Accuracy of the intermittently scanned continuous glucose monitoring system in critically ill patients: a prospective, multicenter, observational study
Open Access
- 13 October 2022
- journal article
- research article
- Published by Springer Nature in Endocrine
- Vol. 78 (3) , 470-475
Abstract
Objective Continuous glucose monitoring (CGM) has the potential to improve glucose control in the intensive care unit (ICU) setting. We sought to evaluate the accuracy of the intermittently scanned CGM (isCGM) system in critically ill patients. Research design and methods Adult patients were consecutively enrolled from three ICUs from August 2020 to January 2021. The performance of FreeStyle Libre Pro was evaluated against the venous blood glucose samples as a reference. Numerical accuracy was examined by the mean absolute relative difference (MARD), the Bland–Altman analysis, and the International Organization for Standardization criteria. Clinical accuracy was assessed by performing the Clarke and consensus error grid analysis. Results A total of 122 patients were included and 3416 matched glucose pairs were analyzed. The overall MARD was 18.0%, and the highest MARD (33.1%) was observed in the hypoglycemic range (<70 mg/dL). The Bland–Altman analysis revealed a mean bias of −11.7 mg/dL, with the 95% limits of agreement of −73.0 to 49.5 mg/dL. The percentages of isCGM glucose values within ±15%/15, ±20%/20, and ±30%/30 mg/dL were 49.8%, 64.7%, and 84.5%, respectively. The Clarke and consensus error grid analysis showed acceptable clinical accuracy with 98.5% and 98.8% of glucose values falling into zones A and B. Conclusions Our study demonstrated suboptimal overall accuracy of isCGM for critically ill patients. Whether the adjunctive use of isCGM could improve glucose management and health outcomes in the critically ill needs further investigation. Clinical trial registration ChiCTR2100042036, Chinese Clinical Trial Registry.Keywords
This publication has 19 references indexed in Scilit:
- Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patientsJournal of Clinical Monitoring and Computing, 2017
- International Consensus on Use of Continuous Glucose MonitoringDiabetes Care, 2017
- Glucose Measurement in the ICU: Regulatory Intersects Reality*Critical Care Medicine, 2017
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin InjectionsJAMA, 2017
- Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trialThe Lancet, 2016
- Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac SurgeryJournal of Diabetes Science and Technology, 2016
- Continuous Glucose Monitoring Versus Capillary Point-of-Care Testing for Inpatient Glycemic Control in Type 2 Diabetes Patients Hospitalized in the General Ward and Treated With a Basal Bolus Insulin RegimenJournal of Diabetes Science and Technology, 2015
- Continuous glucose control in the ICU: report of a 2013 round table meetingCritical Care, 2014
- Short- and Long-Term Effects of Real-Time Continuous Glucose Monitoring in Patients With Type 2 DiabetesDiabetes Care, 2011
- Intensive Insulin Therapy in Critically Ill PatientsNew England Journal of Medicine, 2001