Perfusion microbioreactor system with permeable membranes to monitor bacterial growth
Authors:
- Franciele Flores VitFVFranciele Flores Vit
- Aline Furtado OliveiraAOAline Furtado Oliveira
- Daniel Andrés Osorio RodríguezDRDaniel Andrés Osorio Rodríguez
- Hernandes Faustino de CarvalhoHernandes Faustino de Carvalho
- Marcelo LancellottiMLMarcelo Lancellotti
- Lucimara Gaziola de la TorreLTLucimara Gaziola de la Torre
- 26 November 2018
- journal article
- research article
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 94 (3) , 712-720
Abstract
BACKGROUND: Microfluidics offers itself as a potential platform for optimizing microbial growth in different substrate concentrations using a single assay. The aim of this study was to construct a reversible microfluidic device for monitoring the bacterial growth in chambers with different substrate concentrations with its respective technical triplicates. The convective concentration gradient generator (CCG) system was constructed with three inlets for solutions with different concentrations that distributed them to the sequential cultivation chambers (CCs). A perfusion microbioreactor system (PM) was constructed using a commercial polydimethylsiloxane (PDMS) sheet and glass, with an adapted semi‐permeable membrane system to constrain the cells within the CC. Cell growth of a fluorescent Escherichia coli JM109 was monitored by fluorescence microscope with time‐lapse technique.RESULTS: The growth profile of E. coli with different streptomycin concentrations and its specific growth rates (µx) in the microfluidics device (µx of 0.0088 and 0.0092 h−1) were compared in batch cultivations, which show no significant difference between the two methods. In addition, the half maximal inhibitory concentration (IC50) values indicate that continuous perfusion surpasses consumption of the tested drug.CONCLUSION: The results demonstrate the efficiency of the microfluidic device for cell cultivation and its applicability in industrial biotechnology, allowing rapid screening of multiple parameters. © 2018 Society of Chemical IndustryKeywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2015/26701-0)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (33003017034P8)
This publication has 38 references indexed in Scilit:
- Bacterial flagella explore microscale hummocks and hollows to increase adhesionProceedings of the National Academy of Sciences, 2013
- Microtopographic Patterns Affect Escherichia coli Biofilm Formation on Poly(dimethylsiloxane) SurfacesLangmuir, 2011
- Bacterial Chemotaxis in Linear and Nonlinear Steady Microfluidic GradientsNano Letters, 2010
- Engineering Hydrogels as Extracellular Matrix MimicsNanomedicine, 2010
- Microfluidics for bacterial chemotaxisIntegrative Biology, 2010
- Flow-Based Microfluidic Device for Quantifying Bacterial Chemotaxis in Stable, Competing GradientsApplied and Environmental Microbiology, 2009
- Simultaneous generation of chemical concentration and mechanical shear stress gradients using microfluidic osmotic flow comparable to interstitial flowLab on a Chip, 2009
- Application of microfluidic gradient chip in the analysis of lung cancer chemotherapy resistanceJournal of Pharmaceutical and Biomedical Analysis, 2009
- Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated deviceNature Biotechnology, 2002
- Diffusion of Glucose and Glucitol in Microporous and Mesoporous Silicate/Aluminosilicate CatalystsIndustrial & Engineering Chemistry Research, 1996