Geometric accuracy in three‐dimensional coordinates of Leksell stereotactic skull frame with wide‐bore 1.5‐T MRI compared with conventional 1.5‐T MRI
Authors:
- 15 August 2014
- journal article
- research article
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 58 (5) , 595-600
Abstract
Summary: The use of 1.5‐tesla (T) magnetic resonance (MR) imaging with a wide and simultaneously short bore enhances patient comfort compared with traditional 1.5‐T MR imaging and is becoming increasingly available in stereotactic radiosurgery treatment planning. However, the geometric accuracy seems unavoidably worse in wide‐bore MR imaging than in conventional MR imaging. We assessed the geometric distortion of the stereotactic image attached on a Leksell skull frame in conventional and wide‐bore 1.5‐T MR imaging. Two kinds of acrylic phantoms were placed on the skull frame and were scanned using computed tomography (CT) and conventional and wide‐bore 1.5‐T MR imaging. The three‐dimensional coordinates on both MR imaging were compared with those on CT. Deviations of measured coordinates at selected points (x = 50, 100, 150 mm; y = 50, 100, 150 mm) were indicated on different axial planes (z = 50, 75, 100, 125, 150 mm). The differences of coordinates were less than 1.0 mm in the entire treatable area for conventional MR imaging. With the large bore system, the differences of the coordinates were less than 1.0 mm around the center but substantially exceeded 1.0 mm in the peripheral regions. Further study is needed to increase the geometric accuracy of wide‐bore MR imaging for stereotactic radiosurgery treatment planning.Keywords
This publication has 13 references indexed in Scilit:
- Commissioning of a new wide-bore MRI scanner for radiotherapy planning of head and neck cancerBritish Journal of Radiology, 2013
- CT‐only planning for Gamma Knife radiosurgery in the treatment of trigeminal neuralgia: Methodology and outcomes from a single institutionJournal of Medical Imaging and Radiation Oncology, 2012
- Wide, Short Bore Magnetic Resonance at 1.5 TClinical Neuroradiology, 2011
- Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planningPhysics in Medicine & Biology, 2010
- A two‐step scheme for distortion rectification of magnetic resonance imagesMedical Physics, 2009
- Characterization, prediction, and correction of geometric distortion in MR imagesMedical Physics, 2007
- Stereotactic Imaging for Radiosurgery: Localization Accuracy of Magnetic Resonance Imaging and Positron Emission Tomography Compared with Computed TomographyStereotactic and Functional Neurosurgery, 2006
- Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturerPhysics in Medicine & Biology, 2006
- A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mappingPhysics in Medicine & Biology, 2005
- Quantifying MRI geometric distortion in tissueMagnetic Resonance in Medicine, 1994