AOAkintayo Daniel Omojola

Akintayo Daniel Omojola

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Akintayo Daniel Omojola has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Michael Onoriode Akpochafor

    Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria

    6 shared publications
  • Samuel Olaolu Adeneye

    NSIA - LUTH Cancer Center, Lagos University Teaching Hospital, Lagos, Nigeria; Department of Radiation Biology, Radiotherapy and Radiodiagnosis, College of Medicine, University of Lagos, Lagos, Nigeria

    5 shared publications
  • Samuel Olaolu Adeneye

    Department of Radiation Biology, Radiotherapy and Radiodiagnosis, College of Medicine, University of Lagos, Idi-Araba, Nigeria

    4 shared publications
  • Azuka Anthonio Agboje

    Department of Radiology, Medical Physics Unit, Federal Medical Centre Asaba, Asaba, Nigeria

    3 shared publications
  • Isiaka Olusola Akala

    Department of Radiology, Lagos University Teaching Hospital, Ikeja, Nigeria

    3 shared publications
  • Michael Onoriode Akpochafor

    Department of Radiation Biology, Radiotherapy and Radiodiagnosis, College of Medicine, University of Lagos, Idi-Araba, Nigeria

    3 shared publications

Latest Publications

  • Open Access

    Sonographic biometry of apparently normal parotid gland among adults in Asaba, South-South Nigeria

    by Ugwu Stephen Mbonuejike, Chiegwu Hyacienth Uche, Nwodo Victor Kelechi, Omojola Akintayo Daniel

    Background: Detecting subtle changes in the parotid gland size can be difficult when there are no established reference values in a specific area. This can affect patient management and delay early detection of diseases. Therefore, the objective of this study was to describe the size of the parotid gland of adult Nigerian people.Methods: This cross-sectional study included apparently healthy adults. The parotid glands were scanned in various sections using a 7.5 MHz probe after applying ultrasound gel. Each dimension was measured twice, and the mean value was calculat-ed. The 95% reference rages (mean ± 1.96 standard deviation) were described for various dimensions of the parotid glands.Results: Four hundred healthy adults participated in the survey. Their mean (standard deviation) age was 38.6 (14.6) years. The mean (95% reference range) of both parotid lengths was 4.7 (4.1 – 5.3) cm. The right and left parotid transverse sizes were 3.8 (3.4 – 4.2) and 3.7 (2.9 – 4.5) respectively. The right and left parotid depths lateral to the mandible were 0.8 (0.4 – 1.2) and 0.9 (0.3 – 1.5), parotid depths dorsal to the mandible were 2.3 (1.7 – 2.9) and 2.2 (1.8 – 2.6), and parotid volume were 20.3 (13.3 – 27.1) and 19.8 (14.3 – 25.3) cm3. No significant difference was seen between the right and left parotid glands in men and women.Conclusion: This study delineates the mean and reference range values of parotid glands among healthy adults of Nigeria which can be used for clinical decision making.

  • Level of Knowledge and Teaching of Infant and Young Child Feeding Practices among Health Workers in Delta State, South-South Nigeria

    by Chukwuemeka Chrysanthus Odo, Akintayo Daniel Omojola, Benson Laboard Etchie

    Colostrum,community health extension workers (CHEWs),infant and young child feeding (IYCF),nutrition,primary health care centers (PHCs)

  • Chest X-rays of newborns in a medical facility: variation between the entrance skin dose measurements using the indirect and direct methods for clinical dose audit

    by Akintayo Daniel Omojola, Michael Onoriode Akpochafor, Samuel Olaolu Adeneye, Isiaka Olusola Akala, Azuka Anthonio Agboje

    Purpose This study aims to determine the mean and 75th percentile entrance skin dose (ESDcal) from anteroposterior (AP) chest X-rays using machine parameters (indirect method). Also, a comparison was made between the ESDcal and already determined thermoluminescent dosimeter (TLD) measurements (ESDTLD) from a previous study from the same patients’ data. In addition, the results were compared to similar articles, where the direct and indirect methods were used in estimating ESD to newborns. Materials and methods The study determined the digital radiography (DR) X-ray machine output using a calibrated XR Multidetector (silicon photodiode). X-ray machine milliampere-seconds (mAs), peak kilovoltage (kVp), focus to detector distance (FDD) and focus to skin distance (FSD) were used from a previous study. The mean kVp and mAs were 56.63 (52–60) and 5.7 (5–6.3) and the patient thickness was 9.5 (8–11.5) cm. Results The mean ESDs of the newborn between 0 and 28 days were 0.67 ± 0.09 mGy, and the 75th percentile was 0.75 mGy. The effective dose (E) for the 40 patients was 0.19 mSv and the estimated prenatal cancer risk ranged from (5–24.7) 10−6 Sv−1. The variation between the indirect and the direct methods for assessing ESD was 39.6 (33.7–45.1)%. Conclusion The 75th percentile ESD was the highest compared to the American College of Radiology–American Association of Physicists in Medicine–Society for Pediatric Radiology (ACR–AAPM–SPR), European Commission (EC) and United Kingdom (UK) reports. Comparison of both methods for assessing ESD was within 40% as compared to other studies. Based on the above results, the indirect method can be implemented for clinical dose audit.


  • Evaluation of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques for Left Breast Post-Mastectomy Patients: Our Experience in Nigerian Sovereign Investment Authority-Lagos University Teaching Hospital Cancer Center, South-West Nigeria

    by Samuel Adeneye, Michael Akpochafor, Bolanle Adegboyega, Adewumi Alabi, Nusirat Adedewe, Adedayo Joseph, Omolara Fatiregun, Akintayo Omojola, Abe Adebayo, Esther Oluwadara

    This study aimed to evaluate the dosimetric properties of treatment plans obtained from three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy techniques (IMRT) plans for left chest wall breast cancer patients. A total of 20 patients with left-sided chest wall radiotherapy were randomly selected with the dose prescriptions: 42 Gy and 45 Gy in 15 and 18 fractions, respectively. Treatment plans were obtained using 3D-CRT and IMRT for each patient. Five to seven beams were used for IMRT, while tangential beams were used for 3D-CRT. Planning target volume, Dnear-max (D2), Dnear-min (D98), Dmean, Homogeneity and Conformity Indices (HI and CI) were obtained. Similarly, mean doses to organs at risk (OAR), V5, V10, V20, V25 were generated from the dose-volume histogram and compared. IMRT showed a significant improvement in HI compared to 3D-CRT (p<0.0001). Although there was no significant difference in sparing of the left lung between both plans for high-dose volumes (V20: 18.2 vs 30.55, p<0.0001), (V25: 11.17 vs 28.12, p<0.0001). IMRT however showed supremacy to 3D-CRT with high-dose volumes for the heart, including V20 (4.44 vs 10.29, p = 0.02), V25 (2.08 vs 8.94, p = 0.002). 3D-CRT was better than IMRT in low-dose volumes for left lung (V5: 92.23 vs 56.60, p<0.001; V10: 60.98 vs 47.20, p = 0.04) and heart (V5: 57.45 vs 30.39, p = 0.004). IMRT showed better homogeneity and sparing of high-dose volumes to OAR than 3D-CRT. On the other hand, 3D-CRT showed a reduction of low-dose volumes to OARs than IMRT.


  • Open Access

    Comparison of entrance surface air kerma measurement with MTS-N (LiF: Mg, Ti) chips with a kilovoltage X-ray source

    by Akintayo Daniel Omojola, Samuel Olaolu Adeneye, Michael Onoriode Akpochafor, Isiaka Olusola Akala, Azuka Anthonio Agboje

    Objective: Radiation detectors are key components that ensure the accuracy and performances of dosimetry equipment. The study is aimed to compare the mean entrance surface air kerma (ESAK) between a DCT-10mm ionization chamber (IC) and MTS-N (LiF: Mg, Ti) chips when both detectors are exposed to ≤ 5mGy with a 10 by 10 field size, with an X-ray source and to determine the accuracy of the Thermoluminescent (TL) chips. Also, the dose will be compared to similar studies. Materials and Methods: A functional, Digital Radiography (DR) X-ray System was used. A DCT-10mm ionization chamber (IC) and an XR Multidetector was positioned at a Source to Image Distance (SID) of 100cm on polystyrene, about 20cm thick. An X-ray spectrum generated at a Practical Peak Voltage (PPV) of 60-107kV with Half Value Layer (HVL) of 2.4-4.3mmAl and filtration > 3mmAl was used. The same setup was used for the MTS-N chips. Results: The mean doses for 1-5 mGy with the MTS-N chips were 1.07±0.07, 1.60±0.13, 2.23±0.11, 2.58±0.07 and 3.45±0.10 mGy respectively, with accuracies of 7, 20, 26, 36 and 31%. Dose accuracy at 1and 2mGy was within 25% respectively. Dose accuracies at 3, 4 and 5mGy was within >25%. The correction factor for 1-5mGy was 0.94, 1.25, 1.35, 1.55 and 1.45 respectively. Conclusion: Validation of the MTS-N chips with the reference ionization chamber to this study was within 36%. The Radiation and Nuclear Safety Authority (STUK) recommends that ESAK be within 25% for entrance surface dose. ESAK accuracy mostly increased with dose as observed in this study.

  • Open Access

    Estimation of dose and cancer risk to newborn from chest X-ray in South-South Nigeria: a call for protocol optimization

    by Akintayo Daniel Omojola, Michael Onoriode Akpochafor, Samuel Olaolu Adeneye, Isiaka Olusola Akala, Azuka Anthonio Agboje

    Background: The use of X-ray as a diagnostic tool for complication and anomaly in the neonatal patient has been helpful, but the effect of radiation on newborn stands to increase their cancer risk. This study aims to determine the mean, 50th percentile (quartile 2 (Q2)), and 75th percentile (quartile 3 (Q3)) entrance surface dose (ESD) from anteroposterior (AP) chest X-ray and to compare our findings with other relevant studies. The study used calibrated thermoluminescent dosimeters (TLDs), which was positioned on the central axis of the patient. The encapsulated TLD chips were held to the patients’ body using paper tape. The mean kilovoltage peak (kVp) and milliampere seconds (mAs) used was 56.63(52–60) and 5.7 (5–6.3). The mean background TLD counts were subtracted from the exposed TLD counts and a calibration factor was applied to determine ESD. Results: The mean ESDs of the newborn between 1 and 7, 8 and 14, 15 and 21, and 22 and 28 days were 1.09 ± 0.43, 1.15 ± 0.50, 1.19 ± 0.45, and 1.32 ± 0.47 mGy respectively. A one-way ANOVA test shows that there were no differences in the mean doses for the 4 age groups (P = 0.597). The 50th percentile for the 4 age groups was 1.07, 1.26, 1.09, and 1.29 mGy respectively, and 75th percentile were 1.41, 1.55, 1.55, and 1.69 mGy respectively. The mean effective dose (ED) in this study was 0.74 mSv, and the estimated cancer risk was 20.7 × 10−6. Conclusion: ESD was primarily affected by the film-focus distance (FFD) and the patient field size. The ESD at 75th percentile and ED in this study was higher compared to other national and international studies. The estimated cancer risk to a newborn was below the International Commission on Radiological Protection (ICRP) limit for fatal childhood cancer (2.8 × 10−2Sv−1).


  • Open Access

    Validation of a Locally Designed Computed Tomography Dose Phantom: A Comparison Study with a Standard Acrylic Phantom in South-South, Nigeria

    by Anwuli Christiana Tobi, Chukwuka Emmanuel Mokobia, Joyce Ekeme Ikubor, Akintayo Daniel Omojola

    Purpose: The aim of this study was to determine the mean volume computed tomography dose index (CTDIvol) for the standard head and body phantoms and locally designed head and body phantoms respectively. Similarly, this study determined and compared the displayed mean CTDIvol and Dose Length Product (DLP) for the above phantoms from the CT monitor. In addition, the percentage deviations of both phantoms were compared with the recommended limits from the International Atomic Energy Agency (IAEA) and the American College of Radiologists (ACR). Materials and Methods: Dose measurements were made using a standard polymethymethacrylate (PMMA) phantom for head and body as well as a locally designed phantom with four CT scanners using thermoluminescence dosimeters (TLDs). The locally designed phantoms were made using a PMMA sheet, which was bent to give the desired cylindrical shape and was made like the standard phantoms. The constructed phantom was filled with water and the TLD chips were inserted into the center and peripheries of the phantoms to obtain the absorbed doses. Results: The CTDIvol for the standard head and body phantom for center A was 66.97 and 21.85mGy and for B was 23.39 and 6.29mGy respectively. Similarly, the CTDIvol for the constructed head and body phantom for center A was 63.91 and 19.84mGy and for B was 24.67 and 6.30mGy respectively. The uncertainty between the standard and constructed head phantoms for centers A and B was 4.6 and 5.5% respectively, while that of the standard and constructed body phantoms for centers A and B was 9.2 and 0.0% respectively. The maximum percent deviation from the console CTDIvol and DLP values with the four phantoms for centers A and B was within ±20%. The mean correction factors for the head and body were 0.998 and 1.05 respectively. Conclusion: The uncertainties obtained in this study were within the IAEA and ACR recommended value of ±20%. The constructed phantom proved useful for CT dose measurements.


  • Open Access

    Determination of Calibration Factors and Uncertainties Associated with the Irradiation of MTS-N (LiF: Mg, Ti) Chips with Cesium-137 and X-ray Sources Under Low Doses for Personal Dosimetry in Diagnostic Radiology

    by Akintayo Daniel Omojola, Michael Onoriode Akpochafor, Samuel Olaolu Adeneye, Moses Adebayo Aweda

    Purpose: The purpose of this study was to compare calibration factors for deep dose equivalent Hp (10) and shallow dose equivalent Hp (0.07) between Cesium (Cs)-137 and X-ray sources when they are exposed to same dose and to determine uncertainties with MTS-N (LiF: Mg, Ti) chips when they are exposed to low dose ≤ 2mGy. Material and Methods: Thermoluminescent (TL) chips were annealed at 400oC for one hour and allowed to cool and were subjected to a temperature of 100oC for another two hours using a TLD Furnace Type LAB-01/400. They were then taken to a Secondary Standard Dosimetry Laboratory (SSDL) for irradiation using a Cs-137 source at known doses (0.2-2mGy). A RadPro Cube 400 manual TLD Reader was used to determine corresponding TL signal. The above process was replicated but with a calibrated X-ray unit as the source for calibration. Results: The calibration factors (CF) from the line graph of dose (mGy) against TL signal (count) for Cs-137 source with Hp (10) and Hp (0.07) were 3.72 x 10-6 and 5.97x10-6 mGy/count respectively. Those with X-ray source for Hp (10) and Hp (0.07) were 3.44x10-6 and 4.05x10-6 mGy/count respectively with an overall coefficient of determination (R2) = 0.99. The adjusted maximum percentage deviation between the actual and calculated dose for both sources was -2.74%. The percent (%) deviation of the mean with both sources for Hp (10) and Hp (0.07) was 3.9% and 19% respectively. Conclusion: Adjusted percent deviation from both sources were within the recommended dose limit of ±30% by the Radiological Protection Institute of Ireland (RPII) and within the International Commission on Radiological Protection (ICRP) limit respectively. Better accuracy was seen for Hp (10) with both sources compared to Hp (0.07). Calibration of the MTS-N chips using both sources was successful and can be used for personal dosimetry.


  • A Simulation Study With Electronic Dosimeter to Estimate Patient and Personnel Dose in Orthopedic Surgery

    by Akintayo Omojola, Michael Akpochafor, Samuel Adeneye

    Background: The use of mini C-arm is required in many orthopedic surgeries as an image-guided tool. Studies have shown an unnecessarily high dose to patients if exposures are not properly optimized. Also, scatter radiation to personnel may increase the risk of cancer if an appropriate protective device is not used. Objectives: This study aims to determine the patient’s dose and scatter radiation to the surgeon, anesthetist, and scrub nurse. Also, a comparison will be made with other studies on this topic. Methods: A phantom was designed to simulate a patient on the operating table to produce scatter radiation. In the same vein, a mobile mini C-arm unit was positioned with the x-ray tube beneath the head and the image receptor above the operating table. Measurements were made with a measuring tape from the central axis to the position of the surgeon, anesthetist, and scrub nurse. The Entrance Surface Dose (ESD) was determined by placing the electronic dosimeter at the surface of the phantom to estimate the patient dose. Similarly, each personnel dose/dose rate from the central axis was determined using a similar detector. Results: The total average time for most orthopedic surgeries in the studied facility was 3.3 minutes. The estimated ESD to the patient was 25.03 µSv and the scatter radiation per patient reaching the simulated anesthetist, scrub nurse, and surgeon was, 3.75, 3.59, and 7.72 µSv, respectively. The estimated dose values per year to anesthetist, scrub nurse, and surgeon were 390, 373.36, and 802 µSv, respectively. Conclusion: The personnel recommended limit dose rate was <20000 µSv/y. The technical factor used and total exposure time from this study could have affected the radiation dose. This study showed that personnel was safe even without the use of lead apron. Nevertheless, the use of an appropriate protective device should be encouraged to ensure safety.

  • Open Access

    Physio-chemical investigation and analyses of contaminants in groundwater flow. Case study - Papalanto, Ifo local government area, South - Western Nigeria, Ogun State

    by Oluwaseun Deborah Olorode, Samuel Olaolu Adeneye, Aderonke Deborah Morakinyo, Opeyemi Aliu Oyeneyin, Michael Onoriode Akpochafor, Akintayo Daniel Omojola

    Objectives: Groundwater is the primary source of drinking water for roughly, a third of the world’s population, but highly vulnerable to pollution. A thorough research was carried out to investigate the extent of groundwater contamination on four active dumpsite and a control point at Papalanto, Abeokuta area, and South-Western Nigeria. Methods: Domestic wells in the area facilitated the resources for water chemistry. A total of five groundwater samples were collected from wells located close to different dumpsite in the study area, to determine the extent of groundwater contamination. Physio-chemical analysis was carried out on the five water samples; the basic method adopted in the chemical analysis includes titrimetric method, atomic absorption spectroscopy and calometric method. Results: The results showed that water quality parameter like temperature, pH, taste, odour, total solids, sulphate, copper, iron, zinc, cadmium and chromium are in appropriate standard prescribed by WHO and NSDWQ. Other physical parameters like color, turbidity, conductivity, total suspended solids, total dissolved solid, total hardness, total alkalinity, total acidity, calcium, magnesium, chloride, nitrite, manganese, lead, nickel, nitrate, have higher values than the authorized standard value, which directly or indirectly affect the water content found in the area for drinking purpose. These features could be attributed to the possible activities of contaminants facilitated by leachate plume from the dumpsite. Conclusions: The study shows that the regolith aquifer in the area of study is highly vulnerable to pollution from the refuse dumps. From the geophysical and physio-chemical analysis carried out, the values of most parameters obtained in the water samples collected at locations close to the leachate have been confirmed to be higher than those collected at locations away from the leachate. Hence, the groundwater near the leachate is confirmed contaminated.