TMTorsten Mumme

Torsten Mumme

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Torsten Mumme has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Endoglin (CD105) expression differentiates between aseptic loosening and periprosthetic joint infection after total joint arthroplasty

    by Philipp Jansen, Torsten Mumme, Thomas Randau, Sascha Gravius, Benita Hermanns-Sachweh

    The differentiation between aseptic loosening and periprosthetic joint infection (PJI) after total joint arthroplasty is essential for successful therapy. A better understanding of pathogenesis of aseptic loosening and PJI may help to prevent or treat these complications. Previous investigations revealed an increased vascularization in the periprosthetic membrane in cases of PJI via PET signals. Based on these findings our hypothesis was that PJI is associated with an increased neovascularization in the periprosthetic membrane. Tissue samples from periprosthetic membranes of the bone-implant interface were investigated histologically for inflammation, wear particles, vascularization and fibrosis. To identify vascular structures antibodies against CD 31, CD 34, factor VIII and CD 105 (endoglin) were applied for immunohistochemical investigations. According to a consensus classification of Morawietz the tissue samples were divided into four types: type I (wear particle induced type, n = 11), type II (infectious type, n = 7), type III (combined type, n = 7) and type IV (indeterminate type, n = 7). Patients with PJI (type II) showed a pronounced infiltration of neutrophil granulocytes in the periprosthetic membrane and an enhanced neovascularization indicated by positive immunoreaction with antibodies against CD 105 (endoglin). Tissue samples classified as type I, type III and type IV showed significantly less immune reaction for CD 105. In cases of aseptic loosening and PJI vascularization is found in different expression in periprosthetic membranes. However, in aseptic loosening, there is nearly no neovascularization with CD 105-positive immune reaction. Therefore, endoglin (CD 105) expression allows for differentiation between aseptic loosening and PJI.


  • Silikatbeschichtung zementierter Titanschäfte für die Reduzierung aseptischer Lockerungsraten

    by R. Marx, R. Faramarzi, F. Jungwirth, B. V. Kleffner, T. Mumme, M. Weber, D. C. Wirtz

    Studienziel: CoCrMo-Legierungen sind kontraindiziert bei Allergikern. Für diese Patienten ist eine zementierte Prothese aus Titan(-Legierung) indiziert. Zementierte Schäfte aus Titan(-Legierung) können allerdings in Abhängigkeit von Prothesengeometrie und Oberflächentextur aseptische Lockerungsraten zeigen, die klinisch nicht tolerierbar sind. Große Rauigkeit in Verbindung mit geringer Abriebfestigkeit bedingt eine hohe Konzentration an Titanabriebpartikeln und diese die aseptische Lockerung. Andererseits unterstützt eine große Rauigkeit die mechanische Retention des Knochenzements auf der Prothesenoberfläche. Dadurch verbessert sich initial das Migrationsverhalten; reduzierte Mikrobewegungen zwischen Schaft und Prothesenlager sind die Folge. Zwischen Knochenzement und metallischer Oberfläche besteht aber trotzdem kein hydrolytisch stabiler Verbund, sodass mittelfristig zwangsläufig ein Debonding vorhersehbar ist. Sachgerechter sind bei leicht abradierbaren Prothesen wie Hüft-Endoprothesenschäften aus Titan(-Legierung) kleine Rauigkeiten. Das ungünstige Migrationsverhalten und die größeren Mikrobewegungen können durch eine Silikatbeschichtung (Elektrolytischer [ECD-] oder PVD-Auftrag) kompensiert werden. Methode: Um die Wirksamkeit dieser Beschichtung zu untersuchen, wurden Zugprüfkörper (n = 5) und Ausstoßkegel (n = 3…5) so raugestrahlt, dass Rauigkeiten zwischen Ra = 0,8 mm (Rz = 4 mm) und Ra = 2,0 mm (Rz = 9 mm) entstehen. Nach Silikatbeschichtung wurden diese Prüfkörper zementiert und nach vorgegebenen Fristen und Zyklenzahlen hydrolytischer und wechselnder mechanischer Belastung auf ihre Verbund- und Ausstoßfestigkeit geprüft. Ergebnisse: Die beobachtete Verbundfestigkeit im Zugtest war bei Ra = 1,7 mm für alle untersuchten Auslagerungsintervalle stets größer als 25 MPa. Die Beschichtung führt deshalb auch bei moderatem Raustrahlen (Ra = 1,7 mm) zu einer Retention, die klinisch ausreichend sein sollte, um Migration und Mikrobewegung weitgehend zu unterbinden. Schlussfolgerung: Der Abrieb im Interface, der zugleich Folge und Ursache der Lockerung ist, sollte sich reduzieren oder vermeiden lassen, wenn die Haftung des Zements auf dem metallischen Schaft durch ein chemisches Verbundsystem insbesondere gegen hydrolytisches Debonding dauerhaft stabilisiert wird. Aim: For cemented hip prostheses, all requirements can be fulfilled by using forged Co/Cr/Mo stems. Co/Cr/Mo alloys, however, are contraindicated for allergy sufferers. For these patients, a cemented prosthesis made of titanium (alloy) would be indicated. Cemented stems from titanium (alloy), depending on the geometry of the prosthesis and its specific surface texture, however, may have loosening rates which are clinically not tolerable. In comparison to Co/Cr/Mo alloys, the greater roughness in conjunction with lesser abrasion resistance of titanium-based alloys leads to high loosening rates caused by abrasion. On the other hand, the greater surface roughness permits good mechanical retention of bone cement to the surface. Good mechanical retention enhances migration behaviour and reduces micromotions. However, there is no stable hydrolytic bond between bone cement and metallic surface; intermediate-term debonding between metal and bone cement is predictable. This debonding results in relative movements, consequently in wear particles which have their origin both from the rough metallic surface and from the PMMA cement. The roughness of the metallic surface operates as emery and with that, a rubbing wear from the PMMA. Method: For the above reasons, a low or moderate roughness is essential for easily abradable implants such as shafts made of titanium (alloy) because low roughness provides a fail-safe running function in case of debonding. Thus, one must allow for inappropriate migration behaviour accompanied by greater micromotions due to insufficient mechanical retention in the case of low roughness. This can be accomplished by a silicate layer coating applied to the metal shaft surface via electrochemical “ECD” or physical vapour deposition “PVD”. For analysis, specimens (screws for pull-out, cones for push-out tests) were sand-blasted, so that roughnesses between Ra = 0.8 µm (Rz = 4 µm) and Ra = 2.0 µm (Rz = 9 µm) were generated. Results: The bond strengths observed in tensile tests for roughnesses of Ra = 1.7 mm were always well above 25 MPa for all periods of hydrolytic load. Therefore, the investigation shows that surfaces of moderate roughness (Ra = 1.7 µm), however coated, provide a steady retention. Cave-in and micromotions should widely be prevented. Conclusion: The abrasion, which is a consequence of and reason for debonding and loosening at the same time, should be avoidable if the bonding of cement on the metallic shaft is stabilised with the help of a suitable chemical bond system.


  • Funktionalität und Genauigkeit eines fluoroskopischen Navigationssystems zur Implantation von Hüftkopf-Oberflächenersatzprothesen: Eine Anatomiestudie

    by S. Gravius, P. Belei, M. de la Fuente, R. Müller-Rath, K. Radermacher, D. Wirtz, T. Mumme

    Einleitung: Der moderne Oberflächenersatz des Hüftgelenkes bietet eine Alternative in der Behandlung der Coxarthrose für den jungen und aktiven Patienten. Dennoch gelten vorwiegend operationstechnische Gründe, insbesondere die Schädigung der Femurhalskortikalis („Notching des Schenkelhalses“) wie auch eine ungenaue Prothesenpositionierung während des Eingriffes, als ursächlich für ein mögliches Versagen der femoralen Komponente. Material und Methoden: Im Rahmen einer Anatomieuntersuchung an 3 fixierten Ganzkörperpräparaten wurden insgesamt 6 DUROM™-Hip-Oberflächenersatzprothesen navigiert eingesetzt. Ziel der Untersuchungen war die Evaluation der Funktionalität und der Genauigkeit eines neuartigen computergestützten fluoroskopie-basierten Planungs- und Navigationssystems auf Grundlage von Planungs- und Navigationsmodulen der Surgitaix AG, Aachen. Ergebnisse: Der durchschnittliche Winkelunterschied zwischen geplantem (135,2 ± 3,6°) und erreichtem Prothesenwinkel (136,2 ± 2,8°) betrug 1,9 ± 1,1°, die Abweichung zwischen geplantem (2,2 ± 1,3 mm) und erreichtem anterioren Offset (2,7 ± 2,3 mm) 1,2 ± 1,9 mm. Der durchschnittliche Abstand zwischen geplanter und erreichter Prothesenposition konnte mit 2,7 ± 1,3 mm gemessen werden. In keinem der 6 Fälle trat ein „Notching des Schenkelhalses“ auf. Der Zeitaufwand für die insgesamt 5 Planungs- und Navigationsschritte betrug im Durchschnitt 20,2 ± 2,5 min. Vor dem Hintergrund eines knochensparenden Vorgehens pfannenseitig entsprach in allen Fällen die geplante der letztendlich kleinstmöglich zu implantierenden femoralen Komponente. Schlussfolgerung: Das computergestützte fluoroskopische Planungs- und Navigationssystem zeigte im Rahmen der hier vorgestellten Anatomiestudie vielversprechende erste Ergebnisse. So erlaubt es eine praktikable intraoperative Planung und eine hohe Präzision bei der operativen Umsetzung dieser Planung. Dennoch muss sich das System - ähnlich der hier vorgestellten Anatomiestudie - in weiteren Studien wie im klinischen Alltag noch nachweisbar bewähren und in den klinischen Workflow integriert werden. Weiterführende Untersuchungen sollen unter zusätzlicher Integration eines Pfannenmoduls eine navigiert assistierte Bestimmung des „Range of Motion“ zur Verbesserung des postoperativen Bewegungsausmaßes beinhalten. Introduction: Resurfacing arthroplasty represents an alternative method to total hip replacement especially for the young and active patient. The main reasons for early implant failure are mal-positioning of the femoral component and notching of the femoral neck during femoral head preparation. Material and Methods: In the context of a cadaver study of formalin-fixed cadaveric full body specimens 6 DUROM™-Hip-Resurfacing prosthesis have been implanted under navigation control. The aim of the study was an evaluation of the functionality and accuracy of the computer-assisted planning and navigation system on the basis of a navigation module library from Surgitaix AG Aachen, Germany. Results: The main angulation error between planning (135.2 ± 3.6°) and navigation (136.2 ± 2.8°) was 1.9 ± 1.1°, the main anterior offset error between planning (2.2 ± 1.3 mm) and navigation (2.7 ± 2.3 mm) was 1.2 ± 1.9 mm. The main distance error between planning and navigation was 2.7 ± 1.3 mm. The mean time for all five planning and navigation steps was 20.2 ± 2.5 min. Against the background of a acetabular bone-saving approach in all 6 cases the smallest possible femoral component could be implanted. Conclusion: The computer-assisted fluoroscopic planning and navigation system for hip resurfacing showed within the scope of this cadaver study first promising results. The system approaches a practicable intraoperative planning with a high accuracy in operative implementation. Nevertheless, the potential benefit has to be evaluated in further clinical studies, especially from the perspective of a possible integration of this navigation system into the clinical work-flow. Further studies should consider a fluoroscopic-assisted range of motion assessment under consideration of an additional cup-module to enhance the postoperative range of motion after hip resurfacing procedures.


  • Surface pretreatment of endoprostheses by silica/silane to optimise the hydrolytic stability between bone cement and metal

    by T. Mumme, R. Marx, R. Müller-Rath, S. Gravius, S. Andereya, D.C. Wirtz

    Die aseptische Lockerung von zementierten Hüft- und Knieendoprothesen ist ein aktuell ungelöstes Problem. Diesbezüglich ist unter anderem eine hydrolysestabile Verbundfestigkeit der Grenzschicht Metall/PMMA (Polymethylmethacrylat) von entscheidender prognostischer Bedeutung. Mittels Silikatisierung/Silanisierung beschichtete Femurschaft- und Tibiaplateauendoprothesen wurden in „Kunstknochen“ zementiert implantiert und nach DIN-ISO-Norm belastet. Nach dynamischer Belastung erfolgte die auflicht- und fluoreszenzmikroskopische Grenzschicht- und Zementmantelanalyse. Unbeschichtete Endoprothesen dienten als Kontrollgruppen. Die silikatisierten/silanisierten femoralen und tibialen Endoprothesen zeigten verglichen mit den unbeschichteten eine statistisch hoch signifikante Reduktion hinsichtlich Spalt- und Rissbildung in der Grenzschicht Metall/PMMA sowie im Zementmantel selbst. Durch die silikatisierte/silanisierte Implantatoberflächenbeschichtung von zementierten Femurschaft- und Tibiaplateauendoprothesen kann ein hydrolytisches Debonding in der Grenzschicht Metall/PMMA mit konsekutiver Zementmantelzerrüttung vermieden werden. Dieses könnte eine längerfristige Stabilität des Metall-PMMA-Verbundes mit reduzierter mechanischer Lockerungsrate bewirken. The aseptic loosening of cemented total hip and knee arthroplasties is still an unsolved problem. In this regard, the hydrolytic resistance in the metal-to-bone cement interface is of major importance. Cemented pretreated femur stems and tibia components coated by means of a silica/silane interlayer system were dynamically loaded with the help of a hip and knee simulator similar to DIN ISO Norm. After loading, the components were microscopically analysed concerning both debonding in the metal-to-bone cement interface and cement mantle defects. These data were matched with uncoated components. Unloaded coated and uncoated femur and tibia components acted as controls. Compared with uncoated components, the pretreated and coated ones yielded a significant reduction in cement defects as well as of debonding in the metal-to-bone cement interface. Using the silica/silane interlayer system for cemented femur and tibia components, hydrolytic debonding in the metal-to-bone cement interface with following cement mantle failure can be reduced. This could help increase the long-term stability of the metal-to-bone cement compound, with decreased aseptic loosening.


  • Surface coating to improve the metal-cement bonding in cemented femur stems

    by T. Mumme, R. Marx, R. Müller-Rath, C. H. Siebert, D. C. Wirtz

    Introduction Hydrolytic debonding of the metal-cement interface is one of the main reasons for aseptic loosening in cemented hip arthroplasty. Materials and methods BiContact femur stems (CoCrMo-/TiAl6V4-alloy) were coated by a silica/silane interlayer coating system. The stems were cemented into artificial femurs. The cyclical loading (DIN ISO 7206-4) was performed within a hip-simulator. Uncoated stems (CoCrMo-/TiAl6V4-alloy) were prepared and loaded the same way. After loading, the metal-cement and the bone-cement interfaces were analysed. Unloaded uncoated and unloaded coated BiContact stems served as a control. Results The coated loaded stems showed a significant reduction in debonding and cement failure (P ≤ 0.05). A high correlation was documented between debonding and cement failure (r Spear ≥ 0.9). There was no significant difference between CoCrMo- and TiAl6V4-stems (P ≥ 0.05). Conclusion The silica/silane coating significantly decreased hydrolytic debonding at the metal-bone cement interface with consecutively less cement failure.


  • Einsatz eines amphiphilen Haftvermittlers im Schafsmodell zur Verbesserung der femoralen Knochenzement-Knochen-Verbundfestigkeit in der zementierten Hüftendoprothetik

    by R. Müller-Rath, D. Wirtz, S. Andereya, S. Gravius, B. Hermanns-Sachweh, R. Marx, T. Mumme

    Studienziel: Im Falle eines Hüftendoprothesenwechsels ist die zementierte Schaftreimplantation aufgrund einer fehlenden Mikro- und Makroverzahnung des Knochenzementes am glatten endostalen Knochen mit hohen Frühlockerungsraten verbunden. Um dieser reduzierten mechanischen Stabilität zementierter Revisionsschäfte entgegen zu wirken, kann durch einen amphiphilen Haftvermittler eine kovalente Verbindung zwischen hydrophobem Knochenzement und hydrophilem Knochen erzielt werden. Ziel dieser Studie ist es, den klinischen Nachweis der verbesserten mechanischen Stabilität zementierter Femurendoprothesen durch den Haftvermittler sowie dessen Biokompatibilität am Tiermodell Schaf zu erbringen. Methode: Es wurde insgesamt bei 20 Schafen eine zementierte Hüftendoprothese eingesetzt. In der Verumgruppe (n = 10) erfolgte die Implantation nach zusätzlicher Oberflächenkonditionierung des femoralen Implantatlagers mittels Knochenhaftvermittler. Die Standzeit aller Tiere betrug 9 Monate. Zur Beurteilung der Biokompatibilität wurde die Knochenneubildung im Bereich der Knochenzement-Knochen-Grenzfläche durch eine In-vivo-Fluoreszenzmarkierung von Osteoblasten dargestellt. Zusätzlich erfolgte die nativ-radiologische Beurteilung im Verlauf. Abschließend wurden die Femura definiert zersägt und das Knochenzement-Knochen-Interface histologisch untersucht. Ergebnisse: Die behandelten Prothesen der Verumgruppe zeigten einen festen Knochenzement-Knochen-Verbund, während in der unbehandelten Kontrollgruppe 7 von 10 Schäften mit adhärentem Knochenzement leicht aus dem ossären Implantatlager zu heben waren. Dieses entsprach den radiologischen sowie histologischen Ergebnissen mit deutlich vermehrter, progredienter Lysesaumbildung und bindegewebigem Interponat zwischen Knochenzement und Knochen in der Kontrolle verglichen mit der Verumgruppe. Der Haftvermittler war biokompatibel. Schlussfolgerung: Nach Anwendung des Knochenhaftvermittlers zeigten die zementierten Schäfte eine deutlich erhöhte Verbundstabilität ohne Hinweis auf Entzündungen oder Neoplasien bei erhaltender Implantatlagervitalität. In der klinischen Anwendung dieser Technik könnte eine Verlängerung der Standzeit von zementierten Revisionsschäften erreicht werden. Aim: Cemented revision of femoral components in total hip arthroplasty has shown high rates of early loosening due to reduced micro- and macroretention of the cement to the endostal bone stock. Enhanced stability can be reached by an amphiphilic bonder, which offers a covalent bonding of the hydrophobic cement to the hydrophilic bone. The aim of this study is to evaluate the biocompatibility of such a bonder and its effects on the mechanical stability of cemented hip arthroplasty stems in vivo. Methods: Total cemented hip arthroplasties were performed in 20 sheep. In the verum group (n = 10) the implant bed was preconditioned by application of the bonder prior to femoral stem implantation. To study the biocompatibility around the bone-cement interface fluorescent marking of osteoblasts was applied in vivo throughout the observation period of 9 months. Native X-rays of the hip joints were obtained immediately after implantation and after euthanasia. The bone-cement interface was examined histologically. Results: All stems of the verum group showed firm bonding of cement to bone in manual testing, while in 7 of the 10 controls the stems with adherent cement could be easily pulled out off the bony implant bed. This was coherent with significantly higher rates of progredient radiolucent lines and soft-tissue interpositions between bone and cement in the control group. The bonder was biocompatible. Conclusion: When preconditioned with an amphiphilic bonder, cemented stems showed a markedly higher adhesive strength to the cancellous bone without signs of inflammation or neoplasia. This procedure might offer enhanced longevity of cemented femoral revision stems in hip arthroplasty.


  • Improvement of the long-term adhesive strength between bone cement and bone in cemented cup arthroplasty: ex-vivo study

    by T. Mumme, S. Gravius, S. Andereya, R. Marx, D. C. Wirtz, R. Müller-Rath

    One of the main causes of cup loosening in cemented total hip replacement is the lack of a hydrolysis stable compound between the hydrophobic bone cement and the hydrophilic acetabular bone stock. Thus, the long-term adhesive strength between bone and bone cement is decreased resulting in premature aseptic loosening. Accordingly, an amphiphilic bonding system was developed to prevent hydrolytic debonding in the interface bone-to-bone cement. Polyethylene cups were cemented in cadaver sheep hips. The hips were prepared with (n = 10) a multilayer bonding system as well as with an improved monolayer bonding system with (n = 10) and without (n = 10) UV-light hardening. The hips were dynamically loaded (106 cycles; 3 Hz; upper/lower load 1,500/200 N) and afterwards turned out with a defined strength to determine the interface compound strength. Dynamically loaded cemented cups without using the bonding system (n = 10) function as a control group. The interface adhesive strength improved significantly by a factor of 1.9 (using the multilayer bonding system) compared to the unconditioned ones (P ≤ 0.05); for the monolayer bonding system without (with) UV-light hardening the compound strength was 11.9-fold (≥22.2-fold) higher (P ≤ 0.001). The bonding system significantly improves the adhesive strength between bone and bone cement in cemented cup arthroplasty.


  • Die Behandlung femoropatellarer Knorpelschäden mit einem dreidimensionalen Kollagengel: Klinische Ergebnisse im Zwei-Jahres-Verlauf

    by S. Andereya, U. Maus, K. Gavenis, S. Gravius, S. Stanzel, R. Müller-Rath, O. Miltner, T. Mumme, U. Schneider

    Studienziel: Diese prospektive Untersuchung stellt die klinischen Ergebnisse nach Defektdeckung von femoropatellaren Knorpelschäden mit einem dreidimensionalen Kollagengel (CaReS®) vor. Methode: Bei insgesamt 14 Patienten (13 retropatellar, 1 trochlear) wurden isolierte femoropatellare Knorpelschäden durch die Autologe Chondrozyten Transplantation mittels kollagenem Zellträger behandelt. In die Studie wurden ausschließlich Patienten aufgenommen, die die Einschlusskriterien der Arbeitsgemeinschaft „Geweberegeneration und Gewebeersatz“ der DGOOC und DGU erfüllten. Grundlage der klinischen Auswertung bildete das von der International Cartilage Repair Society (ICRS) entwickelte Bewertungsschema und der Brittberg-Score. Dargestellt werden die Ergebnisse bis zu zwei Jahren nach der Operation. Ergebnisse: Die ICRS-IKDC-Scores und der Brittberg-Score zeigten im Beobachtungszeitraum eine statistisch signifikante Verbesserung. Die Einschätzung des objektiven IKDC und der ICRS-Funktionsscore verbesserten sich von präoperativ 0/14 bzw. 2/14 (14,3 %) auf 11/14 (78,6 %) in den Kategorien A/B bzw. I/II nach zwei Jahren. 11 (78,6 %) der Patienten beurteilten das Ergebnis nach zwei Jahren mit sehr gut/gut. Der subjektive IKDC-Score verbesserte sich von präoperativ 32,4 ± 8,4 auf 67,8 ± 27,4 nach zwei Jahren. Schlussfolgerung: Dreidimensionale Trägerstrukturen können eine vielversprechende Weiterentwicklung der ACT zur Behandlung von femoropatellaren Knorpelschäden bedeuten. Langzeituntersuchungen müssen die in dieser Studie gewonnenen positiven Ergebnisse überprüfen.