Purpose This study aims to determine the mean and 75th percentile entrance skin dose (ESDcal) from anteroposterior (AP) chest X-rays using machine parameters (indirect method). Also, a comparison was made between the ESDcal and already determined thermoluminescent dosimeter (TLD) measurements (ESDTLD) from a previous study from the same patients’ data. In addition, the results were compared to similar articles, where the direct and indirect methods were used in estimating ESD to newborns. Materials and methods The study determined the digital radiography (DR) X-ray machine output using a calibrated XR Multidetector (silicon photodiode). X-ray machine milliampere-seconds (mAs), peak kilovoltage (kVp), focus to detector distance (FDD) and focus to skin distance (FSD) were used from a previous study. The mean kVp and mAs were 56.63 (52–60) and 5.7 (5–6.3) and the patient thickness was 9.5 (8–11.5) cm. Results The mean ESDs of the newborn between 0 and 28 days were 0.67 ± 0.09 mGy, and the 75th percentile was 0.75 mGy. The effective dose (E) for the 40 patients was 0.19 mSv and the estimated prenatal cancer risk ranged from (5–24.7) 10−6 Sv−1. The variation between the indirect and the direct methods for assessing ESD was 39.6 (33.7–45.1)%. Conclusion The 75th percentile ESD was the highest compared to the American College of Radiology–American Association of Physicists in Medicine–Society for Pediatric Radiology (ACR–AAPM–SPR), European Commission (EC) and United Kingdom (UK) reports. Comparison of both methods for assessing ESD was within 40% as compared to other studies. Based on the above results, the indirect method can be implemented for clinical dose audit.Keywords
This publication has 20 references indexed in Scilit:
- Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, IranGlobal Journal of Health Science, 2015
- Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging systemJournal of Medical Physics, 2015
- Short-term impact of pictorial posters and a crash course on radiographic errors for improving the quality of paediatric chest radiographs in an unsupervised unit — a pilot study for quality-assurance outreachPediatric Radiology, 2014
- Organ doses and effective doses in pediatric radiography: Patient-dose survey in finlandActa Radiologica, 2009
- Radiation Exposure to Premature Infants in a Neonatal Intensive Care Unit in TurkeyKorean Journal of Radiology, 2008
- Radiation doses to patients undergoing standard radiographic examinations: a comparison between two methodsBritish Journal of Radiology, 2007
- Estimation of Radiation Dose during Diagnostic X-Ray Examinations of Newborn Babies and 1-Year-Old InfantsMedical Principles and Practice, 2006
- Radiation dose quantities and risk in neonates in a special care baby unitBritish Journal of Radiology, 2002
- Key factors in the optimization of paediatric X-ray practiceBritish Journal of Radiology, 2001
- Neonatal chest and abdominal radiation dosimetry: a comparison of two radiographic techniquesBritish Journal of Radiology, 2001