Cardiac cine CT approaching 1 mSv: implementation and assessment of a 58-ms temporal resolution protocol
Authors:
- 4 May 2020
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (8) , 1583-1591
Abstract
Clinical use of cardiac cine CT imaging is limited by high radiation dose and low temporal resolution. To evaluate a low radiation dose, high temporal resolution cardiac cine CT protocol in human cardiac CT and phantom scans. CT scans of a circulating iodine target were reconstructed using the conventional single heartbeat half-scan (HS, approx. 175 ms temporal resolution) and the 3-heartbeat multi-segment (MS, approx. 58 ms) algorithms. Motion artifacts were quantified by the root-mean-square error (RMSE). Low-dose cardiac cine CT scans were performed in 55 subjects at a tube potential of 80 kVp and current of 80 mA. Image quality of HS and MS scans was assessed by blinded reader quality assessment, left ventricular (LV) free wall motion, and LV ejection rate. Motion artifacts in phantom scans were higher in HS than in MS reconstructions (RSME 188 and 117 HU, respectively; p = 0.001). Median radiation dose in human scans was 1.2 mSv. LV late diastolic filling was observed more frequently in MS than in HS images (42 vs. 26 subjects, respectively; p < 0.001). LV free wall systolic motion was more physiologic and had less error in MS than in HS reconstructions (sum-of-squared errors 34 vs. 45 mm2, respectively; p < 0.001), and LV peak ejection rate was higher in MS than in HS reconstructions (166 vs. 152 mL/s, respectively; p < 0.001). Cardiac cine CT imaging is feasible at a low radiation dose of 1.2 mSv. MS reconstruction showed improved imaging of rapid motion in phantom studies and human cardiac CTs.Keywords
Funding Information
- Clinical Center
This publication has 20 references indexed in Scilit:
- Myocardial strain imaging: review of general principles, validation, and sources of discrepanciesEuropean Heart Journal - Cardiovascular Imaging, 2019
- Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapyHeart Rhythm, 2017
- Multi-institutional evaluation of the indications and radiation dose of functional cardiovascular computed tomography (CCT) imaging in congenital heart diseaseThe International Journal of Cardiovascular Imaging, 2015
- Regional Strain Analysis with Multidetector CT in a Swine Cardiomyopathy Model: Relationship to Cardiac MR Tagging and Myocardial FibrosisRadiology, 2015
- Regional Strain Determination and Myocardial Infarction Detection by Three-Dimensional Echocardiography with Varied Temporal ResolutionEchocardiography, 2014
- Functional analysis by 64-slice CT scanning: prediction of left ventricular dysfunction together with reduction in radiation exposure?The International Journal of Cardiovascular Imaging, 2010
- High temporal resolution SSFP cine MRI for estimation of left ventricular diastolic parametersJournal of Magnetic Resonance Imaging, 2010
- Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320–Detector Row Volume ScannerRadiology, 2010
- Image Quality of Coronary 320-MDCT in Patients With Atrial Fibrillation: Initial ExperienceAmerican Journal of Roentgenology, 2009
- Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily PracticeCirculation, 2006