Influence of High Myopia on Outcomes of iStent Inject W Implantation Combined with Cataract Surgery up to 24 Months of Follow-Up
Authors:
- Yuto ShiotaniYSYuto Shiotani
- Takeshi YoshidaTYTakeshi Yoshida
- Sota YoshimotoSYSota Yoshimoto
- Keigo SugisawaKSKeigo Sugisawa
- Shintaro YasudaSYShintaro Yasuda
- Motohisa OhnoMOMotohisa Ohno
- Ryu TeramatsuRTRyu Teramatsu
- Hiroki IemuraHIHiroki Iemura
- Yusaku ShibataYSYusaku Shibata
- Kyoko Ohno-MatsuiKOKyoko Ohno-Matsui
Open Access
- 5 February 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1265
Abstract
Background: The purpose of this study was to evaluate the 2-year postoperative outcomes of iStent inject W implantation combined with phacoemulsification, with a specific focus on comparing results between high myopia (HM) and non-high myopia (non-HM) eyes. Methods: In this retrospective study, subjects were divided into HM and non-HM groups using an axial length cut-off of 26.0 mm. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications, surgical success rates, and postoperative complications. Surgical success was defined as a decrease in glaucoma medical therapy of ≥1 medication without an increase in IOP, or a postoperative IOP ≤ 21 mmHg with a ≥20% reduction. Changes from baseline were analyzed up to 24 months postoperatively. Results: The non-HM group achieved a significant IOP reduction at all postoperative time points. The HM group showed no significant postoperative IOP reduction except at 3 months. The mean number of medications significantly decreased from baseline to 24 months in two groups. The cumulative surgical success rate at 24 months was 48.6% in the non-HM group, whereas it was significantly lower at 19.4% in the HM group (p = 0.038). No significant difference in the incidence of postoperative complications was observed between the groups. Conclusions: The IOP-lowering efficacy of iStent inject W implantation combined with phacoemulsification appeared limited in eyes with HM. These results may suggest the need for careful patient selection and clinical judgment when considering iStent inject W implantation in this population.Keywords
This publication has 57 references indexed in Scilit:
- The effect of axial length on the short-term outcomes of cataract surgery combined with ab interno trabeculotomyGraefe's Archive for Clinical and Experimental Ophthalmology, 2023
- Which is More Effective and Safer? Comparison of Propensity Score-Matched Microhook Ab Interno Trabeculotomy and iStent InjectOphthalmology and Therapy, 2023
- Establishment of novel therapy to reduce progression of myopia in rats with experimental myopia by fibroblast transplantation on scleraJournal of Tissue Engineering and Regenerative Medicine, 2017
- Influence of high myopia on outcomes of trabeculectomy with mitomycin C in patients with primary open-angle glaucomaJapanese Journal of Ophthalmology, 2016
- Scleral Mechanisms Underlying Ocular Growth and Myopia2015
- The Pathophysiology and Treatment of GlaucomaJAMA, 2014
- Ocular Biometric Parameters Associated With Intraocular Pressure Reduction After Cataract Surgery in Normal EyesAmerican Journal of Ophthalmology, 2013
- Reduction of Intraocular Pressure and Glaucoma ProgressionArchives of Ophthalmology (1950), 2002
- Open Angle Glaucoma, Ocular Hypertension, Low-Tension Glaucoma, and RefractionArchives of Ophthalmology (1950), 1982
- Aqueous Pathways in Some Cases of GlaucomaAmerican Journal of Ophthalmology, 1956