Sheetal Brar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sheetal Brar has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Sri Ganesh
Department of Phaco and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bangalore, Karnataka, India
32 shared publications- Sri Ganesh
Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India
8 shared publications Megha Gautam
Nethradhama Super Special Eye Hosp, Bangalore, Karnataka, India
5 shared publicationsSmith Snehal Sute
5 shared publicationsSri Ms Ganesh
From the Nethradhama Superspeciality Eye Hospital, Bengaluru, India
4 shared publications- Archana Pawar
Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India
3 shared publications
Latest Publications
- Open Access
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1754-1759
Visual and refractive outcomes and real-world evaluation of patient satisfaction following bilateral implantation of PanOptix Toric intraocular lens implantation
Purpose: To evaluate 12-month visual and refractive outcomes, patient satisfaction, and the real-world experience following bilateral implantation of an Aspheric Trifocal Toric intraocular lens (IOL). Methods: Eligible patients underwent phacoemulsification followed by bilateral implantation of the AcrySof IQ PanOptix toric IOL (Alcon) for age-related cataract. All eyes were targeted at emmetropia using the Barrett TK Toric formula. Post-operative examinations at 6 months included binocular photopic uncorrected and corrected distance, near (40 cm) and intermediate (60 cm) visual acuity assessment, defocus curve testing (+2 to −4 D), reading performance at 40 and 66 cm with Salzburg Reading Desk (SRD), and subjective outcomes, including the IOL SAT quality of vision questionnaire for patient satisfaction and spectacle independence. Result: Thirty patients with a mean age of 60 ± 12 years were included. Twelve months post-op, the mean binocular photopic uncorrected and corrected distance visual acuity (UDVA, CDVA), UNVA, DCNVA, UIVA, and DCIVA were −0.01 ± 0.05, −0.03 ± 0.05, 0.05 ± 0.07, 0.06 ± 0.05, 0.08 ± 0.04, and 0.09 ± 0.04 LogMAR, respectively. Reading performance evaluated at 40 cm and 66 cm showed mean reading speeds of 157.9 ± 44.9 and 159.5 ± 36.63 wpm, respectively ( P = 0). Mean residual sphere, cylinder, and spherical equivalent (SE) were 0.02 ± 0.09, 0.00 ± 0.17, 0.02 ± 0.12 D, respectively. A total of 96.6% (29/30) of patients reported complete freedom from spectacles while working at all distances in all light conditions and rated their satisfaction after surgery as “very satisfied.” No eye required re-rotation of toric IOL or YAG capsulotomy for posterior capsule opacification (PCO) or developed any other sight impeding complication by the end of the follow-up. Conclusion: In the real-world scenario, PanOptix toric IOL allowed complete visual restoration with excellent patient satisfaction and visual quality outcomes. CTRI registration number: CTRI/2020/01/022808
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1754-1759
Open AccessVisual and refractive outcomes and real-world evaluation of patient satisfaction following bilateral implantation of PanOptix Toric intraocular lens implantation
Purpose: To evaluate 12-month visual and refractive outcomes, patient satisfaction, and the real-world experience following bilateral implantation of an Aspheric Trifocal Toric intraocular lens (IOL). Methods: Eligible patients underwent phacoemulsification followed by bilateral implantation of the AcrySof IQ PanOptix toric IOL (Alcon) for age-related cataract. All eyes were targeted at emmetropia using the Barrett TK Toric formula. Post-operative examinations at 6 months included binocular photopic uncorrected and corrected distance, near (40 cm) and intermediate (60 cm) visual acuity assessment, defocus curve testing (+2 to −4 D), reading performance at 40 and 66 cm with Salzburg Reading Desk (SRD), and subjective outcomes, including the IOL SAT quality of vision questionnaire for patient satisfaction and spectacle independence. Result: Thirty patients with a mean age of 60 ± 12 years were included. Twelve months post-op, the mean binocular photopic uncorrected and corrected distance visual acuity (UDVA, CDVA), UNVA, DCNVA, UIVA, and DCIVA were −0.01 ± 0.05, −0.03 ± 0.05, 0.05 ± 0.07, 0.06 ± 0.05, 0.08 ± 0.04, and 0.09 ± 0.04 LogMAR, respectively. Reading performance evaluated at 40 cm and 66 cm showed mean reading speeds of 157.9 ± 44.9 and 159.5 ± 36.63 wpm, respectively ( P = 0). Mean residual sphere, cylinder, and spherical equivalent (SE) were 0.02 ± 0.09, 0.00 ± 0.17, 0.02 ± 0.12 D, respectively. A total of 96.6% (29/30) of patients reported complete freedom from spectacles while working at all distances in all light conditions and rated their satisfaction after surgery as “very satisfied.” No eye required re-rotation of toric IOL or YAG capsulotomy for posterior capsule opacification (PCO) or developed any other sight impeding complication by the end of the follow-up. Conclusion: In the real-world scenario, PanOptix toric IOL allowed complete visual restoration with excellent patient satisfaction and visual quality outcomes. CTRI registration number: CTRI/2020/01/022808
- 14 December 2024
- Published by Springer Nature
- p. 97-103
Main Features of VisuMax 800, Programming and Workflow
- 14 December 2024
- Published by Springer Nature
- p. 97-103
Main Features of VisuMax 800, Programming and Workflow
- Open Access
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2685-2695
Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems
Purpose: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Study Design: Prospective, interventional, 3-arm, randomized comparison study. Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed. Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable. Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems. Ctri Registration Number: CTRI/2022/01/039296.
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2685-2695
Open AccessComparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems
Purpose: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Study Design: Prospective, interventional, 3-arm, randomized comparison study. Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed. Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable. Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems. Ctri Registration Number: CTRI/2022/01/039296.
- 1 July 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (7) , 718-723
Clinical outcomes and rotational stability after implantation of a monofocal toric intraocular lens with textured haptics in normal vs high axial lengths
Purpose: To compare the clinical outcomes and rotational stability after implantation of a toric intraocular lens (IOL) with textured haptics in eyes with normal vs high axial lengths (ALs). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: 2-arm, retrospective comparative study. Methods: This retrospective study included 114 eyes of 114 patients who underwent femtolaser cataract surgery followed by implantation of the HOYA Vivinex Toric monofocal IOL (Model XY1A-SP), of which 62 and 52 eyes belonged to normal (≤23.9 mm) and high (≥24 mm) AL groups, respectively. 1 week and 3 months postoperatively, clinical outcomes and rotational stability of the toric IOL was evaluated. Results: 3 months postoperatively, % eyes achieving refractive astigmatism accuracy within ≤0.50 diopter, was 100% (n = 62) in the normal vs 94% (n = 49) in the high AL group. All eyes that is, 100% (n = 62) in the normal and 96.15% (n = 50) eyes in the high myopia group were P = .80). No significant correlation was observed between AL and white-to-white diameter with 1-week postoperative rotation values. No eye required repositioning of toric IOL for significant misalignment. Conclusions: No significant differences were observed for clinical outcomes and postoperative rotational stability between eyes with normal and high ALs, suggesting excellent rotational stability of the Vivinex Toric IOL with textured haptics in all eyes, irrespective of the preoperative AL measurements.
- 1 July 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (7) , 718-723
Clinical outcomes and rotational stability after implantation of a monofocal toric intraocular lens with textured haptics in normal vs high axial lengths
Purpose: To compare the clinical outcomes and rotational stability after implantation of a toric intraocular lens (IOL) with textured haptics in eyes with normal vs high axial lengths (ALs). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: 2-arm, retrospective comparative study. Methods: This retrospective study included 114 eyes of 114 patients who underwent femtolaser cataract surgery followed by implantation of the HOYA Vivinex Toric monofocal IOL (Model XY1A-SP), of which 62 and 52 eyes belonged to normal (≤23.9 mm) and high (≥24 mm) AL groups, respectively. 1 week and 3 months postoperatively, clinical outcomes and rotational stability of the toric IOL was evaluated. Results: 3 months postoperatively, % eyes achieving refractive astigmatism accuracy within ≤0.50 diopter, was 100% (n = 62) in the normal vs 94% (n = 49) in the high AL group. All eyes that is, 100% (n = 62) in the normal and 96.15% (n = 50) eyes in the high myopia group were P = .80). No significant correlation was observed between AL and white-to-white diameter with 1-week postoperative rotation values. No eye required repositioning of toric IOL for significant misalignment. Conclusions: No significant differences were observed for clinical outcomes and postoperative rotational stability between eyes with normal and high ALs, suggesting excellent rotational stability of the Vivinex Toric IOL with textured haptics in all eyes, irrespective of the preoperative AL measurements.
- Open Access
- 22 June 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (7) , 1056-1063
Feasibility study of treatment of mixed astigmatism with small-incision lenticule extraction (SMILE) by using research software
Purpose: To report the preliminary experience and initial clinical results following SMILE for the treatment of mixed astigmatism. Methods: Thirteen eyes of nine patients with a mean age of 27 ± 4.36 years were included in the series. In 8/13 eyes, myopic SMILE license and in 4/13 eyes, hyperopic SMILE license (available as part of an open/research software) was used for the treatment. The mean follow-up was 9.5 ± 8.7 (0.5–24) months, and the median follow-up was 6 months. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Exploratory study. Results: The mean preoperative sphere, cylinder, and spherical equivalent (SE) were 1.44 ± 1.63, −2.70 ± 2.30, and −0.24 ± 1.14 D, which changed to −0.03 ± 0.30, −0.28 ± 0.48, and −0.18 ± 0.49 D, respectively, 6 months postoperatively. Furthermore, 85% (11/13) eyes were within ± 0.50 D, 92% (12/13) eyes were within ± 1.00 D, while all eyes were within ± 1.50 D of SE correction. All eyes were within ± 1.00 D of cylinder correction. In addition, 92% (12/13) eyes had UDVA better than 20/32, with 54% (7/13) eyes having UDVA 20/20 or better. Safety and efficacy indices were 1.08 and 0.92, respectively. No eyes lost more than 1 line of CDVA. The mean corneal higher order aberrations (HOA) increased from 0.111 ± 0.048 to 0.209 ± 0.056 ( P < 0.001). The mean objective scatter index (OSI) did not show a significant change (pre = 0.71 ± 0.69, 6 months = 0.89 ± 0.20; P = 0.35). Conclusion: Early experience showed that SMILE was feasible for the management of eyes with mixed astigmatism, without any intraoperative complications, unique to the procedure.
- 22 June 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (7) , 1056-1063
Open AccessFeasibility study of treatment of mixed astigmatism with small-incision lenticule extraction (SMILE) by using research software
Purpose: To report the preliminary experience and initial clinical results following SMILE for the treatment of mixed astigmatism. Methods: Thirteen eyes of nine patients with a mean age of 27 ± 4.36 years were included in the series. In 8/13 eyes, myopic SMILE license and in 4/13 eyes, hyperopic SMILE license (available as part of an open/research software) was used for the treatment. The mean follow-up was 9.5 ± 8.7 (0.5–24) months, and the median follow-up was 6 months. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Exploratory study. Results: The mean preoperative sphere, cylinder, and spherical equivalent (SE) were 1.44 ± 1.63, −2.70 ± 2.30, and −0.24 ± 1.14 D, which changed to −0.03 ± 0.30, −0.28 ± 0.48, and −0.18 ± 0.49 D, respectively, 6 months postoperatively. Furthermore, 85% (11/13) eyes were within ± 0.50 D, 92% (12/13) eyes were within ± 1.00 D, while all eyes were within ± 1.50 D of SE correction. All eyes were within ± 1.00 D of cylinder correction. In addition, 92% (12/13) eyes had UDVA better than 20/32, with 54% (7/13) eyes having UDVA 20/20 or better. Safety and efficacy indices were 1.08 and 0.92, respectively. No eyes lost more than 1 line of CDVA. The mean corneal higher order aberrations (HOA) increased from 0.111 ± 0.048 to 0.209 ± 0.056 ( P < 0.001). The mean objective scatter index (OSI) did not show a significant change (pre = 0.71 ± 0.69, 6 months = 0.89 ± 0.20; P = 0.35). Conclusion: Early experience showed that SMILE was feasible for the management of eyes with mixed astigmatism, without any intraoperative complications, unique to the procedure.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 572-577
Changes in endothelial cell density after conventional phacoemulsification and FLACS in eyes with dense cataracts
Purpose: To compare the safety, effectiveness, and changes in endothelial cell density (ECD) after standard phacoemulsification and femtosecond laser-assisted cataract surgery (FLACS) in dense cataracts (Lens Opacities Classification System III grade 3.0 NO and above). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Prospective, randomized, comparative study. Method: 100 eyes of 100 patients were randomly assigned to either conventional phacoemulsification surgery (CPS) or FLACS (LENSAR Laser System) using predefined patterns of nuclear fragmentations. Measured outcomes included intraoperative phacoemulsification time, irrigation fluid volume, surgical time, and complication rates. ECD was evaluated at baseline, 2 weeks, and 6 months postoperatively. Results: The CPS group had significantly higher mean total phacoemulsification time (11.17 ± 6.5 seconds vs 8.03 ± 3.77 seconds), effective phacoemulsification time (6.14 ± 3.62 seconds vs 4.42 ± 2.07 seconds), and total surgical time (8.18 ± 2.36 minutes vs 7.11 ± 1.55 minutes) than the FLACS group (P < .001). Volume of irrigation fluid was comparable between the 2 groups (CPS, 36.7 ± 12.18 mL; FLACS, 38.64 ± 13.73 mL (P = .45). Mean corneal edema score and central corneal thickness values on postoperative day 1 were significantly higher for the CPS group. At 6 months, % ECD loss was significantly higher in the CPS group (16.08%) vs the FLACS group (12.8%) (P < .001). 3 eyes in the CPS group had wound burns of varying severity. Conclusions: FLACS with customized nuclear fragmentation patterns resulted in significantly less intraoperative phacoemulsification time, surgical time, and endothelial cell loss compared with conventional phacoemulsification when treating dense cataracts. Trial Registration Number: CTRI/2021/12/038887.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 572-577
Changes in endothelial cell density after conventional phacoemulsification and FLACS in eyes with dense cataracts
Purpose: To compare the safety, effectiveness, and changes in endothelial cell density (ECD) after standard phacoemulsification and femtosecond laser-assisted cataract surgery (FLACS) in dense cataracts (Lens Opacities Classification System III grade 3.0 NO and above). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Prospective, randomized, comparative study. Method: 100 eyes of 100 patients were randomly assigned to either conventional phacoemulsification surgery (CPS) or FLACS (LENSAR Laser System) using predefined patterns of nuclear fragmentations. Measured outcomes included intraoperative phacoemulsification time, irrigation fluid volume, surgical time, and complication rates. ECD was evaluated at baseline, 2 weeks, and 6 months postoperatively. Results: The CPS group had significantly higher mean total phacoemulsification time (11.17 ± 6.5 seconds vs 8.03 ± 3.77 seconds), effective phacoemulsification time (6.14 ± 3.62 seconds vs 4.42 ± 2.07 seconds), and total surgical time (8.18 ± 2.36 minutes vs 7.11 ± 1.55 minutes) than the FLACS group (P < .001). Volume of irrigation fluid was comparable between the 2 groups (CPS, 36.7 ± 12.18 mL; FLACS, 38.64 ± 13.73 mL (P = .45). Mean corneal edema score and central corneal thickness values on postoperative day 1 were significantly higher for the CPS group. At 6 months, % ECD loss was significantly higher in the CPS group (16.08%) vs the FLACS group (12.8%) (P < .001). 3 eyes in the CPS group had wound burns of varying severity. Conclusions: FLACS with customized nuclear fragmentation patterns resulted in significantly less intraoperative phacoemulsification time, surgical time, and endothelial cell loss compared with conventional phacoemulsification when treating dense cataracts. Trial Registration Number: CTRI/2021/12/038887.
- Open Access
- 1 January 2024
- Published by Medknow in Taiwan Journal of Ophthalmology
- Vol. 14 (1) , 70-77
Lamellar surgeries with SMILE-derived lenticules
PURPOSE: Lamellar surgeries with SMILE lenticules are an evolving field of refractive surgery. This chapter intends to discuss the reported clinical results of using SMILE derived lenticules in terms of feasibility, safety and predictability; or the potential management of hyperopia, keratoconus, SMILE ectasia and presbyopia. MATERIALS AND METHODS: Donor SMILE lenticules were prepared under microscope tocreate doughnut shaped lenticules. For hyperopia, this tissue was then inserted into afemtosecond laser enabled pocket created using VisuMax FS Laser at a depth of 160µm. For ectasia induced by keratoconus and post refractive procedure (SMILE), 0.23% riboflavin dye was instilled into the interface and then lenticule was inserted followed by exposure to UV-A radiation with total energy of 6.3 J. RESULTS: Spherical equivalent (S.E.) of within ± 0.5 D was observed in 50% (n=21) eyes and within 1 D was seen in 71% eyes treated for hyperopia. A significant increase in the K mean anterior, central corneal thickness, Q-value and corneal aberrations was seen 2 weeks post-op. Clinical improvement in terms of S.E. and uncorrected distance visual acuity in eyes treated for ectasia after keratoconus and post refractive procedure (SMILE) was seen. CONCLUSION: With the ample availability of SMILE- derived lenticules, researchers are exploring the possibility of using this tissue for the treatment of various refractive and corneal conditions.
- 1 January 2024
- Published by Medknow in Taiwan Journal of Ophthalmology
- Vol. 14 (1) , 70-77
Open AccessLamellar surgeries with SMILE-derived lenticules
PURPOSE: Lamellar surgeries with SMILE lenticules are an evolving field of refractive surgery. This chapter intends to discuss the reported clinical results of using SMILE derived lenticules in terms of feasibility, safety and predictability; or the potential management of hyperopia, keratoconus, SMILE ectasia and presbyopia. MATERIALS AND METHODS: Donor SMILE lenticules were prepared under microscope tocreate doughnut shaped lenticules. For hyperopia, this tissue was then inserted into afemtosecond laser enabled pocket created using VisuMax FS Laser at a depth of 160µm. For ectasia induced by keratoconus and post refractive procedure (SMILE), 0.23% riboflavin dye was instilled into the interface and then lenticule was inserted followed by exposure to UV-A radiation with total energy of 6.3 J. RESULTS: Spherical equivalent (S.E.) of within ± 0.5 D was observed in 50% (n=21) eyes and within 1 D was seen in 71% eyes treated for hyperopia. A significant increase in the K mean anterior, central corneal thickness, Q-value and corneal aberrations was seen 2 weeks post-op. Clinical improvement in terms of S.E. and uncorrected distance visual acuity in eyes treated for ectasia after keratoconus and post refractive procedure (SMILE) was seen. CONCLUSION: With the ample availability of SMILE- derived lenticules, researchers are exploring the possibility of using this tissue for the treatment of various refractive and corneal conditions.
- 1 August 2023
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 39 (8) , 546-554
Comparison of Dynamic Vault Changes Following Implantation of Two Different Models of Phakic Intraocular Lenses
Purpose: To compare the dynamic vault range (the difference in the central vault height from scotopic to photopic light condition) after implantation of the ICL/TICL (STAAR Surgical) and Eyecryl phakic/Eyecryl phakic toric intraocular lens (IOL) (Biotech Healthcare). Methods: This retrospective study included patients with myopia or myopic astigmatism eligible for phakic IOL implantation with either the ICL/TICL or Eyecryl phakic/Eyecryl phakic toric IOL. Vault changes in varying light conditions (scotopic, mesopic, and photopic) were assessed using an anterior segment optical coherence tomography–based tomographer and dynamic vault range (DVR) was compared between the two groups. Results: A total of 60 eyes from 36 patients (30 eyes in each group) with a mean age of 28.63 ± 6.36 years were included. The mean postoperative follow-up at the time of assessment was 9.4 ± 5.3 and 8.9 ± 5.28 months ( P = .75) in the ICL and Eyecryl groups, respectively. The mean values of scotopic, mesopic, and photopic vault were 490.56 ± 238.64, 453.56 ± 224.30, and 373.96 ± 200.24 μm in the ICL group and 515.46 ± 174.34, 490.26 ± 184.04, 450.43 ± 173.92 μm in the Eyecryl group ( P = .32, .24, and .05, respectively). The DVR was 116.6 ± 59.29 μm in the ICL group versus 65.03 ± 31.78 μm in the Eyecryl group ( P < .001). Conclusions: The Eyecryl phakic IOL showed significantly fewer light-induced changes in the central vault height (DVR) compared to the ICL, which may be attributed to the difference in the material of the two phakic IOL models. This may be clinically significant in eyes with low postoperative vaults with respect to their follow-up and risk assessment of cataractogenesis in the long term. [ J Refract Surg. 2023;39(8):546–554.]
- 1 August 2023
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 39 (8) , 546-554
Comparison of Dynamic Vault Changes Following Implantation of Two Different Models of Phakic Intraocular Lenses
Purpose: To compare the dynamic vault range (the difference in the central vault height from scotopic to photopic light condition) after implantation of the ICL/TICL (STAAR Surgical) and Eyecryl phakic/Eyecryl phakic toric intraocular lens (IOL) (Biotech Healthcare). Methods: This retrospective study included patients with myopia or myopic astigmatism eligible for phakic IOL implantation with either the ICL/TICL or Eyecryl phakic/Eyecryl phakic toric IOL. Vault changes in varying light conditions (scotopic, mesopic, and photopic) were assessed using an anterior segment optical coherence tomography–based tomographer and dynamic vault range (DVR) was compared between the two groups. Results: A total of 60 eyes from 36 patients (30 eyes in each group) with a mean age of 28.63 ± 6.36 years were included. The mean postoperative follow-up at the time of assessment was 9.4 ± 5.3 and 8.9 ± 5.28 months ( P = .75) in the ICL and Eyecryl groups, respectively. The mean values of scotopic, mesopic, and photopic vault were 490.56 ± 238.64, 453.56 ± 224.30, and 373.96 ± 200.24 μm in the ICL group and 515.46 ± 174.34, 490.26 ± 184.04, 450.43 ± 173.92 μm in the Eyecryl group ( P = .32, .24, and .05, respectively). The DVR was 116.6 ± 59.29 μm in the ICL group versus 65.03 ± 31.78 μm in the Eyecryl group ( P < .001). Conclusions: The Eyecryl phakic IOL showed significantly fewer light-induced changes in the central vault height (DVR) compared to the ICL, which may be attributed to the difference in the material of the two phakic IOL models. This may be clinically significant in eyes with low postoperative vaults with respect to their follow-up and risk assessment of cataractogenesis in the long term. [ J Refract Surg. 2023;39(8):546–554.]
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 790-794
Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
Purpose: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Method: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. Results: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). Conclusions: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. Trial Registration Number: CTRI/2021/11/038053.
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 790-794
Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
Purpose: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Method: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. Results: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). Conclusions: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. Trial Registration Number: CTRI/2021/11/038053.
- Open Access
- 17 May 2023
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 71 (5) , 2251-2253
A new intraocular lens marker to guide the implantation of toric intraocular lenses in small and mid-dilating pupils
Insufficient pupillary dilatation is a significant challenge during cataract surgery, as it increases the risk of various intraoperative complications. Implantation of toric intraocular lenses (TIOL) is particularly difficult in eyes with small pupils, as the toric marks are provided in the periphery of the IOL optic, making the visualization of the same difficult for proper alignment. Attempts at visualizing these marks using a second instrument such as a dialler or iris retractor lead to additional manipulations in the anterior chamber resulting in increased chances of postoperative inflammation and intraocular pressure rise. A new intraocular lens (IOL) marker to guide the implantation of TIOLs in eyes with small pupils is described, which can potentially be beneficial in achieving accurate alignment of toric IOLs in small pupils, without the need for additional manipulations, thus improving safety, efficacy, and success rates of TIOL implantation in these eyes.
- 17 May 2023
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 71 (5) , 2251-2253
Open AccessA new intraocular lens marker to guide the implantation of toric intraocular lenses in small and mid-dilating pupils
Insufficient pupillary dilatation is a significant challenge during cataract surgery, as it increases the risk of various intraoperative complications. Implantation of toric intraocular lenses (TIOL) is particularly difficult in eyes with small pupils, as the toric marks are provided in the periphery of the IOL optic, making the visualization of the same difficult for proper alignment. Attempts at visualizing these marks using a second instrument such as a dialler or iris retractor lead to additional manipulations in the anterior chamber resulting in increased chances of postoperative inflammation and intraocular pressure rise. A new intraocular lens (IOL) marker to guide the implantation of TIOLs in eyes with small pupils is described, which can potentially be beneficial in achieving accurate alignment of toric IOLs in small pupils, without the need for additional manipulations, thus improving safety, efficacy, and success rates of TIOL implantation in these eyes.