TSTanja Savukoski

Tanja Savukoski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tanja Savukoski has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Elevation of cardiac troponins measured after recreational resistance training

    by Tanja Savukoski, Laura Mehtälä, Bertil Lindahl, Per Venge, Kim Pettersson


  • Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference

    by Tanja Savukoski, Jenna Jacobino, Päivi Laitinen, Bertil Lindahl, Per Venge, Noora Ristiniemi, Saara Wittfooth, Kim Pettersson

    Background: Cardiac troponins (cTnI and cTnT) are the recommended biomarkers of myocardial infarction. As cTn-specific autoantibodies (cTnAAb) can interfere with the cTn detection by state-of-the-art cTnI assays, our objective was to develop a sensitive cTnI immunoassay free from this analytical interference. Methods: The assay used antibody-coated spots containing three capture Mabs/Fabs directed against the N-terminus, midfragment and C-terminus of cTnI and a europium chelate-labeled tracer Mab against the C-terminus. Following a 3-h sample incubation and washing, cTnI was quantified by time-resolved fluorometry. Results: The limit of detection (LoD) was 2.9 ng/L and the assay was linear up to 50,000 ng/L. The total precision of 10% CV was not reached, but 20% CV was reached at 10 ng/L. Mean cTnI (10–50,000 ng/L) recoveries were 100% and 119% in three cTnAAb-positive and two cTnAAb-negative individuals, respectively, verifying the interference resistance of the antibody design used. On average, Architect hs-cTnI assay gave seven-fold higher cTnI concentrations than the new assay but the correlation between the assays was good (r=0.958). Of apparently healthy individuals (n=159), 18% had measurable cTnI values (>LoD) and 10% were cTnAAb-positive. The proportion of measurable cTnI values, however, was significantly higher in cTnAAb-positive individuals (13/16, median cTnI 8.5 ng/L) than in cTnAAb-negative individuals (15/143, median cTnI Conclusions: Although the developed sensitive cTnI assay without cTnAAb interference takes too long for diagnostic purposes, it could serve as an important analytical tool for exploring the impact of cTnAAbs for cTn testing and for unraveling the etiology behind cTn-related autoimmune responses.


  • Autoantibody prevalence with an improved immunoassay for detecting cardiac troponin-specific autoantibodies

    by Tanja Savukoski, Tuomo Ilva, Juha Lund, Pekka Porela, Noora Ristiniemi, Saara Wittfooth, Kim Pettersson

    Cardiac troponin-specific autoantibodies (cTnAAb) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays used for the diagnosis of myocardial infarction (MI). Here, an improved version of a previous autoantibody assay was validated and used to evaluate the cTnAAb prevalence in a cohort of consecutive chest pain patients presenting to an emergency department.Admission samples from 510 patients with suspected MI were analyzed in parallel with two sandwich-type cTnAAb assays based on different cTnI epitopes used to capture cardiac troponin-bound cTnAAbs.Sample-specific backgrounds were lower for the new assay than for the old assay (median 1225 vs. 2693 counts, p<0.001). Net signals of cTnAAb-positive samples were higher for the new assay than for the old assay (median 5076 vs. 3921 counts, p<0.001). Of all patients, 9.2% were cTnAAb-positive for the new assay and 7.3% for the old assay (p=0.013). Previous cardiac problems were not associated with cTnAAb status and cTnAAb status did not correlate with the 12-month outcome.With our new and more sensitive autoantibody assay, approximately one out of ten patients who presented to the initial cardiac triage had detectable amounts of cTnAAbs in the circulation. Because these cTnAAbs can interfere with state-of-the-art cTnI assays, their high prevalence should be acknowledged by clinical chemists, physicians, and kit manufacturers.


  • Open Access

    Epitope Specificity and IgG Subclass Distribution of Autoantibodies to Cardiac Troponin

    by Tanja Savukoski, Aleksandra Twarda, Sanna Hellberg, Noora Ristiniemi, Saara Wittfooth, Juha Sinisalo, Kim Pettersson

    BACKGROUND: Autoantibodies to cardiac troponins (cTnAAbs) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays for the diagnosis of myocardial infarction. Therefore, we determined the cTnI binding sites and IgG subclasses of circulating cTnAAbs. METHODS: We studied epitope specificity with sandwich-type immunoassays by measuring the recovery of troponin complex added to 10 cTnAAb-negative and 10 cTnAAb-positive sera from healthy volunteers. To study the IgG subclasses, we analyzed admission and 3-month follow-up sera from chest pain patients with a reference assay measuring total IgG (14 cTnAAb negative and 14 cTnAAb positive at 3 months) and with 4 subclass-specific assays measuring exclusively IgG subclasses 1–4. RESULTS: Mean recoveries of troponin complex in cTnAAb-positive samples for single cTnI epitopes ranged from 37% to 211%, being lowest for the cTnI midfragment (aa 30–110). However, the lowest sample-specific recoveries, 4%–92%, showed that none of the studied epitopes completely escaped the cTnAAb-related interference. Eight chest pain patients of the cTnAAb-positive group became positive between sampling points, and according to all 5 cTnAAb assays, specific signals were generally higher at follow-up. IgG4, with the highest prevalence, was detected in 68% of samples in the cTnAAb-positive group. CONCLUSIONS: IgG subclass studies confirm that cTnAAb formation may be triggered/boosted in acute cardiac events. This new information about the epitope specificity of cTnAAbs should be used to reevaluate existing recommendations regarding use of midfragment epitopes in cTnI assays. To circumvent the negative interference of the highly heterogeneous cTnAAbs, use of 3 or more unconventionally selected epitopes should be considered.


  • Troponin-Specific Autoantibody Interference in Different Cardiac Troponin I Assay Configurations

    by Tanja Savukoski, Emilia Engström, Janne Engblom, Noora Ristiniemi, Saara Wittfooth, Bertil Lindahl, Kai M Eggers, Per Venge, Kim Pettersson

    BACKGROUND: Autoantibodies to cardiac troponins (cTnAAb) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays. The aim of this study was to explore the degree of cTnAAb interference in different cTnI assay configurations.METHODS: Ternary troponin complex was added into samples (serum or plasma, n = 132, 68% cTnAAb positive) from individuals without known cardiac conditions. The recovery of cTnI was then measured with 6 investigational cTnI assays (2, 3, or 4 antibodies per assay). Three of these assays were then selected for further comparison by use of samples (plasma, n = 210, 33% cTnAAb positive) from non–ST-elevation acute coronary syndrome patients in the FRISC-II (FRagmin/Fast Revascularisation during InStability in Coronary artery disease) cohort. Finally, these results were compared to those obtained with 3 commercial cTnI assays.RESULTS: Analytical recoveries varied widely among the 6 investigational assays. Notably the low recoveries (median 9%) of the midfragment-targeting reference assay were normalized (median 103%) with the use of the 4-antibody assay construct (3 capture, 1 tracer antibody) with only 1 antibody against a midfragment epitope. Reduced analytical recoveries correlated closely with measured autoantibody amounts. cTnI concentrations from cTnAAb-positive patient samples determined with 3 investigational assays confirmed the reduced concentrations expected from the low analytical recoveries. The results from the commercial cTnI assays with antibody selections representative for contemporary assay constructs revealed a similar underestimation (up to 20-fold) of cTnI in cTnAAb-positive samples.CONCLUSIONS: A novel cTnI assay deviating from the conventional IFCC-recommended midfragment approach substantially improves cTnI detection in samples containing cTnAAbs.