Noise Reduction Technique for Single-Color Video Plethysmography Using Singular Spectrum Analysis
- 6 November 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (6) , 1788-1795
Abstract
Recently, a contactless method for measuring a biological signal using a video camera has garnered attention. Especially, video plethysmography, a technique for obtaining a pulse wave from a video, is useful for managing the health of people on a daily basis. However, any body movement of a person subjected to the measurement leads to the generation of irregular noise in video plethysmography and reduces the accuracy of the recorded biological information, e.g., heart rate, during the measurement. Blind source separation is a popular technique for eliminating noise from the results of video plethysmography comprising different multiple-color channels. However, it is difficult to apply this technique to a single-color video such as a near-infrared video. Herein, a new method that combines singular spectrum analysis with the circular autocorrelation function is introduced to eliminate irregular noise in single-color video plethysmography. Applying the proposed method on videos collected from 39 individuals improved the estimation accuracy of instantaneous heart rate by approximately 44% over a conventional method using a linear filter. Furthermore, the proposed method also enabled more precise estimations of the heart rate than that achieved using multi-color video plethysmography.Keywords
Funding Information
- COI Stream Project
- Ministry of Education, Culture, Sports, Science and Technology
This publication has 31 references indexed in Scilit:
- Non-contact measurement of oxygen saturation with an RGB cameraBiomedical Optics Express, 2015
- A new look at the essence of the imaging photoplethysmographyScientific Reports, 2015
- Heterogeneity of Prognostic Studies of 24-Hour Blood Pressure Variability: Systematic Review and Meta-AnalysisPLOS ONE, 2015
- Signal recovery in imaging photoplethysmographyPhysiological Measurement, 2013
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- Noncontact imaging photoplethysmography to effectively access pulse rate variabilityJournal of Biomedical Optics, 2012
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Local Regulation of Microvascular Perfusion2008
- Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressureJournal of Applied Physiology, 2006
- Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular ControlScience, 1981