Yuki Narita
Research Subjects
Yuki Narita has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Takahiro Kato
Department of Radiological Sciences School of Health Sciences Fukushima Medical University Fukushima Fukushima Japan
10 shared publications Masao Murakami
Department of Radiation Oncology Southern Tohoku Proton Therapy Center Koriyama Fukushima Japan
6 shared publications- Ryohei Kato
Department of Radiation Physics and Technology Southern Tohoku BNCT Research Center Koriyama Fukushima Japan
6 shared publications - Shinya Komori
Department of Radiation Physics and Technology Southern Tohoku BNCT Research Center Koriyama Fukushima Japan
6 shared publications Sho Oyama
Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center , 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052
6 shared publicationsKimihiro Takemasa
Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center , 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052
4 shared publications
Latest Publications
- Open Access
Laryngeal Preservation with Boron Neutron Capture Therapy for Metachronous Second Primary Head and Neck Cancer in the Pharyngolaryngeal Region Within a Previously Irradiated Field
Background/Objectives: The occurrence of metachronous second primary head and neck cancer within a previously irradiated field presents a challenging clinical problem because reirradiation can cause severe toxicities. Boron neutron capture therapy (BNCT) may offer a curative treatment option for such tumors while minimizing the risk of severe toxicity. This study aimed to evaluate the feasibility of laryngeal preservation using BNCT for these tumors. Methods: Patients with metachronous second primary cancer in the pharyngeal or laryngeal region within a previously irradiated field who received BNCT between June 2020 and January 2022 were retrospectively included. Overall survival, laryngeal preservation, and local control were estimated using the Kaplan–Meier method. Results: All 11 patients achieved a complete response. The follow-up duration for surviving patients exceeded 4 years. The 4-year overall survival, laryngeal preservation, and local control rates were 81.8%, 80.0%, and 70.0%, respectively. No late toxicities of grade 3 or higher were observed. Among the three patients with local recurrence, two underwent salvage surgery (in one case, the patient underwent surgery after receiving BNCT once more). Local control was achieved in both patients without serious toxicities. Conclusions: BNCT for patients with metachronous second primary head and neck cancer achieved a high response rate and a high rate of laryngeal function preservation, with toxicity remaining within acceptable limits. Moreover, salvage surgery was feasible after BNCT. These findings suggest that BNCT may serve as a larynx-sparing treatment option for metachronous second primary head and neck cancer arising within a previously irradiated field.
Open AccessLaryngeal Preservation with Boron Neutron Capture Therapy for Metachronous Second Primary Head and Neck Cancer in the Pharyngolaryngeal Region Within a Previously Irradiated Field
Background/Objectives: The occurrence of metachronous second primary head and neck cancer within a previously irradiated field presents a challenging clinical problem because reirradiation can cause severe toxicities. Boron neutron capture therapy (BNCT) may offer a curative treatment option for such tumors while minimizing the risk of severe toxicity. This study aimed to evaluate the feasibility of laryngeal preservation using BNCT for these tumors. Methods: Patients with metachronous second primary cancer in the pharyngeal or laryngeal region within a previously irradiated field who received BNCT between June 2020 and January 2022 were retrospectively included. Overall survival, laryngeal preservation, and local control were estimated using the Kaplan–Meier method. Results: All 11 patients achieved a complete response. The follow-up duration for surviving patients exceeded 4 years. The 4-year overall survival, laryngeal preservation, and local control rates were 81.8%, 80.0%, and 70.0%, respectively. No late toxicities of grade 3 or higher were observed. Among the three patients with local recurrence, two underwent salvage surgery (in one case, the patient underwent surgery after receiving BNCT once more). Local control was achieved in both patients without serious toxicities. Conclusions: BNCT for patients with metachronous second primary head and neck cancer achieved a high response rate and a high rate of laryngeal function preservation, with toxicity remaining within acceptable limits. Moreover, salvage surgery was feasible after BNCT. These findings suggest that BNCT may serve as a larynx-sparing treatment option for metachronous second primary head and neck cancer arising within a previously irradiated field.
- Open Access
- 14 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Comparative assessment of respiratory‐induced tumor motion using fluoroscopy and four‐dimensional CT of solitary pulmonary lesions
Background: Four‐dimensional computed tomography (4DCT) is widely used to quantify respiratory‐induced tumor motion in thoracic radiotherapy. However, 4DCT captures discretized respiratory phases and assumes stable breathing, potentially introducing reconstruction‐related uncertainties. Fluoroscopy enables real‐time observation across multiple breathing cycles, yet direct large‐scale comparisons between fluoroscopy‐ and 4DCT‐derived motion measurements remain scarce. Purpose: To directly compare respiratory‐induced tumor motion measured by fluoroscopy and 4DCT in patients with solitary pulmonary lesions undergoing proton therapy planning under free breathing without abdominal compression. Methods: This retrospective study included 191 patients with solitary pulmonary lesions who underwent sequential fluoroscopy and 4DCT under free‐breathing conditions as part of proton therapy planning. Tumor motion was evaluated in the craniocaudal direction and stratified by lung lobe. Furthermore, diaphragmatic motion was analyzed in 131 cases. Spearman's rank correlation coefficient was used to assess correlations between motions measured by the two modalities. Measurement differences were defined as ΔD (4DCT minus fluoroscopy) and analyzed according to fluoroscopy‐measured respiratory displacement. For subgroup analyses, cases were categorized into < 5 mm, ≥ 5 to ≤ 10 mm, and > 10 mm motion groups based on fluoroscopy‐measured respiratory displacement. For Bland–Altman analyses, motion magnitude was defined as the mean of the fluoroscopy‐ and 4DCT‐derived respiratory displacement measurements, and intermodality agreement was assessed within each motion category. Results: The correlation coefficients for tumor motion in the upper‐, middle‐, and lower‐lobes were 0.61 ( p < 0.01), 0.76 ( p < 0.01), and 0.55 ( p < 0.01), respectively. The corresponding correlation coefficients for diaphragmatic motion were lower: 0.40 ( p < 0.01) on the left and 0.38 ( p < 0.01) on the right. The median |ΔD| values (interquartile range) were 1.3 mm (0.7–1.9 mm), 2.4 mm (1.0–4.1 mm), and 4.7 mm (2.6–6.8 mm) for the < 5 mm, ≥ 5 to ≤ 10 mm, and > 10 mm groups, respectively. Overall, the mean difference between 4DCT and fluoroscopy was small (−0.2 mm; 95% confidence interval, −0.9 to 0.6 mm), with 95% limits of agreement of −10.2 to 9.9 mm. The limits of agreement widened with increasing respiratory motion. Conclusions: In this single‐institution study of patients undergoing proton therapy planning, respiratory motion measurements derived from fluoroscopy and 4DCT showed larger absolute differences for lower‐lobe tumors (median |ΔD| = 4.20 mm) than for upper‐ and middle‐lobe tumors (1.70 and 1.90 mm, respectively). These findings indicate that respiratory motion estimated by 4DCT alone should be interpreted with caution in such cases. When feasible and when the lesion is fluoroscopically visible, fluoroscopic assessment may serve as a useful consistency check to complement 4DCT‐based motion evaluation.
- 14 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessComparative assessment of respiratory‐induced tumor motion using fluoroscopy and four‐dimensional CT of solitary pulmonary lesions
Background: Four‐dimensional computed tomography (4DCT) is widely used to quantify respiratory‐induced tumor motion in thoracic radiotherapy. However, 4DCT captures discretized respiratory phases and assumes stable breathing, potentially introducing reconstruction‐related uncertainties. Fluoroscopy enables real‐time observation across multiple breathing cycles, yet direct large‐scale comparisons between fluoroscopy‐ and 4DCT‐derived motion measurements remain scarce. Purpose: To directly compare respiratory‐induced tumor motion measured by fluoroscopy and 4DCT in patients with solitary pulmonary lesions undergoing proton therapy planning under free breathing without abdominal compression. Methods: This retrospective study included 191 patients with solitary pulmonary lesions who underwent sequential fluoroscopy and 4DCT under free‐breathing conditions as part of proton therapy planning. Tumor motion was evaluated in the craniocaudal direction and stratified by lung lobe. Furthermore, diaphragmatic motion was analyzed in 131 cases. Spearman's rank correlation coefficient was used to assess correlations between motions measured by the two modalities. Measurement differences were defined as ΔD (4DCT minus fluoroscopy) and analyzed according to fluoroscopy‐measured respiratory displacement. For subgroup analyses, cases were categorized into < 5 mm, ≥ 5 to ≤ 10 mm, and > 10 mm motion groups based on fluoroscopy‐measured respiratory displacement. For Bland–Altman analyses, motion magnitude was defined as the mean of the fluoroscopy‐ and 4DCT‐derived respiratory displacement measurements, and intermodality agreement was assessed within each motion category. Results: The correlation coefficients for tumor motion in the upper‐, middle‐, and lower‐lobes were 0.61 ( p < 0.01), 0.76 ( p < 0.01), and 0.55 ( p < 0.01), respectively. The corresponding correlation coefficients for diaphragmatic motion were lower: 0.40 ( p < 0.01) on the left and 0.38 ( p < 0.01) on the right. The median |ΔD| values (interquartile range) were 1.3 mm (0.7–1.9 mm), 2.4 mm (1.0–4.1 mm), and 4.7 mm (2.6–6.8 mm) for the < 5 mm, ≥ 5 to ≤ 10 mm, and > 10 mm groups, respectively. Overall, the mean difference between 4DCT and fluoroscopy was small (−0.2 mm; 95% confidence interval, −0.9 to 0.6 mm), with 95% limits of agreement of −10.2 to 9.9 mm. The limits of agreement widened with increasing respiratory motion. Conclusions: In this single‐institution study of patients undergoing proton therapy planning, respiratory motion measurements derived from fluoroscopy and 4DCT showed larger absolute differences for lower‐lobe tumors (median |ΔD| = 4.20 mm) than for upper‐ and middle‐lobe tumors (1.70 and 1.90 mm, respectively). These findings indicate that respiratory motion estimated by 4DCT alone should be interpreted with caution in such cases. When feasible and when the lesion is fluoroscopically visible, fluoroscopic assessment may serve as a useful consistency check to complement 4DCT‐based motion evaluation.
- 20 October 2026
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 51 (12) , 1123-1124
Five-Year Persistent 18F-FAPI-74 Uptake in Radiation-induced Hepatic Fibrosis Following Proton Beam Therapy for Hepatocellular Carcinoma
A 79-year-old man underwent proton beam therapy (PBT) for hepatocellular carcinoma. During follow–up, MRI demonstrated stable T2-weighted hyperintensity in the irradiated region without interval enlargement or mass formation. Five years after PBT, a new hepatocellular carcinoma developed elsewhere in the liver. 18 F–FDG PET showed no apparent abnormal uptake in the irradiated region, whereas 18 F-fibroblast activation protein inhibitor–74 PET demonstrated persistent uptake. These findings may reflect chronic radiation–induced fibroinflammatory changes and suggest that fibroblast activation protein inhibitor–PET can visualize such changes even years after PBT.
- 20 October 2026
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 51 (12) , 1123-1124
Five-Year Persistent 18F-FAPI-74 Uptake in Radiation-induced Hepatic Fibrosis Following Proton Beam Therapy for Hepatocellular Carcinoma
A 79-year-old man underwent proton beam therapy (PBT) for hepatocellular carcinoma. During follow–up, MRI demonstrated stable T2-weighted hyperintensity in the irradiated region without interval enlargement or mass formation. Five years after PBT, a new hepatocellular carcinoma developed elsewhere in the liver. 18 F–FDG PET showed no apparent abnormal uptake in the irradiated region, whereas 18 F-fibroblast activation protein inhibitor–74 PET demonstrated persistent uptake. These findings may reflect chronic radiation–induced fibroinflammatory changes and suggest that fibroblast activation protein inhibitor–PET can visualize such changes even years after PBT.
- Open Access
- 4 June 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (4) , 626-633
A model-based selection of oral cancer patient for passive scattering proton beam therapy
Background and purpose: To identify patients with oral cancer (OC) who benefit from proton therapy versus photon therapy using a model-based approach (MBA) to reduce late adverse events. Material/Methods: Passive scattering proton beam therapy (PSPT) and volumetric modulated arc therapy (VMAT) plans were established for 40 patients with OC, consisting of a dose of 70 Gy (relative biological effectiveness) in 35 fractions. At least 95% of the planning target volume received 95% of the prescribed dose, and the dose to the organs at risk was restricted to be as low as possible. Normal tissue complication probability (NTCP) was used to estimate the risk of late adverse events, including dysgeusia, xerostomia and osteoradionecrosis of the mandible. Patients who were considered as candidates for PSPT were selected if the NTCP difference between both plans (ΔNTCP) exceeded the threshold defined in the Dutch national indication protocol. Results: PSPT reduced the doses to the spinal cord, pharynx, oral cavity and contralateral salivary glands compared with VMAT. PSPT was also superior for the risk evaluation of each late adverse event calculated by incorporating dose metrics and patient baseline risk factors. For the MBA using ΔNTCP and the thresholds, PSPT was indicated in 24 of the 40 cases, and the remaining 16 cases were considered to be equivalent to VMAT. Conclusion: MBA was used to select OC cases that were candidates for PSPT. Compared with VMAT, the risk of expected late adverse events was significantly reduced with PSPT, and 60% of patients were considered eligible for PSPT.
- 4 June 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (4) , 626-633
Open AccessA model-based selection of oral cancer patient for passive scattering proton beam therapy
Background and purpose: To identify patients with oral cancer (OC) who benefit from proton therapy versus photon therapy using a model-based approach (MBA) to reduce late adverse events. Material/Methods: Passive scattering proton beam therapy (PSPT) and volumetric modulated arc therapy (VMAT) plans were established for 40 patients with OC, consisting of a dose of 70 Gy (relative biological effectiveness) in 35 fractions. At least 95% of the planning target volume received 95% of the prescribed dose, and the dose to the organs at risk was restricted to be as low as possible. Normal tissue complication probability (NTCP) was used to estimate the risk of late adverse events, including dysgeusia, xerostomia and osteoradionecrosis of the mandible. Patients who were considered as candidates for PSPT were selected if the NTCP difference between both plans (ΔNTCP) exceeded the threshold defined in the Dutch national indication protocol. Results: PSPT reduced the doses to the spinal cord, pharynx, oral cavity and contralateral salivary glands compared with VMAT. PSPT was also superior for the risk evaluation of each late adverse event calculated by incorporating dose metrics and patient baseline risk factors. For the MBA using ΔNTCP and the thresholds, PSPT was indicated in 24 of the 40 cases, and the remaining 16 cases were considered to be equivalent to VMAT. Conclusion: MBA was used to select OC cases that were candidates for PSPT. Compared with VMAT, the risk of expected late adverse events was significantly reduced with PSPT, and 60% of patients were considered eligible for PSPT.
- Open Access
- 6 May 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (3) , 369-383
Deep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions
In proton beam therapy (PBT) for hepatocellular carcinoma (HCC), deep learning (DL)-based dose prediction offers clinical value by providing immediate reference dose distributions as a guideline tool for treatment planners and enabling virtual PBT dose assessment at institutions lacking PBT facilities to support clinical decision-making. This study proposes a dose gradient-aware DL training approach and a beam arrangement-free framework that predicts dose distributions from computed tomography (CT) images and target/organs-at-risk structures without requiring beam arrangement inputs. Using data from 172 HCC patients, we systematically compared 20 DL models combining five architectures with four loss functions, including a novel dose gradient-aware loss capturing PBT-specific dose distribution characteristics arising from the Bragg peak. Prediction accuracy was evaluated using dose metrics for clinical target volume, planning target volume, and normal liver, 10% dose region volume assessment, visual examination, Dice similarity coefficient (DSC) for 10% dose region, and dose–volume histogram (DVH) analysis. DL models employing dose gradient-aware loss demonstrated reduced prediction errors in target volume dose metrics, achieved the lowest errors in 10% dose region volume when combined with U-Net (MAE: 35.4 cm3, RMSE: 51.3 cm3), attained the highest DSC (0.88 ± 0.05), showed the closest DVH agreement with clinical plans for both target structures and normal liver. A comprehensive evaluation consistently confirmed the superiority of dose gradient-aware loss across all metrics, demonstrating the importance of physics-informed, dose gradient-aware learning for accurate PBT dose distribution prediction. Particularly, DL models combining simple architectures with dose gradient-aware loss predicted doses that closely approximated clinical doses in PBT.
- 6 May 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (3) , 369-383
Open AccessDeep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions
In proton beam therapy (PBT) for hepatocellular carcinoma (HCC), deep learning (DL)-based dose prediction offers clinical value by providing immediate reference dose distributions as a guideline tool for treatment planners and enabling virtual PBT dose assessment at institutions lacking PBT facilities to support clinical decision-making. This study proposes a dose gradient-aware DL training approach and a beam arrangement-free framework that predicts dose distributions from computed tomography (CT) images and target/organs-at-risk structures without requiring beam arrangement inputs. Using data from 172 HCC patients, we systematically compared 20 DL models combining five architectures with four loss functions, including a novel dose gradient-aware loss capturing PBT-specific dose distribution characteristics arising from the Bragg peak. Prediction accuracy was evaluated using dose metrics for clinical target volume, planning target volume, and normal liver, 10% dose region volume assessment, visual examination, Dice similarity coefficient (DSC) for 10% dose region, and dose–volume histogram (DVH) analysis. DL models employing dose gradient-aware loss demonstrated reduced prediction errors in target volume dose metrics, achieved the lowest errors in 10% dose region volume when combined with U-Net (MAE: 35.4 cm3, RMSE: 51.3 cm3), attained the highest DSC (0.88 ± 0.05), showed the closest DVH agreement with clinical plans for both target structures and normal liver. A comprehensive evaluation consistently confirmed the superiority of dose gradient-aware loss across all metrics, demonstrating the importance of physics-informed, dose gradient-aware learning for accurate PBT dose distribution prediction. Particularly, DL models combining simple architectures with dose gradient-aware loss predicted doses that closely approximated clinical doses in PBT.
- Open Access
- 6 October 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 66 (6) , 682-688
Dosimetric effect of internal error correction on pubic bones in image-guided passive scattering proton therapy for prostate cancer
Image-guided passive scattering proton therapy (PSPT) has been widely adopted in Japan and worldwide, with substantial long-term clinical data supporting its efficacy in treating prostate cancer. However, as hypofractionated protocols become increasingly common, the impact of internal anatomical shifts on surrounding organs at risk (OARs) warrants renewed attention. The pubic bones, situated near the prostate, are often exposed to unintended high doses, especially during internal error correction based on fiducial marker alignment. This study retrospectively analyzed 30 patients with localized prostate cancer treated with PSPT using lateral opposed fields. Simulated isocenter shifts were applied anteriorly and inferiorly in 2-mm increments up to 10 mm to assess dose changes to the pubic bones. Dose-volume histogram metrics including V80%, V90% and V95% were evaluated. Pubic bones dose increased in both shift directions, with a more pronounced effect for anterior shifts, with a 10-mm anterior shift increasing V80% by 14.2 cc on average—2.4 times greater than inferior shifts. Dose elevation correlated strongly with the anatomical proximity between the clinical target volume and pubic bones (r > 0.66, P < 0.001). These results suggest that anterior correction in PSPT can cause substantial dose escalation to the pubic bones, potentially increasing the risk of insufficiency fractures. As extreme hypofractionation becomes more common, careful evaluation of pubic bones dose should be incorporated into treatment planning, alongside traditional OARs such as the rectum and bladder. Early replanning should be considered when persistent anterior displacement is observed to maintain patient safety and quality of life.
- 6 October 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 66 (6) , 682-688
Open AccessDosimetric effect of internal error correction on pubic bones in image-guided passive scattering proton therapy for prostate cancer
Image-guided passive scattering proton therapy (PSPT) has been widely adopted in Japan and worldwide, with substantial long-term clinical data supporting its efficacy in treating prostate cancer. However, as hypofractionated protocols become increasingly common, the impact of internal anatomical shifts on surrounding organs at risk (OARs) warrants renewed attention. The pubic bones, situated near the prostate, are often exposed to unintended high doses, especially during internal error correction based on fiducial marker alignment. This study retrospectively analyzed 30 patients with localized prostate cancer treated with PSPT using lateral opposed fields. Simulated isocenter shifts were applied anteriorly and inferiorly in 2-mm increments up to 10 mm to assess dose changes to the pubic bones. Dose-volume histogram metrics including V80%, V90% and V95% were evaluated. Pubic bones dose increased in both shift directions, with a more pronounced effect for anterior shifts, with a 10-mm anterior shift increasing V80% by 14.2 cc on average—2.4 times greater than inferior shifts. Dose elevation correlated strongly with the anatomical proximity between the clinical target volume and pubic bones (r > 0.66, P < 0.001). These results suggest that anterior correction in PSPT can cause substantial dose escalation to the pubic bones, potentially increasing the risk of insufficiency fractures. As extreme hypofractionation becomes more common, careful evaluation of pubic bones dose should be incorporated into treatment planning, alongside traditional OARs such as the rectum and bladder. Early replanning should be considered when persistent anterior displacement is observed to maintain patient safety and quality of life.
- 18 September 2024
- Published by Wiley in Medical Physics
- Vol. 51 (12) , 9250-9263
Long‐term beam output stability of an accelerator‐based boron neutron capture therapy system
Background: Accelerator‐based boron neutron capture therapy (AB‐BNCT) systems are becoming commercially available and are expected to be widely used in hospitals. To ensure the safety of BNCT, establishing a quality assurance (QA) program and properly managing the stability of the system are necessary. In particular, a high level of beam output stability is required to avoid accidents because beam output is a major factor in patient dose. However, no studies have analyzed the long‐term beam output stability of AB‐BNCT systems.Purpose: This study aimed to retrospectively analyze the long‐term stability of the beam output by statistical process control (SPC) based on the QA results over 3 years.Methods: The data analyzed are the results of daily QA (DQA) and weekly QA (WQA) in an AB‐BNCT system and were taken between June 2020 and September 2023. The evaluation of the stability of the beam output was based on the reaction rate between gold and neutrons calculated using the activation foil method using a gold foil. In DQA, which can be performed in a short time, the gold foil was applied directly to the beam irradiation aperture in air. In WQA, measurements were performed at the phantom surface, 2‐cm depth, and 6‐cm depth using a dedicated water phantom. The acquired data were retrospectively analyzed by individuals and a moving range chart (I‐MR chart), exponentially weighted moving average control chart (EWMA chart), and several process capability indexes (PCIs).Results: Over 99% of the DQA I‐MR chart results were within control limits, whereas the WQA I‐MR chart results showed that 1.8%, 4.1%, and 2.0% of the measurements exceeded the control limits at the surface, 2‐cm depth, and 6‐cm depth, respectively. The variation in the reaction rate of the gold foil before and after the replacement of the target was 1.0; however, the Cpmk of DQA and the 2‐ and 6‐cm depth WQAs between August 2021 and November 2022 in treatment course 2 were 0.83, 0.77, and 0.87, respectively, which were <1.0.Conclusions: The long‐term stability of beam output was confirmed using SPC in an AB‐BNCT system. The results of the control chart revealed no significant variation or drift in the beam output, and the quantitative evaluation using PCI revealed high stability. A routine QA program will enable us to provide safe BNCT.
- 18 September 2024
- Published by Wiley in Medical Physics
- Vol. 51 (12) , 9250-9263
Long‐term beam output stability of an accelerator‐based boron neutron capture therapy system
Background: Accelerator‐based boron neutron capture therapy (AB‐BNCT) systems are becoming commercially available and are expected to be widely used in hospitals. To ensure the safety of BNCT, establishing a quality assurance (QA) program and properly managing the stability of the system are necessary. In particular, a high level of beam output stability is required to avoid accidents because beam output is a major factor in patient dose. However, no studies have analyzed the long‐term beam output stability of AB‐BNCT systems.Purpose: This study aimed to retrospectively analyze the long‐term stability of the beam output by statistical process control (SPC) based on the QA results over 3 years.Methods: The data analyzed are the results of daily QA (DQA) and weekly QA (WQA) in an AB‐BNCT system and were taken between June 2020 and September 2023. The evaluation of the stability of the beam output was based on the reaction rate between gold and neutrons calculated using the activation foil method using a gold foil. In DQA, which can be performed in a short time, the gold foil was applied directly to the beam irradiation aperture in air. In WQA, measurements were performed at the phantom surface, 2‐cm depth, and 6‐cm depth using a dedicated water phantom. The acquired data were retrospectively analyzed by individuals and a moving range chart (I‐MR chart), exponentially weighted moving average control chart (EWMA chart), and several process capability indexes (PCIs).Results: Over 99% of the DQA I‐MR chart results were within control limits, whereas the WQA I‐MR chart results showed that 1.8%, 4.1%, and 2.0% of the measurements exceeded the control limits at the surface, 2‐cm depth, and 6‐cm depth, respectively. The variation in the reaction rate of the gold foil before and after the replacement of the target was 1.0; however, the Cpmk of DQA and the 2‐ and 6‐cm depth WQAs between August 2021 and November 2022 in treatment course 2 were 0.83, 0.77, and 0.87, respectively, which were <1.0.Conclusions: The long‐term stability of beam output was confirmed using SPC in an AB‐BNCT system. The results of the control chart revealed no significant variation or drift in the beam output, and the quantitative evaluation using PCI revealed high stability. A routine QA program will enable us to provide safe BNCT.
- Open Access
- 1 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14257
Analysis of respiratory‐induced motion trajectories of individual liver segments in patients with hepatocellular carcinoma
Purpose: To analyze the respiratory‐induced motion trajectories of each liver segment for hepatocellular carcinoma (HCC) to derive a more accurate internal margin and optimize treatment protocol selection.Materials and Methods: Ten‐phase‐gated four‐dimensional computed tomography (4DCT) scans of 14 patients with HCC were analyzed. For each patient, eight representative regions of interest (ROI) were delineated on each liver segment in all 10 phases. The coordinates of the center of gravity of each ROI were obtained for each phase, and then the respiratory motion in the left–right (LR), anteroposterior (AP), and craniocaudal (CC) directions was analyzed. Two sets of motion in each direction were also compared in terms of only two extreme phases and all 10 phases.Results: Motion of less than 5 mm was detected in 12 (86%) and 10 patients (71%) in the LR and AP directions, respectively, while none in the CC direction. Motion was largest in the CC direction with a maximal value of 19.5 mm, with significant differences between liver segment 7 (S7) and other segments: S1 (p < 0.036), S2 (p < 0.041), S3 (p < 0.016), S4 (p < 0.041), and S5 (p < 0.027). Of the 112 segments, hysteresis >1 mm was observed in 4 (4%), 2 (2%), and 15 (13%) in the LR, AP, and CC directions, respectively, with a maximal value of 5.0 mm in the CC direction.Conclusion: A significant amount of respiratory motion was detected in the CC direction, especially in S7, and S8. Despite the small effect of hysteresis, it can be observed specifically in the right lobe. Therefore, caution is required when using 4DCT to determine IM using only end‐inspiration and end‐expiration. Understanding the respiratory motion in individual liver segments can be helpful when selecting an appropriate treatment protocol.
- 1 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14257
Open AccessAnalysis of respiratory‐induced motion trajectories of individual liver segments in patients with hepatocellular carcinoma
Purpose: To analyze the respiratory‐induced motion trajectories of each liver segment for hepatocellular carcinoma (HCC) to derive a more accurate internal margin and optimize treatment protocol selection.Materials and Methods: Ten‐phase‐gated four‐dimensional computed tomography (4DCT) scans of 14 patients with HCC were analyzed. For each patient, eight representative regions of interest (ROI) were delineated on each liver segment in all 10 phases. The coordinates of the center of gravity of each ROI were obtained for each phase, and then the respiratory motion in the left–right (LR), anteroposterior (AP), and craniocaudal (CC) directions was analyzed. Two sets of motion in each direction were also compared in terms of only two extreme phases and all 10 phases.Results: Motion of less than 5 mm was detected in 12 (86%) and 10 patients (71%) in the LR and AP directions, respectively, while none in the CC direction. Motion was largest in the CC direction with a maximal value of 19.5 mm, with significant differences between liver segment 7 (S7) and other segments: S1 (p < 0.036), S2 (p < 0.041), S3 (p < 0.016), S4 (p < 0.041), and S5 (p < 0.027). Of the 112 segments, hysteresis >1 mm was observed in 4 (4%), 2 (2%), and 15 (13%) in the LR, AP, and CC directions, respectively, with a maximal value of 5.0 mm in the CC direction.Conclusion: A significant amount of respiratory motion was detected in the CC direction, especially in S7, and S8. Despite the small effect of hysteresis, it can be observed specifically in the right lobe. Therefore, caution is required when using 4DCT to determine IM using only end‐inspiration and end‐expiration. Understanding the respiratory motion in individual liver segments can be helpful when selecting an appropriate treatment protocol.
- Open Access
- 30 May 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (9) , e14043
Dosimetric effect of six degrees of freedom couch top with rotational setup error corrections in proton therapy
Purpose: To investigate the dosimetric effect of six degrees of freedom (6DoF) couch top with rotational corrections in proton therapy (PT).Methods: The water equivalent thickness (WET) was measured using a proton beam with a 6DoF couch top and patient immobilization base plate (PIBP) placed in front of a motorized water phantom. The accuracy verification was performed with the beam axis set perpendicular to the 6DoF couch top and tilted in 10° steps from 10° to 30°. Up to 3° rotational correction may be added during the actual treatment to correct the rotational setup error on our system. The measured and calculated values using the treatment planning system were compared. Additionally, the effect of the 3° difference was evaluated using actual measurements concerning each angle on the proton beam range.Results: The WET of the 6DoF couch top and PIBP were 8.5 ± 0.1 mm and 6.8 ± 0.1 mm, respectively. The calculation and the actual measurement at each angle agreed within 0.2 mm at the maximum. A maximum difference of approximately 0.6 mm was confirmed when tilted at 3° following 30° with the 6DoF couch top plus PIBP.Conclusions: The dosimetric effect of the 6DoF couch top with rotational corrections in PT differs depending on the incidence angle on the couch top, and it increased with the increased oblique angle of incidence. However, the effect on the range was as small as 0.6 mm at the maximum. The amount of rotational correction, the angle of incidence of the beam, and the effect of rotational corrections on the proton beam range may differ depending on the structure of the couch top. Therefore, sufficient prior confirmation, and subsequent periodical quality assurance management are important.
- 30 May 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (9) , e14043
Open AccessDosimetric effect of six degrees of freedom couch top with rotational setup error corrections in proton therapy
Purpose: To investigate the dosimetric effect of six degrees of freedom (6DoF) couch top with rotational corrections in proton therapy (PT).Methods: The water equivalent thickness (WET) was measured using a proton beam with a 6DoF couch top and patient immobilization base plate (PIBP) placed in front of a motorized water phantom. The accuracy verification was performed with the beam axis set perpendicular to the 6DoF couch top and tilted in 10° steps from 10° to 30°. Up to 3° rotational correction may be added during the actual treatment to correct the rotational setup error on our system. The measured and calculated values using the treatment planning system were compared. Additionally, the effect of the 3° difference was evaluated using actual measurements concerning each angle on the proton beam range.Results: The WET of the 6DoF couch top and PIBP were 8.5 ± 0.1 mm and 6.8 ± 0.1 mm, respectively. The calculation and the actual measurement at each angle agreed within 0.2 mm at the maximum. A maximum difference of approximately 0.6 mm was confirmed when tilted at 3° following 30° with the 6DoF couch top plus PIBP.Conclusions: The dosimetric effect of the 6DoF couch top with rotational corrections in PT differs depending on the incidence angle on the couch top, and it increased with the increased oblique angle of incidence. However, the effect on the range was as small as 0.6 mm at the maximum. The amount of rotational correction, the angle of incidence of the beam, and the effect of rotational corrections on the proton beam range may differ depending on the structure of the couch top. Therefore, sufficient prior confirmation, and subsequent periodical quality assurance management are important.