Abstract
Six-port interferometers are of great interest for displacement and vibration measurements in industrial as well as medical applications. However, they show offsets as well as amplitude and phase imbalances in their differential in-phase and quadrature signals, leading to inaccuracies of the measured displacement. If a very slow moving or vibrating target has to be monitored, an additional phase shifter for calibration is needed, so that the system's errors can be compensated. A method for calculation and compensation of errors is presented and a compact and cost-efficient implementation of a phase shifter for 24 GHz Six-port interferometers is shown.Keywords
This publication has 4 references indexed in Scilit:
- A Compact, Versatile Six-Port Radar Module for Industrial and Medical ApplicationsJournal of Electrical and Computer Engineering, 2013
- Data-Based Quadrature Imbalance Compensation for a CW Doppler Radar SystemIEEE Transactions on Microwave Theory and Techniques, 2013
- Six-Port Radar Sensor for Remote Respiration Rate and Heartbeat Vital-Sign MonitoringIEEE Transactions on Microwave Theory and Techniques, 2013
- A six-port interferometer based micrometer-accuracy displacement and vibration measurement radar2012