Impact of stent strut link location in proximal balloon edge dilation technique for bifurcation percutaneous coronary intervention
Authors:
Open Access
- 31 January 2024
- journal article
- research article
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (2) , 137-144
Abstract
The single-stent strategy has generally been accepted as the default approach to bifurcation percutaneous coronary intervention. We have proposed the proximal balloon edge dilation (PBED) technique to prevent stent deformation during side branch (SB) dilation. This bench study aimed to evaluate the impact of stent link location and stent design on stent deformation, obstruction by stent struts at a jailed SB ostium, and incomplete stent apposition in the proximal optimization technique (POT)-PBED procedure. A coronary bifurcation model was used. We intentionally set the absence or presence of stent link on the carina (link-free or link-connect) under videoscope observation and compared stent parameters between 3- and 2-link stents (n = 5 each, n = 20 total). In the link-free group, the SB jailing rate of 3-link stents was significantly higher than that of 2-link stents (15.5 ± 5.1% vs. 6.6 ± 1.2%, p = 0.009). In the link-connect group, the SB jailing rate of 3-link stents was significantly lower than that of 2-link stents (30.0 ± 4.5% vs. 39.0 ± 2.6%, p = 0.009). In the bifurcation segment, the rate of incomplete stent apposition was significantly lower for 3-link stents of the link-connect group than for 2-link stents of the link-connect group (3.3 ± 4.2% vs. 19.0 ± 7.8%, p = 0.009). For both stent designs, ellipticity ratio was higher for link-connect group than link-free group. Link location as well as stent cell design greatly impacted stent deformation during the POT-PBED procedure. Graphical abstractKeywords
Funding Information
- JSPS KAKENHI (20K08480)
This publication has 22 references indexed in Scilit:
- Neointimal coverage of jailed side branches in coronary bifurcation lesionsCoronary Artery Disease, 2018
- Bench testing and coronary artery bifurcations: a consensus document from the European Bifurcation ClubEuroIntervention, 2018
- The EBC TWO Study (European Bifurcation Coronary TWO)Circulation: Cardiovascular Interventions, 2016
- New implication of three-dimensional optical coherence tomography in optimising bifurcation PCIEuroIntervention, 2015
- 3D optical coherence tomography: new insights into the process of optimal rewiring of side branches during bifurcational stentingEuroIntervention, 2014
- Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-upEuropean Heart Journal - Cardiovascular Imaging, 2013
- Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent ThrombosisJACC: Cardiovascular Interventions, 2012
- Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting StentsCirculation, 2011
- Factors That Influence Measurements and Accurate Evaluation of Stent Apposition by Optical Coherence Tomography Assessment Using a Phantom ModelCirculation Journal, 2009
- Incidence, Predictors, and Outcome of Thrombosis After Successful Implantation of Drug-Eluting StentsJAMA, 2005