Fluid Reservoir Thickness and Corneal Edema during Open‐eye Scleral Lens Wear
- 1 September 2020
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 97 (9) , 683-689
Abstract
SIGNIFICANCE: There is debate concerning corneal oxygenation during scleral lens wear due to the potential additive hypoxic effect of a lens plus a fluid reservoir. This study investigated the agreement between theoretical models and empirical measurements of scleral lens–induced corneal edema with respect to central fluid reservoir thickness. PURPOSE: The purpose of this study was to examine the effect of altering the fluid reservoir thickness on central corneal edema during short‐term open‐eye scleral lens wear and to compare these empirical measurements with predictive theoretical models. METHODS: Ten participants (age, 30 ± 4 years) with normal corneas wore highly oxygen‐permeable scleral lenses (141 Dk ×10 −11 cm 3 O 2 (cm)/[(s) (cm 2 ) (mmHg)]) on separate days with either a low (mean, 144; 95% confidence interval [CI], 127 to 160 μm), medium (mean, 487; 95% CI, 443 to 532 μm), or high (mean, 726; 95% CI, 687 to 766 μm) initial fluid reservoir thickness. Epithelial, stromal, and total corneal edema were measured using high‐resolution optical coherence tomography after 90 minutes of wear, before lens removal. Data were calculated or extracted from published theoretical models of scleral lens–induced corneal edema for comparison. RESULTS: Scleral lens–induced central corneal edema was stromal in nature and increased with increasing fluid reservoir thickness; mean total corneal edema was 0.69% (95% CI, 0.34 to 1.04%), 1.81% (95% CI, 1.22 to 2.40%), and 2.11% (95% CI, 1.58 to 2.65%) for the low, medium, and high thickness groups, respectively. No significant difference in corneal edema was observed between the medium and high fluid reservoir thickness groups ( P =. 37). “Resistance in series” oxygen modeling overestimated the corneal edema observed for fluid reservoir thickness values greater than 400 μm. CONCLUSIONS: Scleral lens–induced central corneal edema increases with increasing reservoir thickness, but plateaus at a thickness of around 600 μm, in agreement with recent theoretical modeling that incorporates factors related to corneal metabolism.Keywords
This publication has 32 references indexed in Scilit:
- Mini-scleral lenses in the visual rehabilitation of patients after penetrating keratoplasty and deep lamellar anterior keratoplastyContact Lens and Anterior Eye, 2015
- Predicting scleral GP lens entrapped tear layer oxygen tensionsContact Lens and Anterior Eye, 2015
- Oxygen Diffusion and Edema With Modern Scleral Rigid Gas Permeable Contact LensesInvestigative Ophthalmology & Visual Science, 2014
- Central Vault in Dry Eye Patients Successfully Wearing Scleral LensOptometry and Vision Science, 2013
- Predicting estimates of oxygen transmissibility for scleral lensesContact Lens and Anterior Eye, 2012
- Oxygen-deficient metabolism and corneal edemaProgress in Retinal and Eye Research, 2011
- Calculated tear oxygen tension under contact lenses offering resistance in series: Piggyback and scleral lensesContact Lens and Anterior Eye, 2006
- A comparison of the effects of rigid contact lens overall diameter and axial edge lift changes on tear pump efficiencyInternational Contact Lens Clinic, 1991
- Influence of Rigid Contact Lens Overall and Optic Zone Diameters on Tear Pump EfficiencyOptometry and Vision Science, 1990
- Hydration and Transparency of Corneal StromaArchives of Ophthalmology (1950), 1966