Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations
Top Cited Papers
Open Access
- 1 January 2015
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 14 (1) , 1
Abstract
Routine vascular surgery operations involve stitching of disconnected human arteries with themselves or with artificial grafts (arterial anastomosis). This study aims to extend current knowledge and provide better-substantiated understanding of the mechanics of end-to-end anastomosis through the development of an analytical model governing the dynamic behavior of the anastomotic region of two initially separated arteries. The formulation accounts for the arterial axial-circumferential deformation coupling and suture-artery interaction. The proposed model captures the effects of the most important parameters, including the geometric and mechanical properties of artery and sutures, number of sutures, loading characteristics, longitudinal residual stresses, and suture pre-tensioning. Closed-form expressions are derived for the system response in terms of arterial radial displacement, anastomotic gap, suture tensile force, and embedding stress due to suture-artery contact interaction. Explicit objective functionalities are established to prevent failure at the anastomotic interface. The mathematical formulation reveals useful interrelations among the problem parameters, thus making the proposed model a valuable tool for the optimal selection of materials and improved functionality of the sutures. By virtue of their generality and directness of application, the findings of this study can ultimately form the basis for the development of vascular anastomosis guidelines pertaining to the prevention of post-surgery implications.Keywords
This publication has 32 references indexed in Scilit:
- A simple fluid–structure coupling algorithm for the study of the anastomotic mechanics of vascular graftsComputer Methods in Biomechanics and Biomedical Engineering, 2010
- Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass graftsBioMedical Engineering OnLine, 2007
- Computational modeling of vascular anastomosesBiomechanics and Modeling in Mechanobiology, 2005
- A Model of Stress-induced Geometrical Remodeling of Vessel Segments Adjacent to Stents and Artery/Graft AnastomosesJournal of Theoretical Biology, 2000
- Polypropylene suture stresses after closure of longitudinal arteriotomyJournal of Vascular Surgery, 1988
- Suture technique and para-anastomotic complianceJournal of Vascular Surgery, 1986
- The development of mechanical strength of surgically anastomosed arteries sutured with DexonJournal of Biomechanics, 1985
- Failure properties of passive human aortic tissue. II—Biaxial tension testsJournal of Biomechanics, 1983
- Compliance as a factor effecting the patency of a copolyurethane vascular graftJournal of Biomedical Materials Research, 1978
- Mechanical properties of the ascending thoracic aorta of manCardiovascular Research, 1973