Surface coating to improve the metal-cement bonding in cemented femur stems
Authors:
- 2 October 2007
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (8) , 773-781
Abstract
Introduction Hydrolytic debonding of the metal-cement interface is one of the main reasons for aseptic loosening in cemented hip arthroplasty. Materials and methods BiContact femur stems (CoCrMo-/TiAl6V4-alloy) were coated by a silica/silane interlayer coating system. The stems were cemented into artificial femurs. The cyclical loading (DIN ISO 7206-4) was performed within a hip-simulator. Uncoated stems (CoCrMo-/TiAl6V4-alloy) were prepared and loaded the same way. After loading, the metal-cement and the bone-cement interfaces were analysed. Unloaded uncoated and unloaded coated BiContact stems served as a control. Results The coated loaded stems showed a significant reduction in debonding and cement failure (P ≤ 0.05). A high correlation was documented between debonding and cement failure (r Spear ≥ 0.9). There was no significant difference between CoCrMo- and TiAl6V4-stems (P ≥ 0.05). Conclusion The silica/silane coating significantly decreased hydrolytic debonding at the metal-bone cement interface with consecutively less cement failure.Keywords
This publication has 21 references indexed in Scilit:
- Ist die Implantation von Titan-Schäften in der Hüftendoprothetik wirklich obsolet?Zeitschrift für Orthopädie und ihre Grenzgebiete, 2005
- THE SWEDISH TOTAL HIP REPLACEMENT REGISTERJournal of Bone and Joint Surgery, 2002
- Einfluss der Femurmarkraumspülung auf die periprothetische Zementverteilung: Jet-Lavage versus SpritzenspülungZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- Evaluation of Cement Stresses in Finite Element Analyses of Cemented Orthopaedic ImplantsJournal of Biomechanical Engineering, 2001
- The effect of a silane coupling agent on the bond strength of bone cement and cobalt-chrome alloyJournal of Biomedical Materials Research, 1999
- Cement Debonding Process of Total Hip Arthroplasty StemsClinical Orthopaedics and Related Research, 1997
- Ursachen, Diagnostik und Therapie der aseptischen Hüftendoprothesenlockerung - eine StandortbestimmungZeitschrift für Orthopädie und ihre Grenzgebiete, 1997
- The mechanism of loosening in cemented hip prostheses determined from long-term resultsArchives of orthopaedic and trauma surgery, 1997
- The durability of some epoxide adhesive-bonded joints on exposure to moist warm airInternational Journal of Adhesion and Adhesives, 1980
- ARTHROPLASTY OF THE HIP A New OperationThe Lancet, 1961