Online Detection of Out-of-Step Condition Using PMU-Determined System Impedances
Open Access
- 4 February 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 14807-14818
Abstract
This paper presents a robust and adaptive out-of-step (OOS) protection algorithm, using wide-area information, that can be applied on tie-lines in observable power systems. The developed algorithm is based upon real-time computation of the system impedance and makes use of the well-known power-angle characteristic. In this way, a setting-less OOS concept in real-time environment is developed, which is applicable for tie-lines in an arbitrary power system. Furthermore, the developed protection algorithm is installed on hardware and is verified by numerous tests. The performance of the new hardware implementation is compared to the traditional impedance-based OOS protection methods. The results confirm that the proposed algorithm detects OOS conditions faster and more reliably than the traditional impedance-based solutions.Keywords
Funding Information
- SA Archimedes Foundation Kristjan Jaak Scholarship (16-3.5/1470)
- Esi-Bida and ReSident Project by the Dutch Scientific Council De Nederlandse Organisatie voor Wetenschappelijk Onderzoek (647.003.004)
- Project and the Consortium Consisting of Transmission System Operator (TSO) TenneT, Distribution System Operators (DSOs) Alliander-Qirion, Stedin, Enduris, and General Electric and VSL
This publication has 27 references indexed in Scilit:
- On-line determination of transient stability status using MLPNN2017
- Dynamic State Estimation Assisted Out-of-Step Detection for Generators Using Angular DifferenceIEEE Transactions on Power Delivery, 2016
- A Novel Out-of-step Splitting Protection Based on the Wide Area InformationIEEE Transactions on Smart Grid, 2016
- On-Line Thévenin Impedance Estimation Based on PMU Data and Phase Drift CorrectionIEEE Transactions on Smart Grid, 2016
- New support vector machine‐based digital relaying scheme for discrimination between power swing and faultIET Generation, Transmission & Distribution, 2014
- Out-of-step Detection Using Energy Equilibrium Criterion in Time DomainElectric Power Components and Systems, 2009
- Out-of-step protection fundamentals and advancements2004
- Short-circuit impedance measurementIEE Proceedings - Generation, Transmission and Distribution, 2003
- An adaptive out-of-step relay [for power system protection]IEEE Transactions on Power Delivery, 1997
- Extended equal area criterion justifications, generalizations, applicationsIEEE Transactions on Power Systems, 1989