Makoto Yoshizawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Makoto Yoshizawa has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Norihiro Sugita
Graduate School of Engineering, Tohoku University, Sendai, Japan
2 shared publications - Akira Tanaka
Faculty of Symbolic Systems Science, Fukushima University, Fukushima, Japan.
1 shared publication K. Sunagawa
1 shared publicationK. Uemura
1 shared publication- Kenichi Abe
Department of Computer Science, College of Engineering, Nihon University, Koriyama, Fukushima-Ken, 963-8642, Japan
1 shared publication - Kenji Baheux
Graduate School of Engineering, Tohoku University, Sendai, Japan
1 shared publication
Latest Publications
- 6 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (6) , 1788-1795
Noise Reduction Technique for Single-Color Video Plethysmography Using Singular Spectrum Analysis
Recently, a contactless method for measuring a biological signal using a video camera has garnered attention. Especially, video plethysmography, a technique for obtaining a pulse wave from a video, is useful for managing the health of people on a daily basis. However, any body movement of a person subjected to the measurement leads to the generation of irregular noise in video plethysmography and reduces the accuracy of the recorded biological information, e.g., heart rate, during the measurement. Blind source separation is a popular technique for eliminating noise from the results of video plethysmography comprising different multiple-color channels. However, it is difficult to apply this technique to a single-color video such as a near-infrared video. Herein, a new method that combines singular spectrum analysis with the circular autocorrelation function is introduced to eliminate irregular noise in single-color video plethysmography. Applying the proposed method on videos collected from 39 individuals improved the estimation accuracy of instantaneous heart rate by approximately 44% over a conventional method using a linear filter. Furthermore, the proposed method also enabled more precise estimations of the heart rate than that achieved using multi-color video plethysmography.
- 6 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (6) , 1788-1795
Noise Reduction Technique for Single-Color Video Plethysmography Using Singular Spectrum Analysis
Recently, a contactless method for measuring a biological signal using a video camera has garnered attention. Especially, video plethysmography, a technique for obtaining a pulse wave from a video, is useful for managing the health of people on a daily basis. However, any body movement of a person subjected to the measurement leads to the generation of irregular noise in video plethysmography and reduces the accuracy of the recorded biological information, e.g., heart rate, during the measurement. Blind source separation is a popular technique for eliminating noise from the results of video plethysmography comprising different multiple-color channels. However, it is difficult to apply this technique to a single-color video such as a near-infrared video. Herein, a new method that combines singular spectrum analysis with the circular autocorrelation function is introduced to eliminate irregular noise in single-color video plethysmography. Applying the proposed method on videos collected from 39 individuals improved the estimation accuracy of instantaneous heart rate by approximately 44% over a conventional method using a linear filter. Furthermore, the proposed method also enabled more precise estimations of the heart rate than that achieved using multi-color video plethysmography.
- Open Access
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Evaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Open AccessEvaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- Open Access
- 19 July 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 27
Simulating hemispatial neglect with virtual reality
Hemispatial neglect is a cognitive disorder defined as a lack of attention for stimuli contra-lateral to the brain lesion. The assessment is traditionally done with basic pencil and paper tests and the rehabilitation programs are generally not well adapted. We propose a virtual reality system featuring an eye-tracking device for a better characterization of the neglect that will lead to new rehabilitation techniques.
- 19 July 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 27
Open AccessSimulating hemispatial neglect with virtual reality
Hemispatial neglect is a cognitive disorder defined as a lack of attention for stimuli contra-lateral to the brain lesion. The assessment is traditionally done with basic pencil and paper tests and the rehabilitation programs are generally not well adapted. We propose a virtual reality system featuring an eye-tracking device for a better characterization of the neglect that will lead to new rehabilitation techniques.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1648-1653
Analysis of Human Learning Process on Manual Control of Complex Systems
In this paper, a novel analysis technique is applied for investigating human operators' trial and error learning process to control a nonholonomic system, 2-link planer underactuated manipulator (2PUAM). An essential core of the technique is to use a value function of the reinforcement learning scheme for revealing how the operators can find a control strategy. It is an advantage of the proposed technique compared to the others that a transition of the value function may explain the changes of the operators' strategies during the learning process. According to the results of the analysis, the operators tended to explore an objective trajectory first, and then shift to the tracking control of the trajectory. The tracking was accompanied with acceleration to achieve the goal faster. Interestingly, the acceleration disturbs the objective trajectory due to the complex dynamics of the target, and induces another exploration to get better trajectories. The fact that this phase transition structure under unsupervised learning environment is consistent with previously reported results for a supervised case implies that the structure can be a general nature of human learning process.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1648-1653
Analysis of Human Learning Process on Manual Control of Complex Systems
In this paper, a novel analysis technique is applied for investigating human operators' trial and error learning process to control a nonholonomic system, 2-link planer underactuated manipulator (2PUAM). An essential core of the technique is to use a value function of the reinforcement learning scheme for revealing how the operators can find a control strategy. It is an advantage of the proposed technique compared to the others that a transition of the value function may explain the changes of the operators' strategies during the learning process. According to the results of the analysis, the operators tended to explore an objective trajectory first, and then shift to the tracking control of the trajectory. The tracking was accompanied with acceleration to achieve the goal faster. Interestingly, the acceleration disturbs the objective trajectory due to the complex dynamics of the target, and induces another exploration to get better trajectories. The fact that this phase transition structure under unsupervised learning environment is consistent with previously reported results for a supervised case implies that the structure can be a general nature of human learning process.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2005 (1094687X) , 3909-3912
Development of Detection Algorithm of Fatal Arrhythmia for a New Implantable Cardioverter Defibrillator
This study discusses the validity of new methods of detecting fatal arrhythmia used for ICDs. The method utilizes the steady state gain of the system from the ECG signal to the ventricular volume signal. After analyzing the data measured in a dog, it has been shown that the system can be approximated by a second order resonant system. Moreover, it has been indicated that the batch-type least squares method with the short data window shifting every time the R-wave occurs is better rather than a few versions of recursive algorithms for identifying time-varying parameters
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2005 (1094687X) , 3909-3912
Development of Detection Algorithm of Fatal Arrhythmia for a New Implantable Cardioverter Defibrillator
This study discusses the validity of new methods of detecting fatal arrhythmia used for ICDs. The method utilizes the steady state gain of the system from the ECG signal to the ventricular volume signal. After analyzing the data measured in a dog, it has been shown that the system can be approximated by a second order resonant system. Moreover, it has been indicated that the batch-type least squares method with the short data window shifting every time the R-wave occurs is better rather than a few versions of recursive algorithms for identifying time-varying parameters