Abstract
Purpose: To compare the effect of two ocular viscosurgical devices (OVDs) on intraocular pressure (IOP) and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model) implantation. Methods: A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC) in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes. Results: Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00). Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05) for both the groups. Conclusion: The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model).Keywords
This publication has 11 references indexed in Scilit:
- Intraocular Pressure after Implantation of the Visian Implantable Collamer Lens With CentraFLOW Without IridotomyAmerican Journal of Ophthalmology, 2013
- Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential ComplicationsJournal of Refractive Surgery, 2011
- Use of viscoelastic substance in ophthalmic surgery — focus on sodium hyaluronateClinical Ophthalmology, 2008
- In vitro behavior of ophthalmic viscosurgical devices during phacoemulsificationJournal of Cataract & Refractive Surgery, 2006
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- Comparison of viscoelastic substances used in phacoemulsificationJournal of Cataract & Refractive Surgery, 1996
- Cytotoxicity of Viscoelastics on Cultured Corneal Epithelial Cells Measured by Plasminogen Activator ReleaseJournal of Refractive Surgery, 1994
- A Comparison of Corneal Endothelial Changes After Use of Healon or Viscoat During PhacoemulsificationAmerican Journal of Ophthalmology, 1993
- Removal of viscoelastic materials after experimental cataract surgery in vitroJournal of Cataract & Refractive Surgery, 1992
- Rheology of HyaluronateActa Oto-Laryngologica, 1987