Movement Control and Long-Latency Reflexes Are Reproducible Measures of Shoulder Neuromuscular Control
Open Access
- 8 April 2026
- journal article
- research article
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (2) , 150
Abstract
Background: Human physiology-based biomarkers, such as transcortical long-latency reflexes (LLRs) and movement control performance, are measurements used to evaluate human performance. We developed a method to assess human performance variables using a custom-designed visuomotor control device with the capability to examine performance accuracy and neurophysiological responses to unexpected perturbations. We assessed the internal consistency and reproducibility of this device during a shoulder tracking task including the performance accuracy and the transcortical long-latency reflexes during unexpected perturbations. Methods: 86 healthy young adults (49 females, right-handed, mean age 25.8 ± 9.5 years) were assessed for internal consistency across varying resistance and velocity conditions. We next determined test–retest reliability among 31 participants (17 females, right-handed, mean age 24.13 ± 3.8 years). We then determined the predictability of the LLRs and performance error during perturbations using the receiver operating characteristic analysis (ROC). Results: Our results supported excellent internal consistency, fair-to-good test–retest reliability for task performance accuracy, and fair-to-good transcortical LLR responses to perturbations (McDonald’s omega > 0.9; intraclass correlation coefficients (ICCs, 0.63–0.82)). Tracking accuracy, changes in movement velocity, and infraspinatus LLRs were effective predictors of perturbation conditions (receiver operating characteristics: AUC 0.72–0.90). Conclusions: These findings support that performance-based biomarkers have moderate-to-good reliability and neurophysiology-based biomarkers have fair-to-good reliability when assessing human shoulder performance among healthy adults. Studies are currently underway to determine if these measures are reproducible across other joint movements and among people with musculoskeletal and central nervous system injury.Keywords
Funding Information
- National Institutes of Health (R01HD084645)
- National Institutes of Health (R01HD082109)
This publication has 39 references indexed in Scilit:
- ROC curve analysis: a useful statistic multi-tool in the research of nephrologyInternational Urology and Nephrology, 2024
- Myotonic dystrophy type 1 alters muscle twitch properties, spinal reflexes, and perturbation‐induced trans‐cortical reflexesMuscle & Nerve, 2019
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Acceleration dependence and task-specific modulation of short- and medium-latency reflexes in the ankle extensorsPhysiological Reports, 2013
- Bilateral impairments in task-dependent modulation of the long-latency stretch reflex following strokeClinical Neurophysiology, 2013
- Optimal feedback control and the long-latency stretch responseExperimental Brain Research, 2012
- Electrophysiological deterioration over time in patients with Huntington's diseaseMovement Disorders, 2006
- Fusimotor discharge patterns during rhythmic movementsTrends in Neurosciences, 1993
- Measuring change over time: Assessing the usefulness of evaluative instrumentsJournal of Chronic Diseases, 1987
- Coefficient Alpha and the Internal Structure of TestsPsychometrika, 1951