Torsional Properties Of New And Used Rotary K3 NiTi Files
Authors:
- Ghassan YaredGYGhassan Yared
- Gajanan K. KulkarniGKGajanan K. Kulkarni
- Fadia GhossaynFGFadia Ghossayn
- 1 August 2003
- journal article
- research article
- Published by Wiley in Australian Endodontic Journal
- Vol. 29 (2) , 75-78
Abstract
The purpose of this study was to compare torque (gcm) and angle of rotation (degrees) at fracture of new and used NiTi K3 .04 rotary instruments. The relation between size of instrument and torque at fracture was also investigated. The torque and angle of rotation at fracture of new and used NiTi K3 .04 rotary instruments sizes 15 to 40 were determined according to ANSI/ADA Specification No. 28. Analysis of variance was used to compare the torque and angle of rotation at fracture among the different sizes of the new instruments and between new and used instruments of the same size (α = 0.05). The relationship between torque at fracture and size of instrument was determined with a regression analysis. Torque at fracture of the new instruments increased significantly with the diameter (p < 0.05). The used instruments, sizes 25 to 40, had significantly lower torque at fracture values compared to the new ones (p < 0.05). The used instruments, sizes 20 and 35 had significantly lower angle of rotation at fracture compared to the new ones (p < 0.05). A stronger relationship was found between the size of the file and the torque at fracture for the new instruments (p < 0.0001) compared to the used ones (p < 0.0001). The results of the present study suggested that the torque at fracture values of new instruments increased significantly with the diameter. The results also suggested that repeated use of .04 K3 instruments affected mainly the torque at fracture.Keywords
This publication has 13 references indexed in Scilit:
- Dynamic torque and apical forces of ProFile .04 rotary instruments during preparation of curved canalsInternational Endodontic Journal, 2002
- Failure of ProFile instruments used with high and low torque motorsInternational Endodontic Journal, 2001
- Influence of Structure on Nickel-Titanium Endodontic Instruments FailureJournal of Endodontics, 2001
- Influence of rotational speed, torque and operator’s proficiency on ProFile failuresInternational Endodontic Journal, 2001
- Cyclic fatigue of ProFile rotary instruments after clinical useInternational Endodontic Journal, 2000
- Torque During Canal Instrumentation Using Rotary Nickel-Titanium FilesJournal of Endodontics, 2000
- Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic filesJournal of Endodontics, 1997
- Cyclic fatigue testing of nickel-titanium endodontic instrumentsJournal of Endodontics, 1997
- Torsional testing of the lightspeed nickel-titanium instrument systemJournal of Endodontics, 1996
- Torsional and stiffness properties of canal master U stainless steel and nitinol instrumentsJournal of Endodontics, 1994