Effect of attenuation mismatches in time of flight PET reconstruction
Open Access
- 26 February 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (8) , 085009
Abstract
While the pursuit of better time resolution in positron emission tomography (PET) is rapidly evolving, little work has been performed on time of flight (TOF) image quality at high time resolution in the presence of modelling inconsistencies. This works focuses on the effect of using the wrong attenuation map in the system model, causing perturbations in the reconstructed radioactivity image. Previous work has usually considered the effects to be local to the area where there is attenuation mismatch, and has shown that the quantification errors in this area tend to reduce with improved time resolution. This publication shows however that errors in the PET image at a distance from the mismatch increase with time resolution. The errors depend on the reconstruction algorithm used. We quantify the errors in the hypothetical case of perfect time resolution for maximum likelihood reconstructions. In addition, we perform reconstructions on simulated and patient data. In particular, for respiratory-gated reconstructions from a wrong attenuation map, increased errors are observed with improved time resolutions in areas close to the lungs (e.g. from 13.3% in non-TOF to up to 20.9% at 200 ps in the left ventricle).Keywords
All Related Versions
Funding Information
- GlaxoSmithKline (BIDS3000030921)
This publication has 33 references indexed in Scilit:
- Respiratory-Induced Errors in Tumor Quantification and Delineation in CT Attenuation-Corrected PET Images: Effects of Tumor Size, Tumor Location, and Respiratory Trace: A Simulation Study Using the 4D XCAT PhantomMolecular Imaging and Biology, 2013
- Time-of-flight PET data determine the attenuation sinogram up to a constantPhysics in Medicine & Biology, 2012
- Physical Performance of the new hybrid PET/CT Discovery-690Medical Physics, 2011
- PET/CT artifactsClinical Imaging, 2011
- Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?Physics in Medicine & Biology, 2010
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- PET/CT scanner instrumentation, challenges, and solutionsRadiologic Clinics of North America, 2004
- Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinogramsIEEE Transactions on Medical Imaging, 1999
- A Single Scatter Simulation Technique for Scatter Correction in 3D PET1996