Abstract
The development and use of new thermal insulation products in many industrial sectors, ranging from building insulations to power generation or satellite applications, requires the accurate knowledge of the radiative properties of the investigated material, i. e. its emissivity. A major objective of the research project “Improvement of emissivity measurements on reflective insulation materials” within the framework of the European Metrology Programme for Innovation and Research was to improve and validate reference techniques for the measurement of the total hemispherical emissivity of low emissivity foils with an absolute measurement uncertainty below 0.03. The calibration and measurement procedures developed within this project shall lead to a significant benefit for industrial manufacturers of reflective foils as well as for the end-users of the industrial instruments used to characterize them.Keywords
Funding Information
- European Metrology Programme for Innovation and Research (16NRM06)
This publication has 9 references indexed in Scilit:
- Assessment of uncertainties for measurements of total near-normal emissivity of low-emissivity foils with an industrial emissometerJournal of Sensors and Sensor Systems, 2021
- Characterization, calibration and validation of an industrial emissometerJournal of Sensors and Sensor Systems, 2019
- Review of PTB Measurements on Emissivity, Reflectivity and Transmissivity of Semitransparent Fiber-Reinforced Plastic CompositesInternational Journal of Thermophysics, 2019
- Nonuniformity determination of infrared imagers by detecting radiance temperatures with the Data Reference Method2018
- A large-area plate radiator with in situ temperature homogenization for thermographic imager calibrationReview of Scientific Instruments, 2018
- Emissivity Measurement Under Vacuum from $4\,\upmu \hbox {m}$ 4 μ m to $100\,\upmu \hbox {m}$ 100 μ m and from $-40\,^{\circ }\hbox {C}$ - 40 ∘ C to $450\,^{\circ }\hbox {C}$ 450 ∘ C at PTBInternational Journal of Thermophysics, 2014
- Handheld Reflective Foil Emissometer with 0.007 Absolute Accuracy at 0.05International Journal of Thermophysics, 2014
- Infrared Emissivity Measurements of Building and Civil Engineering Materials: A New Device for Measuring EmissivityInternational Journal of Thermophysics, 2013
- The determination of the uncertainties of spectral emissivity measurements in air at the PTBMetrologia, 2010