Simultaneous Determination of Aluminium and Iron with Hematoxylin Using Spectrophotometric and Orthogonal Signal Correction‐Partial Least Squares in Plant and Water
Authors:
- 20 November 2007
- journal article
- research article
- Published by Wiley in Annali di Chimica
- Vol. 97 (11-12) , 1181-1190
Abstract
Simple and novel spectrophotometric method is described for simultaneous determination of aluminum and iron. The method is based on the colored complexes formed by aluminum and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant at pH 5.8. All factors affecting the sensitivity were optimized and the linear dynamic range for determination of aluminum and iron was found. The simultaneous determination of aluminum and iron mixtures by using spectrophotometric methods is a difficult problem, due to spectral interferences. By multivariate calibration methods such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the unrelated information and is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 360‐620 nm range for 25 different mixtures of aluminum and iron. Calibration matrices contained 0.06‐21.00 and 0.03‐15.00 μg mL‐1 of aluminum and iron, respectively. The RMSEP for aluminum and iron with OSC and without OSC were 0.06, 0.08 and 0.24, 0.27, respectively. The proposed method has been applied to the simultaneous determination of aluminum and iron in plant and water samples.Keywords
This publication has 23 references indexed in Scilit:
- Spectrophotometric simultaneous determination of nitrophenol isomers by orthogonal signal correction and partial least squaresJournal of Hazardous Materials, 2007
- Recent Developments in Multivariate CalibrationCritical Reviews in Analytical Chemistry, 2006
- Spectrophotometric simultaneous determination of uranium and thorium using partial least squares regression and orthogonal signal correctionJournal of the Brazilian Chemical Society, 2006
- Spectrophotometric simultaneous determination of nitroaniline isomers by orthogonal signal correction?partial least squaresTalanta, 2005
- Determination of doxorubicin in human plasma by excitation–emission matrix fluorescence and multi-way analysisAnalytica Chimica Acta, 2003
- Comparative study of net analyte signal-based methods and partial least squares for the simultaneous determination of amoxycillin and clavulanic acid by stopped-flow kinetic analysisAnalytica Chimica Acta, 2002
- Improved calculation of the net analyte signal in inverse multivariate calibrationJournal of Chemometrics, 2001
- Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative informationAnalytical Chemistry, 1988
- Partial least-squares methods for spectral analyses. 2. Application to simulated and glass spectral dataAnalytical Chemistry, 1988
- Partial least-squares regression: a tutorialAnalytica Chimica Acta, 1986