Clayton Rosinski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Clayton Rosinski has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Nahom Teferi
Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
2 shared publications - Patrick W. Hitchon
Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, USA
2 shared publications - Satoshi Yamaguchi
Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
2 shared publications Ajmain Chowdhury
Department of Radiology, The University of Minnesota, Minneapolis, MN, USA
1 shared publicationAnthony J. Marincovich
Department of Neurosurgery, The University of Iowa, Iowa City, Iowa, USA
1 shared publicationAnthony Marincovich
Department of Neurosurgery, The University of Iowa, Iowa City, IA, USA
1 shared publication
Latest Publications
- Open Access
- 17 July 2026
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 270, 109579
Comparison of survival, neurological, and radiographic outcomes between corpectomy and instrumented separation surgery for spinal metastatic disease: A single institutional experience
- 17 July 2026
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 270, 109579
Open AccessComparison of survival, neurological, and radiographic outcomes between corpectomy and instrumented separation surgery for spinal metastatic disease: A single institutional experience
- Open Access
- 8 April 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (2) , 150
Movement Control and Long-Latency Reflexes Are Reproducible Measures of Shoulder Neuromuscular Control
Background: Human physiology-based biomarkers, such as transcortical long-latency reflexes (LLRs) and movement control performance, are measurements used to evaluate human performance. We developed a method to assess human performance variables using a custom-designed visuomotor control device with the capability to examine performance accuracy and neurophysiological responses to unexpected perturbations. We assessed the internal consistency and reproducibility of this device during a shoulder tracking task including the performance accuracy and the transcortical long-latency reflexes during unexpected perturbations. Methods: 86 healthy young adults (49 females, right-handed, mean age 25.8 ± 9.5 years) were assessed for internal consistency across varying resistance and velocity conditions. We next determined test–retest reliability among 31 participants (17 females, right-handed, mean age 24.13 ± 3.8 years). We then determined the predictability of the LLRs and performance error during perturbations using the receiver operating characteristic analysis (ROC). Results: Our results supported excellent internal consistency, fair-to-good test–retest reliability for task performance accuracy, and fair-to-good transcortical LLR responses to perturbations (McDonald’s omega > 0.9; intraclass correlation coefficients (ICCs, 0.63–0.82)). Tracking accuracy, changes in movement velocity, and infraspinatus LLRs were effective predictors of perturbation conditions (receiver operating characteristics: AUC 0.72–0.90). Conclusions: These findings support that performance-based biomarkers have moderate-to-good reliability and neurophysiology-based biomarkers have fair-to-good reliability when assessing human shoulder performance among healthy adults. Studies are currently underway to determine if these measures are reproducible across other joint movements and among people with musculoskeletal and central nervous system injury.
- 8 April 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (2) , 150
Open AccessMovement Control and Long-Latency Reflexes Are Reproducible Measures of Shoulder Neuromuscular Control
Background: Human physiology-based biomarkers, such as transcortical long-latency reflexes (LLRs) and movement control performance, are measurements used to evaluate human performance. We developed a method to assess human performance variables using a custom-designed visuomotor control device with the capability to examine performance accuracy and neurophysiological responses to unexpected perturbations. We assessed the internal consistency and reproducibility of this device during a shoulder tracking task including the performance accuracy and the transcortical long-latency reflexes during unexpected perturbations. Methods: 86 healthy young adults (49 females, right-handed, mean age 25.8 ± 9.5 years) were assessed for internal consistency across varying resistance and velocity conditions. We next determined test–retest reliability among 31 participants (17 females, right-handed, mean age 24.13 ± 3.8 years). We then determined the predictability of the LLRs and performance error during perturbations using the receiver operating characteristic analysis (ROC). Results: Our results supported excellent internal consistency, fair-to-good test–retest reliability for task performance accuracy, and fair-to-good transcortical LLR responses to perturbations (McDonald’s omega > 0.9; intraclass correlation coefficients (ICCs, 0.63–0.82)). Tracking accuracy, changes in movement velocity, and infraspinatus LLRs were effective predictors of perturbation conditions (receiver operating characteristics: AUC 0.72–0.90). Conclusions: These findings support that performance-based biomarkers have moderate-to-good reliability and neurophysiology-based biomarkers have fair-to-good reliability when assessing human shoulder performance among healthy adults. Studies are currently underway to determine if these measures are reproducible across other joint movements and among people with musculoskeletal and central nervous system injury.
- 29 December 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (5) , 828-835
Biomechanical Comparison of Transforaminal Interbody Fusion Implants: Static vs Expandable Cages and Unilateral Versus Bilateral Cages
BACKGROUND AND OBJECTIVES: To assess differences in biomechanical stability provided by posterior or transforaminal lumbar interbody instrumentation with expandable relative to static implants and unilateral or bilateral implants. METHODS: Nine human cadaveric lumbosacral spine specimens were subjected to motion testing before instrumentation and after single-level posterior decompression and interbody instrumentation at L3-4 with randomized order of single and bilateral static and expandable interbody implants. Measurements of disk height were also performed on the intact spine and with different implant paradigms. Changes in motion at each lumbar segment, comparison of implant paradigms, and changes in disk height at the instrumented level were statistically compared using linear mixed-effects models. RESULTS: Instrumentation resulted in a significant reduction in flexion, extension, axial rotation, and lateral bending at L3-4 for all interbody implant paradigms. Bilateral expandable cages resulted in a significantly greater reduction in lateral bending relative to single static implants and neared significance compared with bilateral static and unilateral expandable implants. Disk height increased with all implants, and bilateral expandable cages significantly increased height relative to unilateral and bilateral static cages. CONCLUSION: Bilateral expandable implants confer greater stability with regard to lateral bending forces compared with unilateral expandable, unilateral static, and bilateral static cages with posterior interbody instrumentation. In addition, bilateral expandable implants confer greater ability to increase disk space height compared with static cages. Therefore, the added cost of bilateral expandable cages may be warranted in the setting of significant coronal imbalance or very collapsed disk spaces.
- 29 December 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (5) , 828-835
Biomechanical Comparison of Transforaminal Interbody Fusion Implants: Static vs Expandable Cages and Unilateral Versus Bilateral Cages
BACKGROUND AND OBJECTIVES: To assess differences in biomechanical stability provided by posterior or transforaminal lumbar interbody instrumentation with expandable relative to static implants and unilateral or bilateral implants. METHODS: Nine human cadaveric lumbosacral spine specimens were subjected to motion testing before instrumentation and after single-level posterior decompression and interbody instrumentation at L3-4 with randomized order of single and bilateral static and expandable interbody implants. Measurements of disk height were also performed on the intact spine and with different implant paradigms. Changes in motion at each lumbar segment, comparison of implant paradigms, and changes in disk height at the instrumented level were statistically compared using linear mixed-effects models. RESULTS: Instrumentation resulted in a significant reduction in flexion, extension, axial rotation, and lateral bending at L3-4 for all interbody implant paradigms. Bilateral expandable cages resulted in a significantly greater reduction in lateral bending relative to single static implants and neared significance compared with bilateral static and unilateral expandable implants. Disk height increased with all implants, and bilateral expandable cages significantly increased height relative to unilateral and bilateral static cages. CONCLUSION: Bilateral expandable implants confer greater stability with regard to lateral bending forces compared with unilateral expandable, unilateral static, and bilateral static cages with posterior interbody instrumentation. In addition, bilateral expandable implants confer greater ability to increase disk space height compared with static cages. Therefore, the added cost of bilateral expandable cages may be warranted in the setting of significant coronal imbalance or very collapsed disk spaces.
- 30 September 2025
- Published by SAGE Publications in Interventional Neuroradiology
Catheter-assisted sealing technique for spontaneous cerebrospinal fluid leaks: A novel neurointerventional treatment of spontaneous cerebrospinal fluid leak beyond cerebrospinal fluid-venous fistula
Background: Spontaneous intracranial hypotension (SIH) is a severe condition caused by cerebrospinal fluid (CSF) leaks, leading to headaches and neurological impairments. Traditional epidural blood patch treatment is often ineffective, especially in refractory cases without a source leak identified. This study introduces and evaluates the Catheter-Assisted Sealing Technique (CAST), a novel neurointerventional approach for refractory SIH. CAST involves targeted or diffuse delivery of fibrin glue into the epidural space to repair CSF leaks. Methods: A retrospective case series of ten patients with refractory SIH underwent CAST using a fluoroscopy-guided epidural catheter approach. Clinical symptom resolution and follow-up MRI findings were assessed. Results: Nine of 10 patients achieved complete headache resolution and associated symptom relief. One patient experienced significant improvement without complete relief. Follow-up MRI showed resolution of pachymeningeal enhancement in all patients. One patient required repeat procedures for recurrent symptoms. No neurological injury or spinal cord compression occurred, with the only complication being transient femoral nerve palsy due to positioning that resolved within four months. Conclusion: CAST is a promising, minimally invasive alternative for refractory SIH. It enables targeted or diffuse fibrin sealant application, providing a seemingly effective leak closure even in cases of occult or multifocal leaks. Early results show high success and safety rates, but larger cohorts and extended follow-up are needed to validate it as a standard treatment.
- 30 September 2025
- Published by SAGE Publications in Interventional Neuroradiology
Catheter-assisted sealing technique for spontaneous cerebrospinal fluid leaks: A novel neurointerventional treatment of spontaneous cerebrospinal fluid leak beyond cerebrospinal fluid-venous fistula
Background: Spontaneous intracranial hypotension (SIH) is a severe condition caused by cerebrospinal fluid (CSF) leaks, leading to headaches and neurological impairments. Traditional epidural blood patch treatment is often ineffective, especially in refractory cases without a source leak identified. This study introduces and evaluates the Catheter-Assisted Sealing Technique (CAST), a novel neurointerventional approach for refractory SIH. CAST involves targeted or diffuse delivery of fibrin glue into the epidural space to repair CSF leaks. Methods: A retrospective case series of ten patients with refractory SIH underwent CAST using a fluoroscopy-guided epidural catheter approach. Clinical symptom resolution and follow-up MRI findings were assessed. Results: Nine of 10 patients achieved complete headache resolution and associated symptom relief. One patient experienced significant improvement without complete relief. Follow-up MRI showed resolution of pachymeningeal enhancement in all patients. One patient required repeat procedures for recurrent symptoms. No neurological injury or spinal cord compression occurred, with the only complication being transient femoral nerve palsy due to positioning that resolved within four months. Conclusion: CAST is a promising, minimally invasive alternative for refractory SIH. It enables targeted or diffuse fibrin sealant application, providing a seemingly effective leak closure even in cases of occult or multifocal leaks. Early results show high success and safety rates, but larger cohorts and extended follow-up are needed to validate it as a standard treatment.
- Open Access
- 28 April 2025
- Published by Elsevier in World Neurosurgery
- Vol. 199, 124024
Surgical Management of Unstable Atlas Fractures: A Single Institutional Retrospective Review with Comparison of Occipitocervical and Atlantoaxial Fusion Outcomes
- 28 April 2025
- Published by Elsevier in World Neurosurgery
- Vol. 199, 124024
Open AccessSurgical Management of Unstable Atlas Fractures: A Single Institutional Retrospective Review with Comparison of Occipitocervical and Atlantoaxial Fusion Outcomes