Effects of storage time and temperature on coagulation tests and factors in fresh plasma
Authors:
Open Access
- 27 January 2014
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 4 (1) , 3868
Abstract
Coagulation tests and factors measurements have been widely applied in clinical practice. Pre-analytical conditions are very important in laboratory assessment.Here,we aim to determine the effects of storage time and temperature on activated partial thromboplastin time (APTT), fibrinogen (Fbg), prothrombin time (PT), the international normalized ratio (INR), thrombin time (TT), factor VIII activity (FVIII:C) and factor IX activity (FIX:C) in fresh plasma. Seventy-two blood samples were tested after storage for 0 (baseline), 2, 4, 6, 8, 12 and 24 h at 25°C (room temperature) and 4°C (refrigeration) in two centers. The mean percentage change of greater than 10% and the numbers of samples with greater than 10% percentage changes more than 25% were used to determine clinically relevant difference. We demonstrated that samples for Fbg, PT/INR and TT could be safely stored for ≤24 h; FVIII:C for ≤2 h; FIX:C for ≤4 h both at 4°C and 25°C; and APTT for ≤12 h at 4°C and ≤8 h at 25°C.Keywords
This publication has 20 references indexed in Scilit:
- Influence of temperature and storage duration on measurement of activated partial thromboplastin time, D‐dimers, fibrinogen, prothrombin time and thrombin time, in citrate‐anticoagulated whole blood specimensInternational Journal of Laboratory Hematology, 2013
- Stability study of 81 analytes in human whole blood, in serum and in plasmaClinical Biochemistry, 2012
- Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimerBlood Coagulation & Fibrinolysis, 2011
- Coagulation factor content of plasma produced from whole blood stored for 24 hours at ambient temperature: results from an international multicenter BEST Collaborative studyTransfusion, 2011
- Stability of coagulation factors in plasma prepared after a 24‐hour room temperature holdTransfusion, 2010
- Evaluation and comparison of coagulation factor activity in fresh‐frozen plasma and 24‐hour plasma at thaw and after 120 hours of 1 to 6°C storageTransfusion, 2009
- Stability of coagulation assays performed in plasma from citrated whole blood transported at ambient temperatureThrombosis and Haemostasis, 2008
- Thawing Procedures and the Time Course of Clotting Factor Activity in Fresh-Frozen Plasma: A Controlled Laboratory InvestigationAnesthesia & Analgesia, 2006
- Platelet-dependent coagulation assays for factor VIII efficacy measurement after substitution therapy in patients with haemophilia APlatelets, 2006
- Preanalytical Variables and Off-Site Blood Collection: Influences on the Results of the Prothrombin Time/International Normalized Ratio Test and Implications for Monitoring of Oral Anticoagulant TherapyClinical Chemistry, 2005