Impact of Mouse Model on Preclinical Dosimetry in Targeted Radionuclide Therapy
- 30 October 2009
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 97 (12) , 2076-2085
Abstract
Small animal dosimetry serves as an important link in establishing a relationship between absorbed dose and biological effect during preclinical targeted radionuclide therapy. Dosimetric approaches reported to date are based on models aiming at representing the animals used during preclinical experiments. However, anatomical variations between models may generate differences in the dosimetric results. Our goal was to assess the impact of the mouse model on the absorbed dose per cumulated activity (S-value, in gray per becquerel-seconds). Two datasets were considered. The first one was developed in our laboratory and is a voxel-based model of a 30-g female nude mouse. Images were segmented manually to identify more than 30 organs and suborgans. The second dataset originates from the DIGIMOUSE project. In that model, a 28-g normal male nude mouse was used to generate the segmented structures of nine regions in the head and 12 major organs. A software developed in our laboratory allowed us to read each three-dimensional mouse atlas slice by slice, to crop the mouse volume to remove background air voxels, and to write the geometry description as an input file for the Monte Carlo code MCNPX using "repeated structure representation." A linear interpolation scales the voxel size as a function of the total body mass. The comparison of various voxel-based mouse dosimetric models shows that even when scaled to the same total-body mass, models from different mouse breed or gender demonstrate very different organ masses, volumes, and, therefore, S-values. Computation of the S-values for preclinical studies depends strongly on the definition of the mouse model. Our computational model is a step in the direction of a more realistic description of the geometry in preclinical dosimetry.Keywords
This publication has 18 references indexed in Scilit:
- Peptide-targeted radionuclide therapy for melanomaCritical Reviews in Oncology/Hematology, 2008
- Cell Membrane is a More Sensitive Target than Cytoplasm to Dense Ionization Produced by Auger ElectronsRadiation Research, 2008
- Radioimmunotherapy as a Therapeutic Option for Non-Hodgkin’s LymphomaSeminars in Radiation Oncology, 2007
- Mouse S-Factors Based on Monte Carlo Simulations in the Anatomical Realistic Moby Phantom for Internal DosimetryCancer Biotherapy and Radiopharmaceuticals, 2007
- Monte Carlo simulations of absorbed dose in a mouse phantom from 18‐fluorine compoundsMedical Physics, 2007
- Small Animal Absorbed Radiation Dose from Serial Micro-Computed Tomography ImagingMolecular Imaging and Biology, 2007
- A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP)Physics in Medicine & Biology, 2007
- Digimouse: a 3D whole body mouse atlas from CT and cryosection dataPhysics in Medicine & Biology, 2007
- Development of a 4-D digital mouse phantom for molecular imaging researchMolecular Imaging and Biology, 2004
- The composition of body tissuesBritish Journal of Radiology, 1986