Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study
Authors:
- 4 March 2021
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 32 (1) , 11-18
Abstract
Purpose Volar locking plates, used in distal radius fracture (DRF), present a risk of injuring extensor tendons with screws penetrating the dorsal cortex of the radius. Actually, even when aiming to use maximum-length unicortical locking screws, some still could be bicortical. We hypothesize the use of only short unicortical screws would allow a proper stabilization of the radial epiphysis without the risk of dorsal cortex penetration. Materials and methods A prospective monocentric non-randomized study was conducted. Patients with DRF (excepted for partial dorsal joint fractures) were treated in group A with short locking epiphyseal screws (16 mm for females, 18 mm for males) and in group B with full-length unicortical locking screws. Ultrasound was done 3 months postoperatively to evaluate the number and length of prominent dorsal screws. X-rays were performed after 6 weeks to assess stability according to volar tilt and radial inclination variations. Results There were 37 patients in group A and 39 in group B with 148 and 156 epiphyseal screws, respectively. In group A, there were 0% of dorsal penetrating screws against 6.5% (10 screws from 8 patients) in group B (p < 0.05). There was no significant difference for the stability between the groups: mean volar tilt variation ( − 0.6° vs. − 0.7°) and mean radial inclination variation ( − 0.4° vs. − 0.4°). Conclusion For a same stability with volar locking plates for DRF, short epiphyseal locking screws should be preferred to full-length unicortical screws in order to prevent extensor tendon injuries. Based on 75% of distal radial average anteroposterior width for each sex, screw lengths of 16 mm for females and 18 mm for males seem to be the length to use. Level of Evidence 2 Prospective, Comparisons made, non-randomized.Keywords
This publication has 32 references indexed in Scilit:
- Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixationJournal of Hand Surgery (European Volume), 2011
- Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesisJournal of Hand Surgery (European Volume), 2009
- Morphometric Analysis of Lister's Tubercle and Its Consequences on Volar Plate Fixation of Distal Radius FracturesThe Journal of Hand Surgery, 2008
- A revolution in the management of fractures of the distal radius?The Journal of Bone and Joint Surgery. British volume, 2008
- Les radiographies simples du poignet et de la mainJournal de Radiologie, 2008
- Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-PlateJournal of Orthopaedic Trauma, 2007
- Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fracturesThe Journal of Bone and Joint Surgery. British volume, 2006
- Two Potential Causes of EPL Rupture after Distal Radius Volar Plate FixationClinical Orthopaedics and Related Research, 2006
- Volar Fixed-Angle Plating of Distal Radius Extension Fractures: Influence of Plate Position on Secondary Loss of Reduction—A Biomechanic Study in a Cadaveric ModelThe Journal of Hand Surgery, 2006
- Stability assessment of distal radius fracturesInjury, 1989