Test the Waters?
Prior radiomics studies have focused on two-class brain tumor classification, which limits generalizability. The performance of radiomics in differentiating the three most common malignant brain tumors (glioblastoma (GBM), primary central nervous system lymphoma (PCNSL), and metastatic disease) is assessed; factors affecting the model performance and usefulness of a single sequence versus multiparametric MRI (MP-MRI) remain largely unaddressed. This retrospective study included 253 patients (120 metastatic (lung and brain), 40 PCNSL, and 93 GBM). Radiomic features were extracted for whole a tumor mask (enhancing plus necrotic) and an edema mask (first pipeline), as well as for separate enhancing and necrotic and edema masks (second pipeline). Model performance was evaluated using MP-MRI, individual sequences, and the T1 contrast enhanced (T1-CE) sequence without the edema mask across 45 model/feature selection combinations. The second pipeline showed significantly high performance across all combinations (Brier score: 0.311–0.325). GBRM fit using the full feature set from the T1-CE sequence was the best model. The majority of the top models were built using a full feature set and inbuilt feature selection. No significant difference was seen between the top-performing models for MP-MRI (AUC 0.910) and T1-CE sequence with (AUC 0.908) and without edema masks (AUC 0.894). T1-CE is the single best sequence with comparable performance to that of multiparametric MRI (MP-MRI). Model performance varies based on tumor subregion and the combination of model/feature selection methods.
Open AccessRadiomic Based Machine Learning Performance for a Three Class Problem in Neuro-Oncology: Time to Test the Waters?
Prior radiomics studies have focused on two-class brain tumor classification, which limits generalizability. The performance of radiomics in differentiating the three most common malignant brain tumors (glioblastoma (GBM), primary central nervous system lymphoma (PCNSL), and metastatic disease) is assessed; factors affecting the model performance and usefulness of a single sequence versus multiparametric MRI (MP-MRI) remain largely unaddressed. This retrospective study included 253 patients (120 metastatic (lung and brain), 40 PCNSL, and 93 GBM). Radiomic features were extracted for whole a tumor mask (enhancing plus necrotic) and an edema mask (first pipeline), as well as for separate enhancing and necrotic and edema masks (second pipeline). Model performance was evaluated using MP-MRI, individual sequences, and the T1 contrast enhanced (T1-CE) sequence without the edema mask across 45 model/feature selection combinations. The second pipeline showed significantly high performance across all combinations (Brier score: 0.311–0.325). GBRM fit using the full feature set from the T1-CE sequence was the best model. The majority of the top models were built using a full feature set and inbuilt feature selection. No significant difference was seen between the top-performing models for MP-MRI (AUC 0.910) and T1-CE sequence with (AUC 0.908) and without edema masks (AUC 0.894). T1-CE is the single best sequence with comparable performance to that of multiparametric MRI (MP-MRI). Model performance varies based on tumor subregion and the combination of model/feature selection methods.
- 1 January 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (1) , 72-88
Novel Indices for Left-Ventricular Dyssynchrony Characterization Based on Highly Automated Segmentation From Real-Time 3-D Echocardiography
- 1 January 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (1) , 72-88
Novel Indices for Left-Ventricular Dyssynchrony Characterization Based on Highly Automated Segmentation From Real-Time 3-D Echocardiography
- 3 November 2010
- Published by Springer Nature
- p. 35-102
Three-dimensional and Four-dimensional Cardiopulmonary Image Analysis
- 3 November 2010
- Published by Springer Nature
- p. 35-102
Three-dimensional and Four-dimensional Cardiopulmonary Image Analysis
- 25 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (2) , 350-364
4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function
In this study, a combination of active shape model (ASM) and active appearance model (AAM) was used to segment the left and right ventricles of normal and Tetralogy of Fallot (TOF) hearts on 4-D (3-D+time) MR images. For each ventricle, a 4-D model was first used to achieve robust preliminary segmentation on all cardiac phases simultaneously and a 3-D model was then applied to each phase to improve local accuracy while maintaining the overall robustness of the 4-D segmentation. On 25 normal and 25 TOF hearts, in comparison to the expert traced independent standard, our comprehensive performance assessment showed subvoxel segmentation accuracy, high overlap ratios, good ventricular volume correlations, and small percent volume differences. Following 4-D segmentation, novel quantitative shape and motion features were extracted using shape information, volume-time and dV/dt curves, analyzed and used for disease status classification. Automated discrimination between normal/TOF subjects achieved 90%-100% sensitivity and specificity. The features obtained from TOF hearts show higher variability compared to normal subjects, suggesting their potential use as disease progression indicators. The abnormal shape and motion variations of the TOF hearts were accurately captured by both the segmentation and feature characterization.
- 25 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (2) , 350-364
4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function
In this study, a combination of active shape model (ASM) and active appearance model (AAM) was used to segment the left and right ventricles of normal and Tetralogy of Fallot (TOF) hearts on 4-D (3-D+time) MR images. For each ventricle, a 4-D model was first used to achieve robust preliminary segmentation on all cardiac phases simultaneously and a 3-D model was then applied to each phase to improve local accuracy while maintaining the overall robustness of the 4-D segmentation. On 25 normal and 25 TOF hearts, in comparison to the expert traced independent standard, our comprehensive performance assessment showed subvoxel segmentation accuracy, high overlap ratios, good ventricular volume correlations, and small percent volume differences. Following 4-D segmentation, novel quantitative shape and motion features were extracted using shape information, volume-time and dV/dt curves, analyzed and used for disease status classification. Automated discrimination between normal/TOF subjects achieved 90%-100% sensitivity and specificity. The features obtained from TOF hearts show higher variability compared to normal subjects, suggesting their potential use as disease progression indicators. The abnormal shape and motion variations of the TOF hearts were accurately captured by both the segmentation and feature characterization.