Teruyoshi Kume
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Teruyoshi Kume has a total of 190 co-authors. Here are the top co-authors by number of shared publications:
Yoji Neishi
Department of Cardiology Kawasaki Medical School Kurashiki Okayama Japan
29 shared publicationsShiro Uemura
Department of Cardiology, Kawasaki Medical School
20 shared publicationsTomoko Tamada
Department of Cardiology Kawasaki Medical School Kurashiki Okayama Japan
18 shared publicationsNozomi Watanabe
From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, N.W., Y.N., A.H., K.Y.) and the Division of Thoracic and Cardiovascular Surgery, Department of Surgery (K.T.), Kawasaki Medical School, Kurashiki, Japan
15 shared publicationsTakahiro Kawamoto
15 shared publicationsTerumasa Koyama
Department of Cardiology Kawasaki Medical School Kurashiki Okayama Japan
15 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Coronary Plaque Phenotypes According to Physiological Disease Severity and Pullback Pressure Gradient
Background: Coronary pressure pullback characterizes both the overall physiological severity and longitudinal distribution of coronary artery disease. However, the respective relationships of physiological disease severity and longitudinal disease distribution with local and vessel‐wide plaque phenotypes remain incompletely understood. Aims: To investigate the relationships of physiological disease severity and longitudinal disease distribution with coronary plaque characteristics assessed by optical coherence tomography (OCT). Methods: We studied 216 patients with left anterior descending coronary artery disease who underwent OCT and angiography‐based physiological assessment. Quantitative flow ratio (QFR) represented overall physiological disease severity, whereas the pullback pressure gradient (PPG) index characterized longitudinal disease distribution. Associations with local OCT characteristics and whole‐vessel burden of plaque features were assessed using regression models, with physiological indices standardized per 1 SD increase. Results: Median QFR and PPG were 0.88 [0.73–0.95] and 0.76 [0.69–0.83], respectively. Lower QFR was strongly associated with greater maximum lipid arc ( β per 1 SD increase, −39.16°; 95% CI, −52.01 to −26.31; p < 0.001). PPG was not associated with maximum lipid arc in univariable analysis ( β , −9.18°; p = 0.19). After accounting for QFR, however, higher PPG was associated with greater lipid arc index ( β , 112.26 °·mm; p = 0.012) and smaller minimum lumen area ( β , −0.42 mm 2 ; p = 0.011), with a similar association observed for maximum lipid arc ( β , 16.60°; p = 0.045). Conversely, lower PPG was associated with greater whole‐vessel counts of adverse plaque features in unadjusted analyses, but these associations were attenuated after accounting for QFR. Conclusions: At comparable physiological disease severity, a more focal physiological pattern was associated with greater local lipid concentration and lumen compromise, whereas a more diffuse pattern was associated with greater whole‐vessel counts of plaque features in unadjusted analyses. These findings suggest that physiological disease severity and longitudinal disease distribution provide complementary information on the spatial phenotype of coronary atherosclerosis.
- 10 November 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Open AccessCoronary Plaque Phenotypes According to Physiological Disease Severity and Pullback Pressure Gradient
Background: Coronary pressure pullback characterizes both the overall physiological severity and longitudinal distribution of coronary artery disease. However, the respective relationships of physiological disease severity and longitudinal disease distribution with local and vessel‐wide plaque phenotypes remain incompletely understood. Aims: To investigate the relationships of physiological disease severity and longitudinal disease distribution with coronary plaque characteristics assessed by optical coherence tomography (OCT). Methods: We studied 216 patients with left anterior descending coronary artery disease who underwent OCT and angiography‐based physiological assessment. Quantitative flow ratio (QFR) represented overall physiological disease severity, whereas the pullback pressure gradient (PPG) index characterized longitudinal disease distribution. Associations with local OCT characteristics and whole‐vessel burden of plaque features were assessed using regression models, with physiological indices standardized per 1 SD increase. Results: Median QFR and PPG were 0.88 [0.73–0.95] and 0.76 [0.69–0.83], respectively. Lower QFR was strongly associated with greater maximum lipid arc ( β per 1 SD increase, −39.16°; 95% CI, −52.01 to −26.31; p < 0.001). PPG was not associated with maximum lipid arc in univariable analysis ( β , −9.18°; p = 0.19). After accounting for QFR, however, higher PPG was associated with greater lipid arc index ( β , 112.26 °·mm; p = 0.012) and smaller minimum lumen area ( β , −0.42 mm 2 ; p = 0.011), with a similar association observed for maximum lipid arc ( β , 16.60°; p = 0.045). Conversely, lower PPG was associated with greater whole‐vessel counts of adverse plaque features in unadjusted analyses, but these associations were attenuated after accounting for QFR. Conclusions: At comparable physiological disease severity, a more focal physiological pattern was associated with greater local lipid concentration and lumen compromise, whereas a more diffuse pattern was associated with greater whole‐vessel counts of plaque features in unadjusted analyses. These findings suggest that physiological disease severity and longitudinal disease distribution provide complementary information on the spatial phenotype of coronary atherosclerosis.
- Open Access
- 5 November 2026
- Published by Japanese Circulation Society in Circulation Reports
- p. CR-26-0203
Optimization of Proximal Balloon Edge Dilation Technique for Link-Connect Type of Stent in Coronary Bifurcation Interventions
Background: Coronary bifurcation lesions pose procedural challenges due to the need to maintain side branch (SB) patency. The proximal balloon edge dilation (PBED) technique has been introduced to reduce SB jailing by enhancing stent expansion at the SB ostium. However, even when using the PBED technique, the jailing ratio at the SB remains high in the presence of a stent link on the carina immediately after main branch stent implantation (link-connect type). This bench study aimed to optimize the PBED technique in link-connect type by investigating the effects of balloon pressure (nominal vs. rated burst) and inflation frequency (single vs. triple inflations) on SB jailing, stent apposition, and stent morphology.Methods and Results: A coronary bifurcation model with a 70° bifurcation angle was used with XIENCE Skypoint stents (n=10). Optical coherence tomography and videoscope imaging were used to assess stent parameters and SB jailing. Triple inflations at rated burst pressure significantly reduced the SB jailing ratio compared to single inflation at nominal pressure (18.9% vs. 28.9%, P<0.05), without negatively impacting stent apposition or ellipticity. No significant differences were observed in stent areas across groups.Conclusions: The optimized PBED technique involving triple balloon dilation at rated burst pressure was associated with the lowest SB jailing ratio without compromising stent apposition or morphology.
- 5 November 2026
- Published by Japanese Circulation Society in Circulation Reports
- p. CR-26-0203
Open AccessOptimization of Proximal Balloon Edge Dilation Technique for Link-Connect Type of Stent in Coronary Bifurcation Interventions
Background: Coronary bifurcation lesions pose procedural challenges due to the need to maintain side branch (SB) patency. The proximal balloon edge dilation (PBED) technique has been introduced to reduce SB jailing by enhancing stent expansion at the SB ostium. However, even when using the PBED technique, the jailing ratio at the SB remains high in the presence of a stent link on the carina immediately after main branch stent implantation (link-connect type). This bench study aimed to optimize the PBED technique in link-connect type by investigating the effects of balloon pressure (nominal vs. rated burst) and inflation frequency (single vs. triple inflations) on SB jailing, stent apposition, and stent morphology.Methods and Results: A coronary bifurcation model with a 70° bifurcation angle was used with XIENCE Skypoint stents (n=10). Optical coherence tomography and videoscope imaging were used to assess stent parameters and SB jailing. Triple inflations at rated burst pressure significantly reduced the SB jailing ratio compared to single inflation at nominal pressure (18.9% vs. 28.9%, P<0.05), without negatively impacting stent apposition or ellipticity. No significant differences were observed in stent areas across groups.Conclusions: The optimized PBED technique involving triple balloon dilation at rated burst pressure was associated with the lowest SB jailing ratio without compromising stent apposition or morphology.
- Open Access
- 22 September 2025
- Published by Elsevier in International Journal of Cardiology
- Vol. 443, 133909
Correlation between angiography-based physiology and plaque characteristics and clinical outcomes in patients with coronary artery disease
- 22 September 2025
- Published by Elsevier in International Journal of Cardiology
- Vol. 443, 133909
Open AccessCorrelation between angiography-based physiology and plaque characteristics and clinical outcomes in patients with coronary artery disease
- 16 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (34) , 3181-3183
Intraplaque haemorrhage, coronary spasm, and resuscitated cardiac arrest in patients with non-obstructive coronary artery disease
Sudden cardiac arrest (SCA) represents a major public health challenge, accounting for a substantial proportion of cardiovascular deaths. Most SCAs are caused by coronary artery disease (CAD); however, the underlying pathophysiological mechanisms are not completely understood, particularly in patients without overt occlusive CAD. While thrombotic lesions from plaque rupture or erosion are commonly implicated in cardiac arrests originating from coronary arteries,1 numerous instances lack an apparent thrombotic occlusive lesion. Intraplaque haemorrhage (IPH) in coronary arteries has recently gained attention as a potential yet under-recognized factor in SCA.2 Concurrently, coronary spasm, which can induce acute myocardial ischaemia, has been identified as another potential trigger for SCA, especially in patients lacking significant occlusive CAD. This raises the possibility that coronary spasm and IPH might play a more substantial role in SCA pathogenesis than previously understood. However, clinical data exploring the prevalence and impact of both IPH and coronary spasm in patients with SCA, particularly those without occlusive lesions, remain limited. This gap in knowledge highlights the need for further investigation into these potentially critical factors in SCA pathophysiology.
- 16 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (34) , 3181-3183
Intraplaque haemorrhage, coronary spasm, and resuscitated cardiac arrest in patients with non-obstructive coronary artery disease
Sudden cardiac arrest (SCA) represents a major public health challenge, accounting for a substantial proportion of cardiovascular deaths. Most SCAs are caused by coronary artery disease (CAD); however, the underlying pathophysiological mechanisms are not completely understood, particularly in patients without overt occlusive CAD. While thrombotic lesions from plaque rupture or erosion are commonly implicated in cardiac arrests originating from coronary arteries,1 numerous instances lack an apparent thrombotic occlusive lesion. Intraplaque haemorrhage (IPH) in coronary arteries has recently gained attention as a potential yet under-recognized factor in SCA.2 Concurrently, coronary spasm, which can induce acute myocardial ischaemia, has been identified as another potential trigger for SCA, especially in patients lacking significant occlusive CAD. This raises the possibility that coronary spasm and IPH might play a more substantial role in SCA pathogenesis than previously understood. However, clinical data exploring the prevalence and impact of both IPH and coronary spasm in patients with SCA, particularly those without occlusive lesions, remain limited. This gap in knowledge highlights the need for further investigation into these potentially critical factors in SCA pathophysiology.
- Open Access
- 31 January 2024
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (2) , 137-144
Impact of stent strut link location in proximal balloon edge dilation technique for bifurcation percutaneous coronary intervention
The single-stent strategy has generally been accepted as the default approach to bifurcation percutaneous coronary intervention. We have proposed the proximal balloon edge dilation (PBED) technique to prevent stent deformation during side branch (SB) dilation. This bench study aimed to evaluate the impact of stent link location and stent design on stent deformation, obstruction by stent struts at a jailed SB ostium, and incomplete stent apposition in the proximal optimization technique (POT)-PBED procedure. A coronary bifurcation model was used. We intentionally set the absence or presence of stent link on the carina (link-free or link-connect) under videoscope observation and compared stent parameters between 3- and 2-link stents (n = 5 each, n = 20 total). In the link-free group, the SB jailing rate of 3-link stents was significantly higher than that of 2-link stents (15.5 ± 5.1% vs. 6.6 ± 1.2%, p = 0.009). In the link-connect group, the SB jailing rate of 3-link stents was significantly lower than that of 2-link stents (30.0 ± 4.5% vs. 39.0 ± 2.6%, p = 0.009). In the bifurcation segment, the rate of incomplete stent apposition was significantly lower for 3-link stents of the link-connect group than for 2-link stents of the link-connect group (3.3 ± 4.2% vs. 19.0 ± 7.8%, p = 0.009). For both stent designs, ellipticity ratio was higher for link-connect group than link-free group. Link location as well as stent cell design greatly impacted stent deformation during the POT-PBED procedure. Graphical abstract
- 31 January 2024
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 39 (2) , 137-144
Open AccessImpact of stent strut link location in proximal balloon edge dilation technique for bifurcation percutaneous coronary intervention
The single-stent strategy has generally been accepted as the default approach to bifurcation percutaneous coronary intervention. We have proposed the proximal balloon edge dilation (PBED) technique to prevent stent deformation during side branch (SB) dilation. This bench study aimed to evaluate the impact of stent link location and stent design on stent deformation, obstruction by stent struts at a jailed SB ostium, and incomplete stent apposition in the proximal optimization technique (POT)-PBED procedure. A coronary bifurcation model was used. We intentionally set the absence or presence of stent link on the carina (link-free or link-connect) under videoscope observation and compared stent parameters between 3- and 2-link stents (n = 5 each, n = 20 total). In the link-free group, the SB jailing rate of 3-link stents was significantly higher than that of 2-link stents (15.5 ± 5.1% vs. 6.6 ± 1.2%, p = 0.009). In the link-connect group, the SB jailing rate of 3-link stents was significantly lower than that of 2-link stents (30.0 ± 4.5% vs. 39.0 ± 2.6%, p = 0.009). In the bifurcation segment, the rate of incomplete stent apposition was significantly lower for 3-link stents of the link-connect group than for 2-link stents of the link-connect group (3.3 ± 4.2% vs. 19.0 ± 7.8%, p = 0.009). For both stent designs, ellipticity ratio was higher for link-connect group than link-free group. Link location as well as stent cell design greatly impacted stent deformation during the POT-PBED procedure. Graphical abstract
- Open Access
- 18 December 2023
- Published by Springer Nature in Nature Reviews Cardiology
- Vol. 21 (5) , 348
Author Correction: Optical coherence tomography in coronary atherosclerosis assessment and intervention
- 18 December 2023
- Published by Springer Nature in Nature Reviews Cardiology
- Vol. 21 (5) , 348
Open AccessAuthor Correction: Optical coherence tomography in coronary atherosclerosis assessment and intervention
- Open Access
- 22 March 2023
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 16 (8) , 997-999
Variation of the Appearance of Intraplaque Hemorrhage on Optical Coherence Tomography and Intravascular Ultrasound
- 22 March 2023
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 16 (8) , 997-999
Open AccessVariation of the Appearance of Intraplaque Hemorrhage on Optical Coherence Tomography and Intravascular Ultrasound
- 8 March 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (19) , 1766
Resuscitated sudden cardiac arrest related to intraplaque haemorrhage and coronary artery spasm
A 72-year-old man with a history of chronic kidney disease, dyslipidaemia, and hypertension felt chest tightness after walking uphill and sat down to rest. Shortly thereafter, he suddenly collapsed, and cardiopulmonary resuscitation was started by a nearby family member. The initial electrocardiogram waveform was ventricular fibrillation, which was restored to sinus rhythm with an automated external defibrillator. He was transported to our hospital. No significant electrocardiographic changes, but positive serum troponin was observed on arrival. Emergency coronary angiography was performed, revealing a moderate stenosis in the proximal left anterior descending coronary artery (Panel A) which was functionally significant (Panel B). Optical coherence tomography showed a large eccentric plaque with a confined low-intensity plaque with strong signal attenuation (Panel C) and some areas of low intensity and low attenuation (Panel D), highly suggestive of intraplaque haemorrhage (IPH) (see Supplementary data online, Video S1).1 A stent implantation was subsequently performed (Panel E). On the ninth day of hospitalization, an acetylcholine provocation test was performed for the right coronary artery and severe diffuse coronary spasm was induced (Panels F and G) accompanied by chest tightness and ST elevation on electrocardiogram, leading to a diagnosis of coronary spastic angina.
- 8 March 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (19) , 1766
Resuscitated sudden cardiac arrest related to intraplaque haemorrhage and coronary artery spasm
A 72-year-old man with a history of chronic kidney disease, dyslipidaemia, and hypertension felt chest tightness after walking uphill and sat down to rest. Shortly thereafter, he suddenly collapsed, and cardiopulmonary resuscitation was started by a nearby family member. The initial electrocardiogram waveform was ventricular fibrillation, which was restored to sinus rhythm with an automated external defibrillator. He was transported to our hospital. No significant electrocardiographic changes, but positive serum troponin was observed on arrival. Emergency coronary angiography was performed, revealing a moderate stenosis in the proximal left anterior descending coronary artery (Panel A) which was functionally significant (Panel B). Optical coherence tomography showed a large eccentric plaque with a confined low-intensity plaque with strong signal attenuation (Panel C) and some areas of low intensity and low attenuation (Panel D), highly suggestive of intraplaque haemorrhage (IPH) (see Supplementary data online, Video S1).1 A stent implantation was subsequently performed (Panel E). On the ninth day of hospitalization, an acetylcholine provocation test was performed for the right coronary artery and severe diffuse coronary spasm was induced (Panels F and G) accompanied by chest tightness and ST elevation on electrocardiogram, leading to a diagnosis of coronary spastic angina.
- 1 March 2023
- Vol. 39 (2) , 266-276
Efficacy of Optical Coherence Tomography-Guided Primary Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome
Background: Optical coherence tomography (OCT) is currently used as a guide for percutaneous coronary intervention (PCI), however its clinical benefit in comparison with intravascular ultrasound (IVUS) remains unclear in patients with acute coronary syndrome (ACS). Objectives: The purpose of this study was to evaluate the clinical efficacy of OCT-guided PCI in comparison with IVUS-guided PCI in patients with ACS.Methods: The study participants comprised 280 consecutive ACS patients who underwent primary PCI for de novo culprit lesions under OCT or IVUS guidance.Results: Compared with the IVUS-guided group, the OCT-guided group had lower Killip classification (p < 0.001) and lower creatinine level at baseline (0.80 +/- 0.37 mg/dl vs. 1.13 +/- 1.29 mg/dl, p = 0.004). Fluoroscopy time and total procedure time were significantly shorter in the OCT-guided group than in the IVUS-guided group (32 +/- 13 min vs. 41 +/- 19 min, p < 0.001, and 98 +/- 39 min vs. 127 +/- 47 min, p = 0.002, respectively). The major adverse cardiovascular event-free survival curves were similar between the OCT-and IVUS-guided groups after adjusting for clinical background using propensity score (log-rank p = 0.328).Conclusions: After adjusting for clinical background, OCT-guided PCI could provide comparable clinical outcomes to IVUS-guided PCI in patients with ACS. Shorter fluoroscopy time and total procedure time with OCT may reduce patient radiation exposure and also improve hospital workflow.
- 1 March 2023
- Vol. 39 (2) , 266-276
Efficacy of Optical Coherence Tomography-Guided Primary Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome
Background: Optical coherence tomography (OCT) is currently used as a guide for percutaneous coronary intervention (PCI), however its clinical benefit in comparison with intravascular ultrasound (IVUS) remains unclear in patients with acute coronary syndrome (ACS). Objectives: The purpose of this study was to evaluate the clinical efficacy of OCT-guided PCI in comparison with IVUS-guided PCI in patients with ACS.Methods: The study participants comprised 280 consecutive ACS patients who underwent primary PCI for de novo culprit lesions under OCT or IVUS guidance.Results: Compared with the IVUS-guided group, the OCT-guided group had lower Killip classification (p < 0.001) and lower creatinine level at baseline (0.80 +/- 0.37 mg/dl vs. 1.13 +/- 1.29 mg/dl, p = 0.004). Fluoroscopy time and total procedure time were significantly shorter in the OCT-guided group than in the IVUS-guided group (32 +/- 13 min vs. 41 +/- 19 min, p < 0.001, and 98 +/- 39 min vs. 127 +/- 47 min, p = 0.002, respectively). The major adverse cardiovascular event-free survival curves were similar between the OCT-and IVUS-guided groups after adjusting for clinical background using propensity score (log-rank p = 0.328).Conclusions: After adjusting for clinical background, OCT-guided PCI could provide comparable clinical outcomes to IVUS-guided PCI in patients with ACS. Shorter fluoroscopy time and total procedure time with OCT may reduce patient radiation exposure and also improve hospital workflow.
- 5 February 2023
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (3) , 520-527
Efficacy of a new generation intracoronary optical coherence tomography imaging system with fast pullback
Objectives: We sought to investigate whether a novel, fast‐pullback, high‐frequency optical coherence tomography (HF‐OCT) imaging system enables data acquisition with a reduced amount of contrast agents while retaining the same qualitative and quantitative lesion assessment to conventional OCT.Background: The increased amount of administered contrast agents is a major concern when performing intracoronary OCT.Methods: The present study is a single‐center, prospective, observational study including 10 patients with stable coronary artery disease. A total of 28 individual coronary arteries were assessed by both fast‐pullback HF‐OCT and by conventional OCT.Results: The contrast volume used in each OCT run for the HF‐OCT system was significantly lower than for the conventional OCT system (5.0 ± 0.0 mL vs. 7.8 ± 0.7 mL, respectively, with a mean difference of −2.84 [95% confidence interval [CI]: −3.10 to −2.58]). No significant difference was found in the median value of the clear image length between the two OCT systems (74 mm [interquartile range [IQR]; 63, 81], 74 mm [IQR; 71, 75], p = 0.89). Fast‐pullback HF‐OCT showed comparable measurements to conventional OCT, including minimum lumen area (3.27 ± 1.53 mm2 vs. 3.21 ± 1.53 mm2, p = 0.27), proximal reference area (7.03 ± 2.28 mm2 vs. 7.03 ± 2.34 mm2, p = 0.96), and distal reference area (5.93 ± 1.96 mm2 vs. 6.03 ± 2.02 mm2, p = 0.23). Qualitative OCT findings were comparable between the fast‐pullback HF‐OCT runs and conventional OCT with respect to identifying lipid‐rich plaques, calcifications, layered plaques, macrophages, and cholesterol crystals.Conclusion: With the fast pullback function of a novel HF‐OCT imaging system, we acquired OCT images using a significantly lower amount of contrast volume while retaining a comparable qualitative and quantitative lesion assessment to conventional OCT.
- 5 February 2023
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (3) , 520-527
Efficacy of a new generation intracoronary optical coherence tomography imaging system with fast pullback
Objectives: We sought to investigate whether a novel, fast‐pullback, high‐frequency optical coherence tomography (HF‐OCT) imaging system enables data acquisition with a reduced amount of contrast agents while retaining the same qualitative and quantitative lesion assessment to conventional OCT.Background: The increased amount of administered contrast agents is a major concern when performing intracoronary OCT.Methods: The present study is a single‐center, prospective, observational study including 10 patients with stable coronary artery disease. A total of 28 individual coronary arteries were assessed by both fast‐pullback HF‐OCT and by conventional OCT.Results: The contrast volume used in each OCT run for the HF‐OCT system was significantly lower than for the conventional OCT system (5.0 ± 0.0 mL vs. 7.8 ± 0.7 mL, respectively, with a mean difference of −2.84 [95% confidence interval [CI]: −3.10 to −2.58]). No significant difference was found in the median value of the clear image length between the two OCT systems (74 mm [interquartile range [IQR]; 63, 81], 74 mm [IQR; 71, 75], p = 0.89). Fast‐pullback HF‐OCT showed comparable measurements to conventional OCT, including minimum lumen area (3.27 ± 1.53 mm2 vs. 3.21 ± 1.53 mm2, p = 0.27), proximal reference area (7.03 ± 2.28 mm2 vs. 7.03 ± 2.34 mm2, p = 0.96), and distal reference area (5.93 ± 1.96 mm2 vs. 6.03 ± 2.02 mm2, p = 0.23). Qualitative OCT findings were comparable between the fast‐pullback HF‐OCT runs and conventional OCT with respect to identifying lipid‐rich plaques, calcifications, layered plaques, macrophages, and cholesterol crystals.Conclusion: With the fast pullback function of a novel HF‐OCT imaging system, we acquired OCT images using a significantly lower amount of contrast volume while retaining a comparable qualitative and quantitative lesion assessment to conventional OCT.