Dosimetric effect of internal error correction on pubic bones in image-guided passive scattering proton therapy for prostate cancer
Open Access
- 6 October 2025
- journal article
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 66 (6) , 682-688
Abstract
Image-guided passive scattering proton therapy (PSPT) has been widely adopted in Japan and worldwide, with substantial long-term clinical data supporting its efficacy in treating prostate cancer. However, as hypofractionated protocols become increasingly common, the impact of internal anatomical shifts on surrounding organs at risk (OARs) warrants renewed attention. The pubic bones, situated near the prostate, are often exposed to unintended high doses, especially during internal error correction based on fiducial marker alignment. This study retrospectively analyzed 30 patients with localized prostate cancer treated with PSPT using lateral opposed fields. Simulated isocenter shifts were applied anteriorly and inferiorly in 2-mm increments up to 10 mm to assess dose changes to the pubic bones. Dose-volume histogram metrics including V80%, V90% and V95% were evaluated. Pubic bones dose increased in both shift directions, with a more pronounced effect for anterior shifts, with a 10-mm anterior shift increasing V80% by 14.2 cc on average—2.4 times greater than inferior shifts. Dose elevation correlated strongly with the anatomical proximity between the clinical target volume and pubic bones (r > 0.66, P < 0.001). These results suggest that anterior correction in PSPT can cause substantial dose escalation to the pubic bones, potentially increasing the risk of insufficiency fractures. As extreme hypofractionation becomes more common, careful evaluation of pubic bones dose should be incorporated into treatment planning, alongside traditional OARs such as the rectum and bladder. Early replanning should be considered when persistent anterior displacement is observed to maintain patient safety and quality of life.Keywords
This publication has 36 references indexed in Scilit:
- Proton therapy toxicity outcomes for localized prostate cancer: Long-term results at a comprehensive cancer centerClinical and Translational Radiation Oncology, 2024
- Pelvic insufficiency fractures after intensity modulated radiation therapy combined with chemotherapy for cervix carcinoma: Incidence and impact of bone mineral densityClinical and Translational Radiation Oncology, 2023
- Vertebral compression fracture after stereotactic ablative radiotherapy in patients with oligometastatic bone lesions from hepatocellular carcinomaClinical and Translational Radiation Oncology, 2023
- Pelvic Insufficiency Fractures and Bone Pain after Radiation Therapy for Anal Cancer: Relation to Pelvic Bone Dose-Volume ParametersAdvances in Radiation Oncology, 2022
- Acute toxicity and patient‐reported symptom score after conventional versus moderately hypofractionated proton therapy for prostate cancerJournal of Medical Radiation Sciences, 2021
- Long-Term Risk of Hip Complications After Radiation Therapy for Prostate Cancer: A Dose-Response StudyAdvances in Radiation Oncology, 2021
- Patient-specific quality assurance for proton depth dose distribution using a multi-layer ionization chamber in a single-ring wobbling methodRadiological Physics and Technology, 2019
- Pelvic Complications After Prostate Cancer Radiation Therapy and Their Management: An International Collaborative Narrative ReviewEuropean Urology, 2019
- Long‐term outcomes of proton therapy for prostate cancer in Japan: a multi‐institutional survey of the Japanese Radiation Oncology Study GroupCancer Medicine, 2018
- Three‐dimensional external beam radiotherapy for prostate cancer increases the risk of hip fractureCancer, 2011