Epitope Specificity and IgG Subclass Distribution of Autoantibodies to Cardiac Troponin
Open Access
- 1 March 2013
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 59 (3) , 512-518
Abstract
BACKGROUND: Autoantibodies to cardiac troponins (cTnAAbs) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays for the diagnosis of myocardial infarction. Therefore, we determined the cTnI binding sites and IgG subclasses of circulating cTnAAbs. METHODS: We studied epitope specificity with sandwich-type immunoassays by measuring the recovery of troponin complex added to 10 cTnAAb-negative and 10 cTnAAb-positive sera from healthy volunteers. To study the IgG subclasses, we analyzed admission and 3-month follow-up sera from chest pain patients with a reference assay measuring total IgG (14 cTnAAb negative and 14 cTnAAb positive at 3 months) and with 4 subclass-specific assays measuring exclusively IgG subclasses 1–4. RESULTS: Mean recoveries of troponin complex in cTnAAb-positive samples for single cTnI epitopes ranged from 37% to 211%, being lowest for the cTnI midfragment (aa 30–110). However, the lowest sample-specific recoveries, 4%–92%, showed that none of the studied epitopes completely escaped the cTnAAb-related interference. Eight chest pain patients of the cTnAAb-positive group became positive between sampling points, and according to all 5 cTnAAb assays, specific signals were generally higher at follow-up. IgG4, with the highest prevalence, was detected in 68% of samples in the cTnAAb-positive group. CONCLUSIONS: IgG subclass studies confirm that cTnAAb formation may be triggered/boosted in acute cardiac events. This new information about the epitope specificity of cTnAAbs should be used to reevaluate existing recommendations regarding use of midfragment epitopes in cTnI assays. To circumvent the negative interference of the highly heterogeneous cTnAAbs, use of 3 or more unconventionally selected epitopes should be considered.Keywords
Funding Information
- DIA-NET
- Graduate School of Advanced Diagnostic Technologies and Applications
This publication has 27 references indexed in Scilit:
- Troponin-Specific Autoantibody Interference in Different Cardiac Troponin I Assay ConfigurationsClinical Chemistry, 2012
- Multiple immunoassay systems are negatively interfered by circulating cardiac troponin I autoantibodiesClinical and Experimental Medicine, 2011
- Circulating Cardiac Troponin‐I Autoantibodies in Human Plasma and SerumAnnals of the New York Academy of Sciences, 2009
- Prevalence of Autoantibodies to Cardiac Troponin T in Healthy Blood DonorsClinical Chemistry, 2009
- Autoantibodies to Cardiac Troponin Associate with Higher Initial Concentrations and Longer Release of Troponin I in Acute Coronary Syndrome PatientsClinical Chemistry, 2009
- Potential role of antibodies against cardiac Kv channel-interacting protein 2 in dilated cardiomyopathyAmerican Heart Journal, 2008
- Universal definition of myocardial infarction: Kristian Thygesen, Joseph S. Alpert and Harvey D. White on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Redefinition of Myocardial InfarctionEuropean Heart Journal, 2007
- Autoantibodies to cardiac troponin I in patients with idiopathic dilated and ischemic cardiomyopathyInternational Journal of Cardiology, 2007
- Negative Interference in Cardiac Troponin I Immunoassays from a Frequently Occurring Serum and Plasma ComponentClinical Chemistry, 2003
- Quality Specifications for Cardiac Troponin AssaysClinical Chemistry and Laboratory Medicine (CCLM), 2001