Abstract
This paper presents result of a project that enabled older operating motors to be removed from service and tested for efficiency under laboratory conditions, with the displaced motors being replaced by new National Electrical Manufacturers Association premium motors. The objective of the project is to determine the efficiency of a population of motors in operation before the Energy Policy Act of 1992 and to investigate if there was economic justification in replacing such motors with new ones. The economic benefit of repair/replace is computed at the tested partial-load efficiency of the motors. In addition, results are presented that show the load point at which maximum efficiency occurs for each motor. The differences in the partial-load characteristics of the old and new motors are also discussed.Keywords
This publication has 7 references indexed in Scilit:
- The Economics of Pre-EPAct Motors Operating in IndustryConference Record of 2007 Annual Pulp and Paper Industry Technical Conference, 2007
- Assessing the impacts of rewind and repeated rewinds on induction motors: is an opportunity for Re-designing the machine being wasted?IEEE Transactions on Industry Applications, 2006
- Energy-efficient induction motors-performance characteristics and life-cycle cost comparison for centrifugal loads2002
- Energy Policy Act of 1992 review as it pertains to AC induction motors2002
- Efficiency and reliability assessments of retrofitted high-efficiency motors2002
- Efficiency of electric motors under practical conditionsPower Engineering Journal, 2001
- Applying Energy-Efficient Motors in the Petrochemical industryIEEE Industry Applications Magazine, 1997