Takeshi Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takeshi Yoshida has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Kyoko Ohno-Matsui
Department of Ophthalmology, Institute of Science Tokyo, Tokyo, Japan
15 shared publicationsSota Yoshimoto
Department of Ophthalmology, Institute of Science Tokyo, Tokyo, Japan
8 shared publicationsMotohisa Ohno
Department of Ophthalmology, Institute of Science Tokyo, Tokyo, Japan
7 shared publicationsShintaro Yasuda
Department of Ophthalmology, Institute of Science Tokyo, Tokyo, Japan
6 shared publicationsKeigo Sugisawa
Department of Ophthalmology, Institute of Science Tokyo, Tokyo, Japan
5 shared publications- Kyoko Ohno-Matsui
Department of Ophthalmology and Visual Science, Institute of Science, Tokyo, Japan
5 shared publications
Latest Publications
- Open Access
- 25 February 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Deep Learning–Based Prediction of Visual Field Mean Deviation from Numeric OCT Data in Glaucoma
The purpose is to evaluate whether numeric optical coherence tomography (OCT) data can predict Humphrey Visual Field Analyzer (HFA) 30–2 mean deviation (MD) using deep learning (DL). In this retrospective study, 1200 eyes (432 glaucoma and 768 normal eyes) that underwent spectral-domain OCT (12 × 9.0-mm high-density scanning) and Humphrey Field Analyzer (HFA) 30–2 testing on the same day were analyzed. Pixel-wise retinal thickness numeric values were directly exported from OCT and input into eight deep learning models, including five convolutional neural networks (ResNet50, VGG16, InceptionV3, EfficientNetB0, and DenseNet121) and three vision transformers (ViT, DeiT, and BEiT). Two distinct prediction tasks were performed: (1) a regression task to predict continuous HFA MD values and (2) a classification task to discriminate VF deterioration at predefined MD thresholds. For the regression task, model performance was assessed using standard regression metrics, and agreement between predicted and measured MD values was additionally evaluated using the Bland–Altman analysis. For the classification task, model performance was evaluated using threshold-based discrimination metrics. Both tasks were evaluated using fivefold cross-validation. The mean age was 63.3 ± 21.5 years, axial length 25.43 ± 1.33 mm, and baseline MD − 5.32 ± 4.33 dB. Among all models, InceptionV3 achieved the best performance, with a mean absolute error of 3.36 dB and a coefficient of determination of 0.53. In classification analyses at clinically relevant MD thresholds, CNN-based models achieved high discrimination performance across early, moderate, and severe visual field loss. We developed an accurate and explainable DL system directly leveraging raw numeric OCT thickness data to predict HFA 30–2 MD values; this predictive DL approach may enhance diagnosis of glaucoma.
- 25 February 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Open AccessDeep Learning–Based Prediction of Visual Field Mean Deviation from Numeric OCT Data in Glaucoma
The purpose is to evaluate whether numeric optical coherence tomography (OCT) data can predict Humphrey Visual Field Analyzer (HFA) 30–2 mean deviation (MD) using deep learning (DL). In this retrospective study, 1200 eyes (432 glaucoma and 768 normal eyes) that underwent spectral-domain OCT (12 × 9.0-mm high-density scanning) and Humphrey Field Analyzer (HFA) 30–2 testing on the same day were analyzed. Pixel-wise retinal thickness numeric values were directly exported from OCT and input into eight deep learning models, including five convolutional neural networks (ResNet50, VGG16, InceptionV3, EfficientNetB0, and DenseNet121) and three vision transformers (ViT, DeiT, and BEiT). Two distinct prediction tasks were performed: (1) a regression task to predict continuous HFA MD values and (2) a classification task to discriminate VF deterioration at predefined MD thresholds. For the regression task, model performance was assessed using standard regression metrics, and agreement between predicted and measured MD values was additionally evaluated using the Bland–Altman analysis. For the classification task, model performance was evaluated using threshold-based discrimination metrics. Both tasks were evaluated using fivefold cross-validation. The mean age was 63.3 ± 21.5 years, axial length 25.43 ± 1.33 mm, and baseline MD − 5.32 ± 4.33 dB. Among all models, InceptionV3 achieved the best performance, with a mean absolute error of 3.36 dB and a coefficient of determination of 0.53. In classification analyses at clinically relevant MD thresholds, CNN-based models achieved high discrimination performance across early, moderate, and severe visual field loss. We developed an accurate and explainable DL system directly leveraging raw numeric OCT thickness data to predict HFA 30–2 MD values; this predictive DL approach may enhance diagnosis of glaucoma.
- 19 February 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 35 (6) , 401-410
Short-term Efficacy and Safety of Preserflo MicroShunt Surgery in Glaucoma Eyes With and Without High Myopia
Précis: This study demonstrated that the Preserflo MicroShunt effectively lowered intraocular pressure in eyes with open angle glaucoma; however, the reduction was less pronounced in highly myopic eyes than in nonhighly myopic eyes. Purpose: To compare surgical outcomes between eyes with high myopia (HM) and non-HM in open angle glaucoma (OAG) and to identify risk factors for surgical success. Methods: This retrospective study included 52 eyes (41 patients) with OAG that underwent Preserflo MicroShunt (PMS) implantation and were followed for 6 months. Eyes were categorized by axial length (AL) into non-HM (AL ≤26.5 mm) and HM (AL >26.5 mm) groups. Surgical success was defined as a ≥20% intraocular pressure (IOP) reduction and postoperative IOP ≤18 mm Hg (criterion A), ≤15 mm Hg (criterion B), or ≤12 mm Hg (criterion C) without increased glaucoma medications. Kaplan-Meier analysis compared cumulative success rates, and Cox regression identified risk factors for failure. Results: Mean AL was 24.01±1.18 mm in non-HM and 30.26±2.30 mm in HM eyes ( P P P =0.037 and P =0.034), with no differences after 1 month. At 6 months, surgical success was significantly lower in HM eyes for criteria A and C ( P =0.009 and P =0.044). AL was the critical risk factor for surgical failure. No significant differences were found in adverse events between groups. Conclusions: PMS implantation effectively lowered IOP in both groups; however, surgical success was reduced in HM eyes, suggesting decreased short-term surgical stability.
- 19 February 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 35 (6) , 401-410
Short-term Efficacy and Safety of Preserflo MicroShunt Surgery in Glaucoma Eyes With and Without High Myopia
Précis: This study demonstrated that the Preserflo MicroShunt effectively lowered intraocular pressure in eyes with open angle glaucoma; however, the reduction was less pronounced in highly myopic eyes than in nonhighly myopic eyes. Purpose: To compare surgical outcomes between eyes with high myopia (HM) and non-HM in open angle glaucoma (OAG) and to identify risk factors for surgical success. Methods: This retrospective study included 52 eyes (41 patients) with OAG that underwent Preserflo MicroShunt (PMS) implantation and were followed for 6 months. Eyes were categorized by axial length (AL) into non-HM (AL ≤26.5 mm) and HM (AL >26.5 mm) groups. Surgical success was defined as a ≥20% intraocular pressure (IOP) reduction and postoperative IOP ≤18 mm Hg (criterion A), ≤15 mm Hg (criterion B), or ≤12 mm Hg (criterion C) without increased glaucoma medications. Kaplan-Meier analysis compared cumulative success rates, and Cox regression identified risk factors for failure. Results: Mean AL was 24.01±1.18 mm in non-HM and 30.26±2.30 mm in HM eyes ( P P P =0.037 and P =0.034), with no differences after 1 month. At 6 months, surgical success was significantly lower in HM eyes for criteria A and C ( P =0.009 and P =0.044). AL was the critical risk factor for surgical failure. No significant differences were found in adverse events between groups. Conclusions: PMS implantation effectively lowered IOP in both groups; however, surgical success was reduced in HM eyes, suggesting decreased short-term surgical stability.
- Open Access
- 5 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1265
Influence of High Myopia on Outcomes of iStent Inject W Implantation Combined with Cataract Surgery up to 24 Months of Follow-Up
Background: The purpose of this study was to evaluate the 2-year postoperative outcomes of iStent inject W implantation combined with phacoemulsification, with a specific focus on comparing results between high myopia (HM) and non-high myopia (non-HM) eyes. Methods: In this retrospective study, subjects were divided into HM and non-HM groups using an axial length cut-off of 26.0 mm. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications, surgical success rates, and postoperative complications. Surgical success was defined as a decrease in glaucoma medical therapy of ≥1 medication without an increase in IOP, or a postoperative IOP ≤ 21 mmHg with a ≥20% reduction. Changes from baseline were analyzed up to 24 months postoperatively. Results: The non-HM group achieved a significant IOP reduction at all postoperative time points. The HM group showed no significant postoperative IOP reduction except at 3 months. The mean number of medications significantly decreased from baseline to 24 months in two groups. The cumulative surgical success rate at 24 months was 48.6% in the non-HM group, whereas it was significantly lower at 19.4% in the HM group (p = 0.038). No significant difference in the incidence of postoperative complications was observed between the groups. Conclusions: The IOP-lowering efficacy of iStent inject W implantation combined with phacoemulsification appeared limited in eyes with HM. These results may suggest the need for careful patient selection and clinical judgment when considering iStent inject W implantation in this population.
- 5 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1265
Open AccessInfluence of High Myopia on Outcomes of iStent Inject W Implantation Combined with Cataract Surgery up to 24 Months of Follow-Up
Background: The purpose of this study was to evaluate the 2-year postoperative outcomes of iStent inject W implantation combined with phacoemulsification, with a specific focus on comparing results between high myopia (HM) and non-high myopia (non-HM) eyes. Methods: In this retrospective study, subjects were divided into HM and non-HM groups using an axial length cut-off of 26.0 mm. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications, surgical success rates, and postoperative complications. Surgical success was defined as a decrease in glaucoma medical therapy of ≥1 medication without an increase in IOP, or a postoperative IOP ≤ 21 mmHg with a ≥20% reduction. Changes from baseline were analyzed up to 24 months postoperatively. Results: The non-HM group achieved a significant IOP reduction at all postoperative time points. The HM group showed no significant postoperative IOP reduction except at 3 months. The mean number of medications significantly decreased from baseline to 24 months in two groups. The cumulative surgical success rate at 24 months was 48.6% in the non-HM group, whereas it was significantly lower at 19.4% in the HM group (p = 0.038). No significant difference in the incidence of postoperative complications was observed between the groups. Conclusions: The IOP-lowering efficacy of iStent inject W implantation combined with phacoemulsification appeared limited in eyes with HM. These results may suggest the need for careful patient selection and clinical judgment when considering iStent inject W implantation in this population.
- Open Access
- 7 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 962
Current Topics in OCT Applications in Vitreoretinal Surgery
Optical coherence tomography (OCT) is an indispensable tool in modern ophthalmology, where it is used in prior examinations, among various instruments, to assess macular or vitreoretinal diseases. Pathological macular/retinal conditions are almost always examined and evaluated with OCT before and after treatment. Vitreoretinal surgery is one of the most effective treatment options for vitreoretinal diseases. OCT data collected during the treatment of these diseases has accumulated, leading to the reporting of a variety of novel biomarkers and valuable findings related to OCT usage. Recent substantial developments in technology have brought ultra-high-resolution spectral domain/swept source OCT, ultra-widefield OCT, and OCT angiography into the retinal clinic. Here, we review the basic development of the instrument and general applications of OCT in ophthalmology. Subsequently, we provide up-to-date OCT topics based on observations in vitreoretinal surgery.
- 7 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 962
Open AccessCurrent Topics in OCT Applications in Vitreoretinal Surgery
Optical coherence tomography (OCT) is an indispensable tool in modern ophthalmology, where it is used in prior examinations, among various instruments, to assess macular or vitreoretinal diseases. Pathological macular/retinal conditions are almost always examined and evaluated with OCT before and after treatment. Vitreoretinal surgery is one of the most effective treatment options for vitreoretinal diseases. OCT data collected during the treatment of these diseases has accumulated, leading to the reporting of a variety of novel biomarkers and valuable findings related to OCT usage. Recent substantial developments in technology have brought ultra-high-resolution spectral domain/swept source OCT, ultra-widefield OCT, and OCT angiography into the retinal clinic. Here, we review the basic development of the instrument and general applications of OCT in ophthalmology. Subsequently, we provide up-to-date OCT topics based on observations in vitreoretinal surgery.
- 15 July 2025
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 34 (10) , 762-770
Efficacy of Filtration Surgery and Risk Factors for Central Visual Field Deterioration in Highly Myopic Eyes With Open Angle Glaucoma
Précis: This study demonstrates the effectiveness of filtration surgery in preserving the central visual field in eyes showing open angle glaucoma with high myopia, highlighting the necessity of intraocular pressure reduction ≥30% for optimal outcomes. Purpose: To evaluate the efficacy of filtration surgery in preserving the central visual field (VF) in eyes with open angle glaucoma (OAG) and high myopia (HM) and identify postoperative intraocular pressure (IOP) targets and factors associated with targeted IOP reduction. Methods: This retrospective cohort study included 55 eyes (48 patients) with OAG and HM who underwent filtration surgery and were followed up for minimum 3 years. Preoperative and postoperative IOP values, mean deviation (MD) values, and MD slopes from Humphrey 10-2 VF tests were assessed. Participants were categorized according to the postoperative MD slope (>−0.5 dB/y or ≤−0.5 dB/y) to evaluate surgical success, defined as IOP reduction of ≥20%, ≥30%, or ≥40% from baseline. Predictors of targeted IOP reduction were identified. Results: Significant postoperative IOP reductions were observed at all time points (PP=0.001). Eyes with MD slope ≤−0.5 dB/year had a longer axial length (AL; P=0.048), more needling procedures (P=0.003), and higher postoperative IOP at 1 and 2 years (P−0.5 dB/year (P=0.006, 0.003), with no significant difference for IOP reduction ≥20% (P=0.087). To achieve postoperative MD slope >−0.5 dB/year, minimum 30% IOP reduction was required. If AL was >28.01 mm, 40% IOP reduction was required. AL and needling procedure frequency were significantly associated with IOP reduction ≥30% (odds ratio=1.79 and 2.26; P=0.018 and 0.039, respectively). Conclusions: Substantial IOP reduction is essential for preserving the central visual field in eyes with OAG and HM, particularly those with AL ≥28.01 mm. Longer AL and frequent needling procedures increase the surgical failure risk.
- 15 July 2025
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 34 (10) , 762-770
Efficacy of Filtration Surgery and Risk Factors for Central Visual Field Deterioration in Highly Myopic Eyes With Open Angle Glaucoma
Précis: This study demonstrates the effectiveness of filtration surgery in preserving the central visual field in eyes showing open angle glaucoma with high myopia, highlighting the necessity of intraocular pressure reduction ≥30% for optimal outcomes. Purpose: To evaluate the efficacy of filtration surgery in preserving the central visual field (VF) in eyes with open angle glaucoma (OAG) and high myopia (HM) and identify postoperative intraocular pressure (IOP) targets and factors associated with targeted IOP reduction. Methods: This retrospective cohort study included 55 eyes (48 patients) with OAG and HM who underwent filtration surgery and were followed up for minimum 3 years. Preoperative and postoperative IOP values, mean deviation (MD) values, and MD slopes from Humphrey 10-2 VF tests were assessed. Participants were categorized according to the postoperative MD slope (>−0.5 dB/y or ≤−0.5 dB/y) to evaluate surgical success, defined as IOP reduction of ≥20%, ≥30%, or ≥40% from baseline. Predictors of targeted IOP reduction were identified. Results: Significant postoperative IOP reductions were observed at all time points (PP=0.001). Eyes with MD slope ≤−0.5 dB/year had a longer axial length (AL; P=0.048), more needling procedures (P=0.003), and higher postoperative IOP at 1 and 2 years (P−0.5 dB/year (P=0.006, 0.003), with no significant difference for IOP reduction ≥20% (P=0.087). To achieve postoperative MD slope >−0.5 dB/year, minimum 30% IOP reduction was required. If AL was >28.01 mm, 40% IOP reduction was required. AL and needling procedure frequency were significantly associated with IOP reduction ≥30% (odds ratio=1.79 and 2.26; P=0.018 and 0.039, respectively). Conclusions: Substantial IOP reduction is essential for preserving the central visual field in eyes with OAG and HM, particularly those with AL ≥28.01 mm. Longer AL and frequent needling procedures increase the surgical failure risk.
- Open Access
- 2 June 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (6) , 74
Interplay Between γ-Zone Peripapillary Atrophy and Optic Disc Parameters in Central Visual Field Impairment in Highly Myopic Eyes
The purpose of this study was to investigate the association between the development of glaucoma-like central visual field (VF) defects and γ-zone peripapillary atrophy (γPPA) in eyes with high myopia (HM). This retrospective study measured γPPA length, prelaminar tissue (PLT) thickness, and lamina cribrosa (LC) defects' width in HM eyes with central VF defects by swept-source optical coherence tomography (OCT). The central VF was assessed by using the Humphrey Field Analyzer 10-2 program, and average light sensitivity in the papillomacular bundle region (C1 region) and mean deviation (MD) values were calculated. Interactions among the central VF and structural abnormalities were analyzed using correlation tests and linear regression. Forty-five eyes from 45 patients were included. PLT thickness was positively associated with light sensitivity in the C1 region and MD values, whereas γPPA was associated only with MD values. LC defects showed no association with either the C1 region or MD values. LC defects' width was negatively correlated with γPPA length. Stratified analysis showed that in the group with γPPA length ≥763 µm, PLT thickness was positively associated, and γPPA length was negatively associated with the C1 region and MD values. No such associations were found when the γPPA length was <763 µm. The association between LC defects with central VF remained nonsignificant. Our findings identified γPPA length and PLT thickness as risk factors of glaucoma-like central VF defects in HM, particularly when γPPA length exceeds 763 µm. We suggest that HM eyes with larger γPPA and thinner PLT should be paid special attention for early detection of central VF defects.
- 2 June 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (6) , 74
Open AccessInterplay Between γ-Zone Peripapillary Atrophy and Optic Disc Parameters in Central Visual Field Impairment in Highly Myopic Eyes
The purpose of this study was to investigate the association between the development of glaucoma-like central visual field (VF) defects and γ-zone peripapillary atrophy (γPPA) in eyes with high myopia (HM). This retrospective study measured γPPA length, prelaminar tissue (PLT) thickness, and lamina cribrosa (LC) defects' width in HM eyes with central VF defects by swept-source optical coherence tomography (OCT). The central VF was assessed by using the Humphrey Field Analyzer 10-2 program, and average light sensitivity in the papillomacular bundle region (C1 region) and mean deviation (MD) values were calculated. Interactions among the central VF and structural abnormalities were analyzed using correlation tests and linear regression. Forty-five eyes from 45 patients were included. PLT thickness was positively associated with light sensitivity in the C1 region and MD values, whereas γPPA was associated only with MD values. LC defects showed no association with either the C1 region or MD values. LC defects' width was negatively correlated with γPPA length. Stratified analysis showed that in the group with γPPA length ≥763 µm, PLT thickness was positively associated, and γPPA length was negatively associated with the C1 region and MD values. No such associations were found when the γPPA length was <763 µm. The association between LC defects with central VF remained nonsignificant. Our findings identified γPPA length and PLT thickness as risk factors of glaucoma-like central VF defects in HM, particularly when γPPA length exceeds 763 µm. We suggest that HM eyes with larger γPPA and thinner PLT should be paid special attention for early detection of central VF defects.
- 7 May 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (3) , 432-441
Evaluation of changes in retinal light sensitivity thresholds in the early postoperative days after trabeculectomy using microperimetry
Purpose To investigate early postoperative changes in retinal light sensitivity at the foveal and paramacular points in open angle glaucoma patients. Study design Retrospective cohort study. Methods Twenty-four eyes undergoing trabeculectomy were analyzed. Retinal light sensitivity thresholds were measured using microperimetry both before and 7 days after surgery. Linear regression analysis identified factors affecting postoperative sensitivity changes. We also evaluated the correlation between changes in the threshold of retinal light sensitivity at the foveal and paramacular points. Results Intraocular pressure significantly decreased postoperatively. The mean threshold values of retinal light sensitivity following surgery showed no statistically significant changes compared with preoperative values across all eyes. Specifically, the mean threshold values increased in 4 eyes, decreased in 2, and remained stable in 18. Upon analyzing each examination point, 71.8% eyes exhibited stability, 12.8% showed a decrease of less than −6 dB, and 15.4% demonstrated an improvement of more than +6 dB in threshold values of retinal light sensitivity post-surgery. Changes in retinal light sensitivity at most paramacular points were found to be independent of those at the fovea. Excessive IOP reduction was identified as a significant risk factor for central visual field impairment. Conclusions Localized changes in retinal light sensitivity thresholds can vary in the early postoperative period following trabeculectomy, highlighting the need to monitor localized retinal function to better understand its impact on visual outcomes.
- 7 May 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (3) , 432-441
Evaluation of changes in retinal light sensitivity thresholds in the early postoperative days after trabeculectomy using microperimetry
Purpose To investigate early postoperative changes in retinal light sensitivity at the foveal and paramacular points in open angle glaucoma patients. Study design Retrospective cohort study. Methods Twenty-four eyes undergoing trabeculectomy were analyzed. Retinal light sensitivity thresholds were measured using microperimetry both before and 7 days after surgery. Linear regression analysis identified factors affecting postoperative sensitivity changes. We also evaluated the correlation between changes in the threshold of retinal light sensitivity at the foveal and paramacular points. Results Intraocular pressure significantly decreased postoperatively. The mean threshold values of retinal light sensitivity following surgery showed no statistically significant changes compared with preoperative values across all eyes. Specifically, the mean threshold values increased in 4 eyes, decreased in 2, and remained stable in 18. Upon analyzing each examination point, 71.8% eyes exhibited stability, 12.8% showed a decrease of less than −6 dB, and 15.4% demonstrated an improvement of more than +6 dB in threshold values of retinal light sensitivity post-surgery. Changes in retinal light sensitivity at most paramacular points were found to be independent of those at the fovea. Excessive IOP reduction was identified as a significant risk factor for central visual field impairment. Conclusions Localized changes in retinal light sensitivity thresholds can vary in the early postoperative period following trabeculectomy, highlighting the need to monitor localized retinal function to better understand its impact on visual outcomes.
- 25 November 2024
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (4) , 1089-1103
Retromode Infrared Scanning Laser Ophthalmoscopy in Vogt-Koyanagi-Harada Disease
Purpose This study examined six patients with Vogt–Koyanagi–Harada (VKH) disease using retromode infrared scanning laser ophthalmoscopy (RMI-SLO). Methods We conducted a single-center retrospective review of the medical records of six patients diagnosed with VKH disease. The RMI-SLO images were compared to those obtained using color fundus photography, optical coherence tomography (OCT), and dye-based retinal angiography. Results In the acute phase of VKH disease, RMI-SLO revealed pseudo-three-dimensional (3D) regions and wavy patterns. These observations corresponded to the areas of serous retinal detachment (sRD) and choroidal folds identified on OCT. Notably, the detection of pseudo-3D regions by RMI-SLO proved to be more effective than color fundus photography in identifying sRDs. Hyper-reflective lines inside the sRDs were observed in the RMI-SLO images and were consistent with the fibrinous membranes observed in the OCT images. The hyper-reflective choroidal vasculature in RMI-SLO images was notably absent, a finding like the fuzzy pattern of large stromal choroidal vessels observed in indocyanine green angiography images. Following steroid treatment, these abnormal findings reverted to normal. Conclusions RMI-SLO imaging could serve as an alternative option for both pre- and post-treatment assessments in VKH disease. Moreover, it has the potential to reduce the need for retinal angiography. Key Messages What is known Optical coherence tomography (OCT) and indocyanine green angiography (ICGA) are essential for the diagnosis of Vogt–Koyanagi–Harada (VKH) disease. However, it is difficult to visualize a wide area of the fundus with OCT, and ICGA carries risks of allergic reactions or shock. What is new Retromode infrared scanning laser ophthalmoscopy (RMI-SLO) can demonstrate pseudo-three-dimensional regions and wavy patterns corresponding to serous retinal detachment and choroidal folds in the acute stage of VKH disease. Hyper-reflective choroidal vasculature was absent in the acute stage of VKH disease on RMI-SLO and may correlate with choroidal thickening. RMI-SLO could be an alternative option for the assessment of VKH disease and has the potential to reduce the need for dye-based retinal angiography.
- 25 November 2024
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (4) , 1089-1103
Retromode Infrared Scanning Laser Ophthalmoscopy in Vogt-Koyanagi-Harada Disease
Purpose This study examined six patients with Vogt–Koyanagi–Harada (VKH) disease using retromode infrared scanning laser ophthalmoscopy (RMI-SLO). Methods We conducted a single-center retrospective review of the medical records of six patients diagnosed with VKH disease. The RMI-SLO images were compared to those obtained using color fundus photography, optical coherence tomography (OCT), and dye-based retinal angiography. Results In the acute phase of VKH disease, RMI-SLO revealed pseudo-three-dimensional (3D) regions and wavy patterns. These observations corresponded to the areas of serous retinal detachment (sRD) and choroidal folds identified on OCT. Notably, the detection of pseudo-3D regions by RMI-SLO proved to be more effective than color fundus photography in identifying sRDs. Hyper-reflective lines inside the sRDs were observed in the RMI-SLO images and were consistent with the fibrinous membranes observed in the OCT images. The hyper-reflective choroidal vasculature in RMI-SLO images was notably absent, a finding like the fuzzy pattern of large stromal choroidal vessels observed in indocyanine green angiography images. Following steroid treatment, these abnormal findings reverted to normal. Conclusions RMI-SLO imaging could serve as an alternative option for both pre- and post-treatment assessments in VKH disease. Moreover, it has the potential to reduce the need for retinal angiography. Key Messages What is known Optical coherence tomography (OCT) and indocyanine green angiography (ICGA) are essential for the diagnosis of Vogt–Koyanagi–Harada (VKH) disease. However, it is difficult to visualize a wide area of the fundus with OCT, and ICGA carries risks of allergic reactions or shock. What is new Retromode infrared scanning laser ophthalmoscopy (RMI-SLO) can demonstrate pseudo-three-dimensional regions and wavy patterns corresponding to serous retinal detachment and choroidal folds in the acute stage of VKH disease. Hyper-reflective choroidal vasculature was absent in the acute stage of VKH disease on RMI-SLO and may correlate with choroidal thickening. RMI-SLO could be an alternative option for the assessment of VKH disease and has the potential to reduce the need for dye-based retinal angiography.
- Open Access
- 2 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1411
Blue Wavelength of Scanning Laser Ophthalmoscope Potentially Detects Arteriosclerotic Lesions in Diabetic Retinopathy
(1) Background: The fundus examination is one of the best and popular methods in the assessment of vascular status in the human body. Direct viewing of retinal vessels by ophthalmoscopy has been utilized in judging hypertensive change or arteriosclerosis. Recently, fundus imaging with the non-mydriatic scanning laser ophthalmoscope (SLO) has been widely used in ophthalmological clinics since it has multimodal functions for optical coherence tomography or angiography with contrast agent dye. The purpose of this study was to examine the utility in detecting arteriosclerosis of retinal vessels in SLO images; (2) Methods: Both color and blue standard field SLO images of eyes with diabetic retinopathy (DR) were examined retrospectively. Retinal arteriosclerosis in color SLO images was graded according to the Scheie classification. Additionally, characteristics of retinal arterioles in blue SLO images were identified and examined for their relevance to arteriosclerosis grades, stages of DR or general complications; (3) Results: Relative to color fundus images, blue SLO images showed distinct hyper-reflective retinal arterioles against a monotone background. Irregularities of retinal arterioles identified in blue SLO images were frequently observed in the eyes of patients with severe arteriosclerosis (Grade 3: 79.0% and Grade 4: 81.8%). Furthermore, the findings on arterioles were more frequently associated with the eyes of DR patients with renal dysfunction (p < 0.05); (4) Conclusions: While color SLO images are equally as useful in assessing retinal arteriosclerosis as photography or ophthalmoscopy, the corresponding blue SLO images show arteriosclerotic lesions with high contrast in a monotone background. Retinal arteriosclerosis in eyes of advanced grades or advanced DR frequently show irregularities of retinal arterioles in the blue images. The findings of low, uneven, or discontinuous attenuation were easier to find in blue than in color SLO images. Consequently, blue SLO images can show pathological micro-sclerosis in retinal arterioles and are potentially one of the safe and practical methods for the vascular assessment of diabetic patients.
- 2 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1411
Open AccessBlue Wavelength of Scanning Laser Ophthalmoscope Potentially Detects Arteriosclerotic Lesions in Diabetic Retinopathy
(1) Background: The fundus examination is one of the best and popular methods in the assessment of vascular status in the human body. Direct viewing of retinal vessels by ophthalmoscopy has been utilized in judging hypertensive change or arteriosclerosis. Recently, fundus imaging with the non-mydriatic scanning laser ophthalmoscope (SLO) has been widely used in ophthalmological clinics since it has multimodal functions for optical coherence tomography or angiography with contrast agent dye. The purpose of this study was to examine the utility in detecting arteriosclerosis of retinal vessels in SLO images; (2) Methods: Both color and blue standard field SLO images of eyes with diabetic retinopathy (DR) were examined retrospectively. Retinal arteriosclerosis in color SLO images was graded according to the Scheie classification. Additionally, characteristics of retinal arterioles in blue SLO images were identified and examined for their relevance to arteriosclerosis grades, stages of DR or general complications; (3) Results: Relative to color fundus images, blue SLO images showed distinct hyper-reflective retinal arterioles against a monotone background. Irregularities of retinal arterioles identified in blue SLO images were frequently observed in the eyes of patients with severe arteriosclerosis (Grade 3: 79.0% and Grade 4: 81.8%). Furthermore, the findings on arterioles were more frequently associated with the eyes of DR patients with renal dysfunction (p < 0.05); (4) Conclusions: While color SLO images are equally as useful in assessing retinal arteriosclerosis as photography or ophthalmoscopy, the corresponding blue SLO images show arteriosclerotic lesions with high contrast in a monotone background. Retinal arteriosclerosis in eyes of advanced grades or advanced DR frequently show irregularities of retinal arterioles in the blue images. The findings of low, uneven, or discontinuous attenuation were easier to find in blue than in color SLO images. Consequently, blue SLO images can show pathological micro-sclerosis in retinal arterioles and are potentially one of the safe and practical methods for the vascular assessment of diabetic patients.
- Open Access
- 1 January 2024
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 15 (1) , 335-342
Temporal Protrusion of the Optic Disc Implicated in Central Visual Field Abnormalities in High Myopia: Two Case Reports
Introduction: Severe central visual field defects are frequently observed in highly myopic eyes. This report details 2 cases of central visual field defects in individuals with high myopia, characterized by an unusual temporal protrusion of the optic disc, a feature not previously documented. Case Presentation: Two patients, a 54-year-old man and a 65-year-old woman, were diagnosed with high myopia in their left eyes, displaying an outward protrusion of the optic disc toward the macula. Swept-source optical coherence tomography revealed a focal lamina cribrosa defect at the temporal edge of the protruding optic disc, corresponding to the papillomacular bundle area of retinal nerve fibers, which exhibited thinning around the focal lamina cribrosa defect. Visual field examination indicated a central visual field defect in the affected eyes, which pattern corresponded to the papillomacular bundle responsible area. Conclusion: The emergence of a temporal protrusion in the optic disc may lead to a focal lamina cribrosa defect, resulting in a central visual field defect in highly myopic eyes. This distinctive optic disc feature may constitute a critical risk factor for a central visual field defect. Hence, optic disc protrusion in high myopia warrants attention, necessitating careful ophthalmic examinations for central visual field defects.
- 1 January 2024
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 15 (1) , 335-342
Open AccessTemporal Protrusion of the Optic Disc Implicated in Central Visual Field Abnormalities in High Myopia: Two Case Reports
Introduction: Severe central visual field defects are frequently observed in highly myopic eyes. This report details 2 cases of central visual field defects in individuals with high myopia, characterized by an unusual temporal protrusion of the optic disc, a feature not previously documented. Case Presentation: Two patients, a 54-year-old man and a 65-year-old woman, were diagnosed with high myopia in their left eyes, displaying an outward protrusion of the optic disc toward the macula. Swept-source optical coherence tomography revealed a focal lamina cribrosa defect at the temporal edge of the protruding optic disc, corresponding to the papillomacular bundle area of retinal nerve fibers, which exhibited thinning around the focal lamina cribrosa defect. Visual field examination indicated a central visual field defect in the affected eyes, which pattern corresponded to the papillomacular bundle responsible area. Conclusion: The emergence of a temporal protrusion in the optic disc may lead to a focal lamina cribrosa defect, resulting in a central visual field defect in highly myopic eyes. This distinctive optic disc feature may constitute a critical risk factor for a central visual field defect. Hence, optic disc protrusion in high myopia warrants attention, necessitating careful ophthalmic examinations for central visual field defects.