Experimental Oxygen Mass Transfer Study of Micro-Perforated Diffusers
Open Access
Abstract
We studied new micro-perforated diffuser concepts for the aeration process in wastewater treatment plants and evaluated their aeration efficiency. These are micro-perforated plate diffusers with orifice diameters of 30 µm, 50 µm and 70 µm and a micro-perforated tube diffuser with an orifice diameter of 50 µm. The oxygen transfer of the diffuser concepts is tested in clean water, and it is compared with commercial aerators from the literature. The micro-perforated tube diffuser and micro-perforated plate diffusers outperform the commercial membrane diffusers by up to 44% and 20%, respectively, with regard to the oxygen transfer efficiency. The most relevant reason for the improved oxygen transfer is the fine bubble aeration with bubble sizes as small as 1.8 mm. Furthermore, the more homogenous cross-sectional bubble distribution of the micro-perforated tube diffuser has a beneficial effect on the gas mass transfer due to less bubble coalescence. However, the pressure drop of micro-perforated diffusers seems to be the limiting factor for their standard aeration efficiencies due to the size and the number of orifices. Nevertheless, this study shows the potential for better aeration efficiency through the studied conceptual micro-perforated diffusers.Keywords
Funding Information
- Landesamt für Natur, Umwelt und Verbraucherschutz Nordrhein-Westfalen (17-04.02.01-9a/2014)
- Deutsche Bundesstiftung Umwelt (AZ30799)
- Helmholtz-Zentrum Dresden-Rossendorf (CLEWATEC)
This publication has 15 references indexed in Scilit:
- Bubble generation by micro-orifices with application on activated sludge wastewater treatmentChemical Engineering and Processing - Process Intensification, 2019
- Improving aeration systems in saline water: measurement of local bubble size and volumetric mass transfer coefficient of conventional membrane diffusersWater Science & Technology, 2018
- Towards improved accuracy in modeling aeration efficiency through understanding bubble size distribution dynamicsWater Research, 2018
- Factors affecting fine bubble creation and bubble size for activated sludgeWater and Environment Journal, 2014
- Energy saving in activated sludge plants by the use of more efficient fine bubble diffusersWater and Environment Journal, 2010
- Hydrodynamics and mass transfer coefficient in three-phase air-lift reactors containing activated sludgeChemical Engineering and Processing - Process Intensification, 2006
- Measurements of local bubble size distributions from various flexible membrane diffusersChemical Engineering and Processing - Process Intensification, 2006
- Bubble column reactorsProcess Biochemistry, 2005
- MODELLING OF OXYGEN TRANSFER IN DEEP DIFFUSED-AERATION TANKS AND COMPARISON WITH FULL-SCALE PLANT DATAWater Science & Technology, 1994
- Mass transfer from very small bubbles—the optimum bubble size for aerationChemical Engineering Science, 1978